Intr
oduction
When connected to the RE3000 Contr
ol Unit, the
RE5000AD may only be used to communicate one
message phrase associated with the Alarm Activation -
(usually relating to an Intruder Alarm Condition).
This message phrase will be made up of the common
phrase O and message phrase A. Message phrases B,
C and D will not be used in this instance.
THE FOLLOWING MUST BE READ IN CONJUNCTION
WITH THE RE5000AD (TSD1+) INSTALLATION AND
OPERATING INSTRUCTIONS SUPPLIED AND THE
RE3000 INSTALLATION AND OPERATING MANUAL.
CONNECTING THE RE5000AD TO THE
RE3000 CONTROL UNIT.
1.
Disconnect all power (Mains and Back-up Battery)
from the Control Unit before making any connections.
2. Connect the 4 core cable supplied with the Dialler to
the Control Unit as shown.
3. Ensure that all cabling is connected correctly. Cut
back or insulate any unused cable cores to prevent
short circuits.
4. Connect the Telephone Cable to the Dialler - (see
Dialler Installation Instructions).
5. Reconnect power to the Control Unit and proceed to
programme and test the Dialler in accordance with
the Dialler Operators Manual.
Loudspeaker
Tamper
Switch
Microphone
Set Trig polarity Link to '–'
for negative trigger to suit
RE3000CU trigger output
Telephone Line
Connection Terminals
Factory
Restart Pins
Red
Black
Yellow
Terminals inside
RE3000 Control Unit
NO 1
C 2
NC 3
Power (–) 4
Power (+) 5
4-Core Cable
(Blue wire not used)
Install link wire between
terminals 2 and 4
Red
Black
Yellow
Factory Restart
0/P1
0V
+12V
TRIGGER
POLARITY
A B A1 B1
TELEPHONE CONNECTIONS
TAMP ABORT C B A
TRIG INPUT
TSD1
+
Using the RE5000AD with a
RE3000
System Contr
ol Unit
W
A_08.04
CA2000AD
W
ireless Alarms.
1
7 Church Road, Great Bookham, Surrey KT23 3PG
Telephone: 01372 450960 E-mail: [email protected] www.wireless-alarms.net
0359
RADIO DEVICES FOR USE IN THE UK
HELPLINE
If you need help, just dial for
expert technical support
0
1372 450960
(Lines open 9.00am to 6.00pm, Monday to Friday).