E-20
CAUTION
:
Germicidal Light Radiation
Hazard!
Never look directly at UV lamp or
place face directly on outlet grill.
Direct exposure to germicidal light
can cause temporary or chronic
damage to your eyesight, or even
blindness.
Always unplug the unit before
cleaning, servicing or replacing the
UV lamp.
CARE AND MAINTENANCE
Photo catalytic Filter and UV Lamp
1.
Photo catalytic filter is permanent, never needs replacing. When there is dust on it, clean the dust off using a
vacuum cleaner dusting brush. Do not wash it in water.
2.
When the "UV LAMP" indicator light on the control panel flashes yellow, it is time to replace the UV lamp (UV-C
germicidal lamp). After removing the UV light blocker, gently rotate the lamp a quarter turn in either direction
until it unlocks from the socket. Pull the pins out the sides of the socket, one end at a time.
After replacement of activated carbon filter or UV lamp, be sure to
press Filter Reset Button (RESET1 Button) or UV Lamp Reset Button
(RESET2 Button) on the remote control for 5 times.
Once the Reset Buttons have been activated, you will hear a beep
sound that means that the unit has been reset and the FILTER LIFE or
UV LAMP indicator lights will stop flashing.
Helpful Hints
Place the activated carbon filter so that the wire
screen side is facing the cell!
DO NOT place the carbon fiber side facing the
cell or in front of the cell!
It may cause fire!
Carbon filter
side
Wire screen
side
Replacing UV lamp
Photo catalytic filter
UV-C
germicidal lamp
Correct
Wrong