Trident
is an integrated environmental sensor. It detects flood
conditions and reports extreme temperatures.
Features
• Titanium probes for unmatched corrosion immunity
• IP67 rated waterproof enclosure
• GORE
®
vent to prevent seal failure
• 5 year warranty
Enroll
by placing the panel into wireless enrollment mode and
removing the battery tabs, tampering the sensor, or manually
entering the sensor ID.
NOTE, Trident requires firmware
version 1.14 or later for GC2 Panel and 3.1 or later for
CG3.
For older panel firmware versions, use the RE218
Honeywell
®
Compatible Trident.
Panel Questions
Flood
Heat
Freeze
Sensor Type
[08] 24 Hour
Aux. Alarm
[08] 24 Hour
Aux. Alarm
[08] 24 Hour
Aux. Alarm
Equipment Type
[8] Water
[10] Temp.
[6] Freeze
Equipment Code
[1065] 2GIG
Flood Sensor
[1065] 2GIG
Flood Sensor
[1065] 2GIG
Flood Sensor
Sensor Age
[0] New
[0] New
[0] New
Loop Number
[1] Flood
[2] Heat
[3] Freeze
Install
by placing the sensor in the location requiring flood or
temperature detection. If desired, the wall clip can be used
to secure the Trident sensor.
Optional Screw Mounting
• Remove the wall clip from the Trident body.
• Secure the clip to a wall, baseboard or cupboard
using a #6 screw.
• Slide the Trident body down onto the wall clip until
it snaps into place.
Trident detects
water pooled under the sensor and reports
extreme temperature conditions.
Temperature Trip Points
•
Heat alarms when over 100°F (38°C)
•
Heat restores when under 97°F (36°C)
•
Freeze alarms when under 45°F (7°C)
•
Freeze restores when over 48°F (9°C)
To replace the batteries,
insert a flat blade screwdriver into
the front slot and twist. Slide both old batteries out and the
new batteries in. To reinstall the cover, align the rear latches
and roll the cover forward until it snaps into place.
I
N
STALL
G
U I D E
I
Verify proper enrollment and operation using your control panel’s installation manual
.
RE218T 2GIG
®
Compatible Trident
™
Environmental Sensor
Front slot
Mounting Screw Hole
Wall Clip