RE920 IP Module
Features
•
Connects in daughterboard slot of SimonXT panel
•
Allows reporting of alarm and status conditions over IP connection
•
Allows control of system functions (arming, disarming, etc) over IP
connection
•
Allows control of Zwave devices and wireless siren over IP connection
Key Instructions
•
Install RE920 unit in slot at back of panel
•
Power up the panel
•
Connect ethernet cable
•
Connect to configuration software and enter MAC address
•
Configure RE920 to correct IP address for reporting
•
Configure RE920 to correct IP address for system control
LED Operation
•
"L and S" LEDs are normal ethernet LEDs and indicate healthy ethernet
network connection
•
"Power" LED lights green when powered and shows heartbeat for
processor functioning correctly
•
"Local" LED lights when proper connection to local router established
•
"CS" LED lights when connected to Central Station
•
"Platform" LED lights when connected to interactive platform website