background image

“GE”, “INTERLOGIX”, “HONEYWELL”, “DSC”, “2GIG”, AND “QOLSYS” ARE TRADEMARKS OWNED BY 

GENERAL ELECTRIC COMPANY, UNITED TECHNOLOGIES ELECTRONIC CONTROLS INC., 

HONEYWELL INTERNATIONAL INC., TYCO SAFETY PRODUCTS CANADA LTD, NORTEK SECURITY & 

CONTROL LLC, AND TYCO SAFETY PRODUCTS CANADA LTD, RESPECTIVELY.  

RESOLUTION PRODUCTS, INC. PRODUCTS WILL FUNCTION WITH ONE OF EITHER INTERLOGIX (FOR-

MERLY GE), HONEYWELL, DSC, 2GIG OR QOLSYS SYSTEMS.  HOWEVER, NO RESOLUTION PRODUCT IS 

PRODUCED BY, ENDORSED BY, NOR IS OFFICIALLY ASSOCIATED WITH INTERLOGIX (FORMERLY GE), 

HONEYWELL, DSC, 2GIG OR QOLSYS. RESOLUTION RECOMMENDS VERIFYING PROPER ENROLLMENT 

AND OPERATION, PER CONTROL PANEL INSTALLATION INSTRUCTIONS, AT INSTALLATION.

WARRANTY

RESOLUTION PRODUCTS, INC. WILL REPLACE PRODUCTS THAT ARE DEFECTIVE IN THEIR FIRST FIVE 

(5) YEARS.

FCC NOTICE

THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES.  OPERATION IS SUBJECT TO THE 

FOLLOWING TWO CONDITIONS:

(1)  THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE.

(2)  THIS DEVICE MUST ACCEPT ANY INTERFERENCE THAT MAY BE RECEIVED,  INCLUDING 

INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

CHANGES OR MODIFICATIONS NOT EXPRESSLY APPROVED BY RESOLUTION PRODUCTS, INC. COULD 

VOID THE USER’S AUTHORITY TO OPERATE THIS EQUIPMENT.

FCC ID: U5X-RE508X

IC NOTICE

THIS DEVICE COMPLIES WITH INDUSTRY CANADA LICENSE-EXEMPT RSS STANDARD(S). 

OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS:

(1)  THIS DEVICE MAY NOT CAUSE INTERFERENCE, AND

(2)  THIS DEVICE MUST ACCEPT ANY INTERFERENCE, INCLUDING INTERFERENCE THAT MAY

CAUSE UNDESIRED OPERATION OF THE DEVICE.

LE PRÉSENT APPAREIL EST CONFORME AUX CNR D’INDUSTRIE CANADA APPLICABLES AUX APPAREILS 

RADIO EXEMPTS DE LICENCE. L’EXPLOITATION EST AUTORISÉE AUX DEUX CONDITIONS SUIVANTES :

(1)  L’APPAREIL NE DOIT PAS PRODUIRE DE BROUILLAGE, ET

(2)  L’UTILISATEUR DE L’APPAREIL DOIT ACCEPTER TOUT BROUILLAGE RADIOÉLECTRIQUE SUBI,

MÊME SI LE BROUILLAGE EST SUSCEPTIBLE D’EN COMPROMETTRE LE FONCTIONNEMENT.

 
IC: 8310A-RE508X 

Notices

Manual: 47-0013-00 REV X6

Date: 04-Feb-16

24-Hour Tech Support Line: (877)260-5578

www.ResolutionProducts.com

Specifications

Specifications subject to change without notice.

This product is NOT for use with life safety devices, such 

as Smoke, Heat, or CO detectors.

PHYSICAL

Housing Dimensions

Weight with Battery

Tamper Activation

Mounting Screws

8.5 x 5.0 x 1.2 inches

10.4 Ounces

Cover Opening

#4 of #6

ENVIRONMENTAL

Operating Temperature

Storage Temperature

Maximum Humidity

32 to 120˚F (0 to 49˚C)

-4 to 86˚F (-20 to 30˚C)

85% relative humidity, non-condensing

POWER 

12VDC Output

Power Transformer

Input

Output

Part Number

Battery

Specifications

Part Number

Trickle Charge

Fast Charge

10.2VDC to 13VDC, 150mA Max 

(80m

A Max for UL installations)

100-240VAC 50/60Hz 0.5A

12VDC 1A

RE012-6

6VDC 800mAh NiMH

34-0012-00

8mA

32mA

WIRELESS RADIO

RF Frequency
Compatibility

319.5MHz, 345MHz, 433.92MHz

Cryptix

®

, Interlogix

®

 (formerly GE

®

),

Honeywell

®

, DSC

®

, 2GIG

®

, Qolsys

®

ZONES

Supported Types

Powered Zones

Non-Powered Zones

Battery Backup

Powered Zones

Non-Powered Zones

Zone End of Line Resistor

NC - No Tamper Detect

NC - Tamper Detect

NO - No Tamper Detect

NO - Tamper Detect

Zone Wire Length

Zone Wire Gauge

4-wire devices only

NC

 (Normal closed)

  or NO 

(Normal open)

4 hours minimum at 80mA

24 hours minimum

None (short)

750 ohm to 15k ohm

None (open)

750 ohm to 15k ohm
1000 feet max

22 AWG min

CERTIFICATIONS

ETL Listings

Other

UL 1023, ORD-C1023-1974

FCC, IC

Reviews: