RE208_Hardwire_to_Honeywell-Compat_Translator
Page
1
of
4
24-Hour Tech Support Line: (715)808-0164
30-Oct-14
www.ResolutionProducts.com
RE208 Hardwire-to-Honeywell
®
or 2GIG
®
Wireless Translator™
Features
•
Converts hardwire zones into Honeywell-compatible wireless signals.
•
8 Hardwire loops with end-of-line resistor detection.
•
Unique wireless ID for each zone, plus 1 for main device.
•
Transmit diversity for long reliable range.
•
PIR powering (via external supply).
•
3 year operation on batteries (contacts only).
•
Complete supervision of zone tampers and low battery.
Key Instructions
•
DO NOT MOUNT IN A METAL CAN.
•
DO NOT PUT POWER ON HARDWIRE TERMINALS.
•
Use with normally closed contacts in-line with 4.7 K-ohms resistors (mandatory).
•
Not for use with life safety devices, such as Smoke or CO sensors.
•
External supply requirements:
Contacts-only installations may use wall plug power supply (see specifications)
Installations with PIRs or Glassbreaks (powered devices) require battery-backed
external power supply (see diagram).
Without backed-up power, PIRs or Glass Breaks could alarm when
power is lost.
Translator AA batteries drive contacts only, and do not drive powered
devices.
Ensure that external supply has sufficient current to supply all
powered devices including Translator.
4-wire powered devices only. Not for use with 2-wire powered
devices.
If using old panel as the battery-backed 12V DC supply, verify supply
and battery operation. DO NOT MOUNT IN OLD CAN… the wireless will
not get out!
Installation
•
Hook up PIR and Glass Break power lines to external power supply.
•
Alarm contact hook-up:
Works only with normally-closed contacts (alarm = open).
Remove any existing end-of-line resistors.
Connect 4.7K end-of-line resistor (included) IN-LINE with contact
.
Resistor should NOT be across (between) terminals
.
Honeywell® Enrollment
Sensors:
RF Learning tripping enrollment mode.
Set up for any behavior desired.
Input Type: 3 (Supervised RF)
When prompted, open/close each zone
twice to enroll serial number.
Ensure it is set to Loop: 2.
Translator itself:
RF Learning tripping enrollment mode.
Zone Type: 8 (24 hour Aux)
Input Type: 3 (Supervised RF),
When prompted, toggle the tamper
switch to enroll serial number.
Loop 2 (but Loop doesn’t really
matter).
2GIG® Enrollment:
Sensors:
Q1 RF Sensor
Set up for any behavior desired.
At “Enter RF Serial Number”, press SHIFT LEARN, and trip sensor.
Ensure it is set to Loop 2.
Translator itself:
Sensor Type: (08) 24 Hour Aux
Equipment Type: (1) contact
Equipment Code: (0000) other
Other Equipment Code: (208) meaning RE208
Enter RF Serial Number: [press SHIFT,Learn, then toggle the tamper
switch to enroll the serial number]
Equipment Age: (0) new
Loop Number: (2) but Loop doesn’t really matter
Dialer Delay: (1) enabled
RE208_Hardwire_to_Honeywell-Compat_Translator
Page
2
of
4
24-Hour Tech Support Line: (715)808-0164
30-Oct-14
www.ResolutionProducts.com
•
Application Diagram
•
Connection Diagram
4.7K
Contact
(Normally Closed)
Loop
x
PIR
To Enroll zone,
Open and close contact.
This sends a open/close
signal to panel.
Translator AA
Batteries DO NOT
power external
devices
Altronix AL100UL
12VDC Supply
With Lead-acid
battery
Old Panel may be used,
if operation fully verified
+12 VDC GND
PIR
Power
Input
PIR Contact
Output
(Normally
Closed)
4.7K
Loop
y
Altronix TP1620
16.5VAC, 20VA
Transformer
with securing screw
Resolution
RE012
12 VDC
Power Supply
NON-Switched
Outlet
Use Battery-Backed 12VDC
if powering
PIRs or Glass Breaks
Use Non-Battery-Backed
Supply ONLY if installation is
all non-powered contacts
Power Supply polarity
DOES NOT matter!
End of Line
Resistor
New Wireless
System
Existing Hardwire Sensors
New Honeywell
Self-Contained System in
living area
Taking over old Hardwire panel,
usually mounted in utility area
Honeywell Wireless
May use GE 60-898-ITI supply here,
if securing screw is desired