AO3/AO3W/AO5/AO5W  Series 

Medical Oxygen Concentrator

User Manual

Official micro channel code

specialized

 

manufacturer

 

of

 

respiratory equipment

www.rms-care.com

EC    

REP

Part NO.233010002     Rev 3.0  3/20/15

  

Manufacture: Shenyang RMS Medical Tech Co.,Ltd
Address: No. 8-1, Gaoge Road, Hunnan New District, Shenyang, China
Tel:  0086-024-23782895-8001
Fax: 0086-024-23782895-8008

KINGSMEAD SERVICE LIMITED
145-157 St John Street, London, EC1V 4PY (UK)                     
TEL:044-20-7193 9159

Summary of Contents for AO3 Series

Page 1: ...piratory equipment www rms care com EC REP Part NO 233010002 Rev 3 0 3 20 15 Manufacture Shenyang RMS Medical Tech Co Ltd Address No 8 1 Gaoge Road Hunnan New District Shenyang China Tel 0086 024 23782895 8001 Fax 0086 024 23782895 8008 KINGSMEAD SERVICE LIMITED 145 157 St John Street London EC1V 4PY UK TEL 044 20 7193 9159 ...

Page 2: ...e Warranty Instructions Section 7 Troubleshooting Guide Troubleshooting Alarms Appendix A EMC Information 04 04 05 06 06 07 07 07 07 07 08 08 09 10 11 11 11 11 13 14 15 15 15 16 16 17 18 Drip Proof Equipment IP21 NO smoking Serial Number Indicating its conformity with the medical devices directive 93 42 EEC The 0917 is the number of notified body Proper disposal of equipment according to local law...

Page 3: ...ction 1 Special Notes Please read all instructions before using Important information is highlighted by these terms 1 1 Warnings Never use aerosol sprays or flammable anesthetics near the equipment If the equipment has a damaged cord or plug if it is not working properly if it has been dropped or damaged or if it has been submersed in water do not use and call a qualified technician for examinatio...

Page 4: ...ency so it may cause interference if using the portable communication equipments near the device 1 4 Intended Use Medical oxygen concentrator Model AO3 AO3W AO5 AO5W used for separating oxygen from air EUT not intended to be used for emergency treatment and patient who has serious carbon monoxide poisoning cannot use this device Section 2 Packaging And Handling 2 1 Unpacking Check for any obvious ...

Page 5: ...test Oxygen Concentration Testing Circuit Breaker Power Switch Power Socket Filter Device Tag LCD Screen Control Buttons Caste Handle Warning Tag Oxygen Outlet Inlet Filter Window Compressed Air Output Humidifier Bottle Section 3 Features 3 1 Parts and Functions Flow Regulating Button Filter Oxygen Outlet Control Buttons Respiratory Medical Solutions 09 08 ...

Page 6: ...backpressure is 0 and the rated flow is 3L min giving a 7kpa backpressure can make the flow being 2 8 L min If the power network isn t stable the power voltage fluctuate over 10 please use it after installing a voltage stabilizer Make sure the environment nearby dry ventilated no dust and any other caustic gas no strong electromagnetic interference This device can be used normally below the height...

Page 7: ...en tube and check the power cord using it continuously after troubleshooting Press On Off button to use it continuously after the external power regaining End of use Press the On Off button to stop the device working after finished using and turn off the power cord Take down the power line if you don t often use it 5 4 Operating Panel and LCD Screen Start Stop Plus Key Minus Key Timer Key Mode Oxy...

Page 8: ...e The damage caused by human error fault operation konck moving liquid infiltration etc The damage by natural disasters or accidents Other accessories not listed for warranty Oxygen Concentration 0 1 2 3 4 This time 00 00 h min Timer off h min Flow L min 5 5 Operating Method Operation interface Display working mode alarm information oxygen concentration oxygen flow present service time timing time...

Page 9: ...ndicator flashing Continuous Alarm Concentrator not operating Press start stop the alarm stops Call service provider indicator flashing Continuous Alarm start stop the alarm stops Call service provider Concentrator not operating The red low pressure indicator flashing Continuous Alarm Press start stop the alarm stops Call service provider Concentrator not operating The red hign pressure indicator ...

Page 10: ...3 3 Vrms 150 kHz to 80 MHZ outside ISM bandsa 3 V m 80 MHz to 2 5 GHz 3V 3V m Portable and mobile RF communications equipment should be used no closer to any part of the XXXXXXX including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Guidance and manufacturer s declaration electromagnetic immunity This device is intended...