ResponseLink MDT-122 User Manual Download Page 2

2

 

DE2295U 

 

2. SPECIFICATIONS

2. SPECIFICATIONS

2. SPECIFICATIONS

2. SPECIFICATIONS

    

Transmission Type:

 Radio Frequency (RF) 

RF frequency (MHz): 

433.92 

Transmitter’s ID Code:

 28-bit ID, Code Secure

TM 

Modulation type: 

pulse width modulation 

Overall Message Length: 

66 bit 

Alarm Messages

: Tilt activated, pull-cord disconnected, Panic 

alarm, each with separate ID 

Power Source: 

3.6 V, Lithium battery, size 1/2 AA / 1.2 Ah, 

(Tadiran TL-2150 or equivalent.)  

Current Consumption:

 15

µ

A standby, 10mA (operation)  

Battery Life Expectancy:

 Up to 3 years (with regular use) 

Battery Supervision:

 Battery test every hour  

Operating temperature:

 0

°

C to 49

°

C (32

°

F to 120

°

F) 

Dimensions 

(H x W x D)

:

 120 x 52 x 36 mm (4-3/4 x 2-1/16 x 1-5/16 in.)  

  With Holster

-

3

:

 140 x 77 x 50 mm (5-7/16 x 3-1/16 x 1-15/16 in.) 

Housing:

 3mm ABS plastic box, weather proof

 

Weight: 

Man-down -138 g (4.9 Oz.), Holster-3  - 30 g (1.05 Oz.)  

Color: 

Body - dark gray, buttons - brown, pull cord - black

 

Compliance with Std.:

 FCC Part 15 

Accessories: 

Light weight water-resistant carry pouch Holster-3. 

    Metal 

belt 

clip. 

    Pull-cord 

with 

pin 

and 

cloth 

clip. 

 

 

3. FUNCTIONAL DESCRIPTION

3. FUNCTIONAL DESCRIPTION

3. FUNCTIONAL DESCRIPTION

3. FUNCTIONAL DESCRIPTION    

3.1 Visual and Audible Warning Timing 

A built-in tilt sensor activates the unit when the unit is tilted down 
by more than 60

°

 (see figure 3). When the unit is activated, it 

enters a pre-alarm state for 30 seconds. This period enables the 
user to return the transmitter to the normal (vertical) position, to 
prevent an unintentional alarm transmission.  

During this period an audible warning is sounded by the buzzer 
and a visual warning is indicated (by the internal LED). The 
buzzer’s sound can be disabled by using an internal buzzer’s 
switch (see table 1). Figure 4 presents the timing diagram.  

Prealarm time:

15 short beeps

+ 1 long beep

Buzzer

sound

0

30

t (sec.)

MDT-122 is returned

to normal position

before 30 sec.

0

30

MDT-122 is returned to

normal position after 30 sec.

ON

OFF

Part of

prealarm time

Transmission

and LED

0

30

t (sec.)

Alarm

Alarm

restore

ON

OFF

 

Figure 4 - MDT-122  Functional Timing Diagram

 

3.2 Low Battery Voltage Indication  

The battery is automatically tested every hour, under load 
condition. If the battery voltage is low, “low battery” message is 
sent every transmission. 
 In addition, when the battery voltage is low, the LED blinks while 
pressing the left or right push-button switch.  

3.3 External Buttons Functions

 

(see fig. 2)

  

A.

 

Left or Right push-buttons 

When left and right push-buttons are pressed, panic alarm is 
transmitted.

 

 

B.

 

Tilt ON-OFF Slide Switch 

By using this switch, the user can disable the tilt sensor 
function (this is necessary when a guard goes off duty or 
performs such activities that can activate the transmitter and 
create a false alarm). When the unit is delivered from the 
factory, the switch is in OFF position. 

C.

 

Temp Tilt Off Push-Button Switch 

The push-button is located at the top of the unit. It is used for 

temporary

 disabling (5 minutes) of the tilt sensor function, 

when it is desired. To re-enable tilt function before the 5 
minutes delay expires, the tilt ON-OFF slide switch should be 
switched to OFF position and then to ON again. 

3.4 Pull-Cord Function 

(see par. 1C)

 

3.5 Internal DIP Switches Functions 

Table 1 - Internal DIP Switches Functions

 

Switch Description  Default 

1 Buzzer 

ON/OFF 

ON 

Pull-cord option  

ON 

3 (not 

used) 

OFF 

4 (not 

used) 

OFF 

(For future use) 

Tilt alarm delay ON/OFF (*) 

ON 

*    

Tilt Alarm Delay Enable/Disable

 

30 second pre-alarm delay enabled/disabled. 

If the “tilt alarm delay” DIP switch is set to OFF position (no 
delay) the tilt pre-alarm DIP switch position is disregarded. 

3.6 Buzzer Functions 

The internal buzzer sounds, as shown in figure 4 and in the 
following situations: 

A. 

When someone is tampering / stops tampering with the unit. 

 

B. 

Whenever the internal DIP switch setting is changed.

 