Intr
oduction
When connected to the RE5000 Contr
ol Unit, the
RE5000AD may be used to communicate up to three
separate message phrases (usually relating to Intruder,
Fire and Medical Alert conditions). The Dialler Tamper
Switch may be connected to Zone 6 on the RE5000CU
if tamper protection is required.
The Communicator Interface Cable connection supplied
with the RE5000 Control Unit allows simple connection
between the Control Unit and Dialler.
THE FOLLOWING MUST BE READ IN CONJUNCTION
WITH THE RE5000AD (TSD1+) INSTALLATION AND
OPERATING INSTRUCTIONS SUPPLIED AND THE
RE5000 INSTALLATION AND OPERATING MANUAL.
CONNECTING THE RE5000AD TO
THE RE5000 CONTROL UNIT.
1.
Disconnect all power (Mains and Back-up Battery)
from the Control Unit before making any connections.
2. Plug the Interface Cable into the Control Unit plug
and connect the lead to the Dialler as shown.
3. Ensure that all cabling is connected correctly and that
all unused cores of the Interface Cable are cut back or
insulated to prevent accidental short circuits.
4. Connect the Telephone Cable to the Dialler - (see
Dialler Installation Instructions).
5. Reconnect power to the Control Unit and proceed to
programme and test the Dialler in accordance with
the Dialler Operators Manual.
Note:
If your RE5000CU is supplied with an 8-Cor
e
interface cable, please call our Technical
Helpline for connection advice.
Loudspeaker
Tamper
Switch
Microphone
Set Trig Polarity
Link to '+' for
negative trigger
to suit RE5000CU
trigger output
Telephone Line
Connection Terminals
Factory
Restart Pins
Factory Restart
0/P1
0V
+12V
TRIGGER
POLARITY
A B A1 B1
TELEPHONE CONNECTIONS
TAMP ABORT C B A
TRIG INPUT
TSD1
+
Optional Dialler Tamper Connection
To Zone 6 Hard Wired Zone Input
on RE5000CU
9-Core Interface Cable
Red +12V
Blue
Grey
Brown
Orange
Yellow
Green
Mauve
White
AC Power
Failure
– 0V
Arm
Disarm
Low Batt
Intruder
Fire
Medical Alert/
Personal Attack
Control Unit
Terminal Block
Plug-in Connector to Control Unit PCB
N.O.
COM
N.C.
V+
GRD
Zone 6
Siren
Charge
Tamper
Communicator
Interface Cable
Connection
Connections for 9-Cor
e Interface Cable
9
CORE
Using the RE5000AD with a
RE5000
System Contr
ol Unit
Installation and Operating Instr
uctions