background image

INSTALLATION WARNINGS:

BEFORE COMMENCING INSTALLATION ISOLATE YOUR MAINS ELECTRIC SUPPLY

Read the instructions care fully before starting the installation process and keep them for future reference. This product must be 
installed by a qualified electrician. This product should be installed in accordance with the relevant sections of the building regulations 
code, and the current edition of the IEE Wiring Regulations (BS 7671:Requirements for electrical installations) and appropriate 
statutory regulations.

Ensure all connections are made correctly and the cables are not stressed and all terminal screws are tight firmly holding the cables
All Sockets must be earthed and the leads must be correctly sleeved.

Installation

1. Remove the glass panel 

of 

a socket: Using a small flat screw-
driver remove the front cover by 
placing the screw driver in the 
location notch on the bottom part of 

the cover and twist to unclip the 
cover.

2. 

Ensure the backbox is secure in the wall.

3.

 Strip back cable sheath and trim the wires so no excess wire 

is pertruding out of the terminal.

4. 

Ensure there is a green/yellow insulation sleave on the bare 

earth wire.

5. 

Ensure the wires are connected to the corrert terminal. see 

diagram overleaf. 

RED or BROWN WIRE 

to  terminal marked ‘ 

L

 ’

BLACK or BLUEWIRE

 to  terminal marked ‘ 

N

 ’

GREEN/YELLOW

to terminal marked ‘    ’

6. 

Check all the connections are firmly in place and the screws 

are tightened.

7. 

Taking care not to knock, pinch or trap any of the cables 

insert the socket back in to the backbox

8. 

Align the screw holes on the socket and backbox and tighten 

until the socket is firmly seated and does not move.

9. 

Align the glass surround on the socket and push firmly until it 

clicks into place.

   

Wiring diagrams

twist to remove 

INSTRUCTION MANUAL

RTS2000
Plug sockets

The completed installation should be tested in accordance with the current IEE Wiring

Regulations by a qualified electrician.

Ensure that all electrical connections are correct and fully secured and that the product is screwed securely to its mounting box before
turning the mains electricity supply on.

To prevent fire hazard do not exceedthe maximum rated current of the socket.

13A 250V

13A 250V

2 Gang 13A Switched Socket

13A 250V

1 Gang 13A Switched Socket

12.10

Retrotouch, PO Box 1099, Worth, Crawley, RH10 OAD 

T: 01293 230407  F: 01293 471444 [email protected]  www.retrotouch.co.uk  

Reviews: