DeltaSol
®
BS Pro
© RESOL 06250 deltasol_bs_pr
o.monen.ind
d
7
|
S1
S2
S3
R1
R2
1.2.5 Allocation of clamps for system 5
1.2.6 Allocation of clamps for system 6
2-store-solar system with valve logic with 2 stores, 3
sensors, 1 solar pump and 1 3-way-valve. The sensor S4 /
TRF can optionally be used for heat quantity balancing.
R2
S4 / TRF
S1
R1
S2
S3
2-store-solar system with pump logic with 2 stores, 3
sensors and 2 solar pumps.
Arr 5
Arr 6
store 1
store 2
Store 1
Store 2
S4
Symbol
Specification
S1
collector sensor
S2
store sensor 1
S3
store sensor 2
S4 / TRF
sensor for heat quantity
balancing (optionally)
R1
solar pump
R2
3-way-valve
Symbol
Specification
S1
collector sensor
S2
store sensor 1
S3
store sensor 2
S4
measuring sensor
(optionally)
R1
solar pump
R2
solar pump