background image

RE118 Interlogix

® 

Compatible Trident

 Environmental Sensor

Trident 

is an integrated environmental sensor. It detects water 

and reports extreme temperature conditions. 

Features

•  Titanium probes for unmatched corrosion immunity 

•  IP67 rated waterproof enclosure

•  GORE® vent equalizes enclosure pressure

•  5 year warranty

Enroll

 by placing the panel into wireless enrollment mode and 

then sending an enrollment signal from the sensor. The flood 

signal is enrolled by default. To Enroll the freeze and heat 

zones, remove the sensor cover. Use a wire or a paper clip 

to short the desired outer terminal to the center terminal, 

shorting one terminal at a time.

DL ID Configuration

•  Flood

 zone is the serial number shown on the device

•  Freeze 

zone is the serial number with last digit 

replaced with a 1

•  Heat

 zone is the serial number with last digit replace 

with a 2.

  

Install 

by placing the sensor in the location requiring water or air 

temperature detection. If desired, the wall clip can be used to 

secure the Trident sensor. 

Optional Wall Clip Securing

•  Remove the Trident body from wall clip.

•  Secure wall clip to a surface with a #6 mounting 

screw. 

•  Example securing locations: wall, baseboard or 

Optional Wall Clip Securing

•  Remove the Trident body from wall clip.

•  Secure wall clip to a wall with a #6 screw. 

•  Example securing locations are a wall, baseboard 

or cupboard.

Detects 

water pooled under the sensor and reports extreme air 

temperature conditions.

Default Temperature Trip Points

•  Heat alarms when over 100.4° F (38° C)

•  Heat restores when under 96.8° F (36° C)

•  Freeze alarms when under 44.6° F (7° C)

•  Freeze restores when over 48.2° F (9° C)

To replace the battery,

 insert a flat blade screwdriver into the 

front slot and twist. To reinstall the cover, align the rear latches 

and roll the cover forward until it snaps into place.

IN

STALL

G

U I D E

I

Mounting Screw Hole

Front slot

Wall Clip

Verify proper enrollment and operation using your control panel’s installation manual

.