INSTALLATION, OPERATION & MAINTENANCE MANUAL
SAFETY INSTRUCTIONS
Read all instructions before using the RetroAire
Single Motor PTAC. Install or locate this unit only
in accordance with these instructions. Use this
unit only for its intended use as described in this
manual.
Check the rating plate on the RetroAire Single Motor
PTAC before installation to make certain the voltage
shown is the same as the electric supply to the unit.
The RetroAire Single Motor PTAC must be
connected only to a properly grounded electrical
supply. Do not fail to properly ground this unit.
Turn off the electrical supply before servicing the
RetroAire Single Motor PTAC.
Do not use the RetroAire Single Motor PTAC if it
has damaged wiring, is not working properly, or
has been damaged or dropped.
When turning the selector switch on the RC/RH30
for mode of operation, it is very important to make
sure the switch position is
“SEATED”
directly on
a mode of operation
(clicks into position)
.
Do not
mistakenly place between two positions.
This can
result in a potential fan failure while the system is
in a cooling or heating operation. A fan failure could
result in the unit overheating (smoke) in an electric
heating mode, or freezing coil in a cooling mode.
[Save These Instructions]
This manual is intended as an aid to qualified service
personnel for proper installation, operation, and
maintenance of the RetroAire Single Motor Packaged
Terminal Air Conditioner (PTAC). Read these instructions
thoroughly and carefully before attempting installation or
operation. Failure to follow these instructions may result
in improper installation, operation, service, or
maintenance, possibly resulting in fire, electrical shock,
property damage, personal injury, or death.
TO THE INSTALLER
(1) Retain this manual and warranty for future reference.
(2) Before leaving the premises, review this manual to be
sure the unit has been installed correctly and run the
unit for one complete cycle to make sure it functions
properly.
To obtain technical service or warranty assistance
during or after the installation of this unit, contact
your local representative. Visit our website
www.retroaire.com
for a local representative
listing. For further assistance call 1-800-228-9364.
When calling for assistance, please have the
following information ready:
• Model Number_________________________
• Serial Number_________________________
• Date of Installation______________________
!
!
Recognize this symbol as an indication
of important safety information
SINGLE MOTOR PACKAGED TERMINAL AIR CONDITIONERS
P/N# 240003989, Rev. 1.5 [02/05]
Shipping Damage MUST be Reported to the Carrier IMMEDIATELY!!!
Examine the exterior. Remove cover and examine compressor and piping for signs of damage.
!
!
DANGER
Do not use the RetroAire Single Motor PTAC with
any electrical supply voltage other than the one
listed on the rating plate.
Check the rating plate on the unit for the correct
voltage rating. Failure to use the correct voltage
may result in death, serious bodily injury or property
damage. If you have any questions or doubts,
consult the factory before installing this unit.