7. WARNINGS & LIMITATIONS

7.1. GENERAL INSTRUCTIONS

 

BEFORE USING RESQTEC EQUIPMENT, BE AWARE OF THE FOLLOWING:

• Resqtec equipment is designed for rescue/salvage operations only and may not be used for industrial purposes.

• Do not try to perform tasks that exceed the specifications of the particular product. The specifications clearly define the product capabilities. 

 

    Use a more powerful product from the Resqtec series if the situation occurs.

Summary of Contents for Pow'rench 1000

Page 1: ...USER MANUAL POW RENCH ENGLISH ORIGINAL RESQTEC USER MANUAL WWW RESQTEC COM...

Page 2: ...n 07 4 4 Dis connecting square drives 08 4 5 Operating the product 09 4 6 Adjusting the power 11 4 7 Precise tightening 12 5 SPECIFICATIONS 14 5 1 Technical specifications 14 5 1 1 SI system data 14 5...

Page 3: ...properly trained by the Authority having jurisdiction and using the equipment for its intended purposes only The following safety precautions must be observed at all times UNTRAINED USE OF RESQTEC EQU...

Page 4: ...maximum service all accessories such as offsets adapters and extensions used in conjunction with the Pow rench must be those specifically designed for Pow rench use as provided by Resqtec Likewise sq...

Page 5: ...to assist firefighters USAR teams and other rescue workers with the various rescue applications they encounter We are confident that the design of this product will enable those working in these envi...

Page 6: ...OW RENCH Series DM072K04 3 PRODUCT RANGE 3 1 PRODUCTS ACCESSORIES ARTICLE NUMBER ITEM DESCRIPTION USAGE RESTRICTIONS 9310 0010 Pow rench 625 50 See chapter 4 8 9310 0020 Pow rench 750 See chapter 4 8...

Page 7: ...ND DO NOT USE DAMAGED EQUIPMENT UNDER ANY CIRCUMSTANCE In general we distinguish a couple of different types of operations Dis connecting square drives Operating the product Adjusting the power Precis...

Page 8: ...the Pow rench to the impact socket or to different offsets and extensions The pins slip in and out easily and are held in place by friction Select the required square drive Connect the offset to the P...

Page 9: ...t with the Pow rench See chapter 4 4 Place the Pow rench and the connected square drive on the nut or bolt that needs to be fastened The nut or bolt is now fastened 1 2 4 Rotate clockwise or reciproca...

Page 10: ...the Pow rench See chapter 4 4 Place the Pow rench and the connected square drive on the nut that needs to be unfastened The nut or bolt can now be removed by hand 1 2 4 Rotate anticlockwise or recipr...

Page 11: ...ion number of the indicator in the slotted side of the product handle THE POWER OUTPUT INCREASES AS THE SETTING NUMBER IS INCREASED IT IS RECOMMENDED THAT THE LOWEST POWER SETTING THAT WILL DO THE JOB...

Page 12: ...Generally it takes one more impact to regain the specific torque value than it does to loosen the nut For instance if it takes 10 impacts to loosen the nut it will generally take 11 impacts to regain...

Page 13: ...The degree of impact produced by the Pow rench is dependent on the amount of resistance encountered Therefore anything which directly or indirectly affects the amount of resistance encountered also af...

Page 14: ...mm Head width 42 1 mm Handle length 305 mm Max pull on handle 17 7 kg POW RENCH 750 DATA Max torque 1085 Nm Weight 5 kg Dimensions 456 x 101 x 116 mm 10 mm Size of square drive 19 1 mm Head radius 50...

Page 15: ...d width 1 21 32 Handle length 12 Max pull on handle 39 lbs POW RENCH 750 DATA Max torque 800 ft lb Weight 11 lbs Dimensions 17 7 8 x 4 x 4 5 8 3 8 Size of square drive 3 4 Head radius 2 Head width 2 H...

Page 16: ...16 USER MANUAL POW RENCH RESQTEC Manual POW RENCH Series DM072K04 5 2 TECHNICAL DRAWINGS 5 2 1 SI SYSTEM DATA 5 2 2 IMPERIAL SYSTEM DATA...

Page 17: ...TION ADDITIONAL INFORMATION 1 Check the product s handle and side plates for cracks and or other signs of structural damage Visually check for cracks and or damage If any cracks or other structural da...

Page 18: ...dle and side plates for cracks and or other signs of structural damage Visually check for damage If any cracks or other structural damage to the product is discovered contact your Resqtec distributor...

Page 19: ...our distributor supplier can advise you on this and or attend to the annual maintenance on a contract basis if desired STRUCTURALLY DAMAGED AND OR BROKEN EQUIPMENT MUST NEVER BE USED DURING RESCUE OPE...

Page 20: ...20 USER MANUAL POW RENCH RESQTEC Manual POW RENCH Series DM072K04 6 4 LUBRICATION CHARTS MODEL 750 MODEL 1000...

Page 21: ...Store the equipment in a dry well ventilated area 6 6 DECOMISSIONING RECYCLING The various parts can be re used at the end of their service life Consult your distributor supplier for further informat...

Page 22: ...ARE OF THE FOLLOWING Resqtec equipment is designed for rescue salvage operations only and may not be used for industrial purposes Do not try to perform tasks that exceed the specifications of the part...

Page 23: ...R ONE OF THE RESQTEC OFFICES Symptom Solution The product fails to develop maximum torque Make sure the product is sufficiently lubricated For details please see chapter 6 Make sure the spring is prop...

Page 24: ...r Resqtec distributor supplier WARRANTY IS ONLY VALID IF THE REGULATIONS AND RESTRICTIONS AS DESCRIBED IN THE USER MANUAL APPLICABLE ON THE USED PRODUCT S ARE UNDERSTOOD AND FOLLOWED AND IF THE MAINTE...

Page 25: ...iled information and as we constantly improve our equipment please check the latest specification sheet This manual is based on and refers to current production models only Resqtec accepts no liabilit...

Page 26: ...Duin 82 2163 HC Lisse the Netherlands T 31 0 252 419002 F 31 0 252 411794 E info resqtec com I www resqtec com USA office 300 Forge Way Suite 2 Rockaway New Jersey 07866 T 1 973 627 4646 F 1 973 627 4...

Page 27: ...USER MANUAL POW RENCH RESQTEC Zumro B V Meer en Duin 82 2163 HC Lisse the Netherlands T 31 0 252 419002 F 31 0 252 411794 E info resqtec com WWW RESQTEC COM...

Reviews: