background image

SD card

An SD card has been supplied 

to gather therapy data from 

your Auto 25 device and provide 

settings updates from your 

clinician. When instructed to 

do so, disconnect the Auto 25 

device from the power outlet, 

remove your SD card, insert 

it in the protective folder and 

send it to your clinician.

Removing the card

1.

Push in the SD card to

release it.

2.

Remove the card.

3.

Insert the card into the

protective folder.

4.

Send the protective folder

back to your clinician as

instructed.

For more information on 

removing and inserting your 

card refer to the S9 SD Card 

Protective Folder provided with 

your device. Please retain the 

S9 SD Card Protective Folder 

for future use.

Notes:

 

For Troubleshooting information 

refer to the Information Guide.

 

For more product information

see www.resmed.com.

1.

2.

3.

4.

10

Summary of Contents for S9 Auto 25

Page 1: ... NSW 2153 Australia Distributed by ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA ResMed UK Ltd 96 Milton Park Abingdon Oxfordshire OX14 4RY UK See www resmed com for other ResMed locations worldwide For patent information see www resmed com ip S9 H5i ClimateLine SlimLine and SmartStart are trademarks of ResMed Ltd and S9 ClimateLine and SmartStart are registered in U S Patent a...

Page 2: ......

Page 3: ...r Standard air tubing SlimLine air tubing 3m air tubing ClimateLine heated air tubing ClimateLineMAX heated air tubing 30W power supply unit does not support H5i Power Station II battery pack DC DC Converter 24V 90W Welcome Thank you for choosing the Auto 25 Before operating this device please read the entire Welcome and Information Guides Air filter DC power inlet SD card slot Module Adapter port...

Page 4: ...r end of the power cord into the power outlet 4 Connect one end of the air tubing firmly onto the air outlet 5 Connect the assembled mask system to the free end of the air tubing Notes For more information on assembling your mask see your mask user guide Recommended masks are available on www resmed com on the Products page under Service Support 2 ...

Page 5: ...view your sleep statistics or exit from the menu Push dial Turning the dial allows you to scroll through the menu and change settings Pushing the dial allows you to enter into a menu and confirm your choice LCD screen Displays the menus treatment screens and reminders Start Stop button Starts or stops treatment The Info and Setup menus are disabled if S9 Essentials has been enabled by your clinici...

Page 6: ...just your mask fit to minimise leaks 1 Fit your mask as described in the mask user guide 2 From your home screen push and hold for three seconds One of the following MASK FIT screens is displayed 3 If necessary adjust your mask mask cushion and headgear until you have a Good mask fit After three minutes the pressure reverts to the set pressure and treatment will begin You can end mask fit at any t...

Page 7: ... humidification and Climate Control Selecting the mask type To select your type of mask 1 Press The SETTINGS screen is displayed 2 Turn until Mask is displayed in blue 3 Press The selection is highlighted in orange Note Selecting the mask type is not possible if S9 Essentials has been enabled by your clinician 4 Turn until the mask setting that you require is displayed 5 Press to confirm your choi...

Page 8: ...and arrange the air tubing so that it is free to move if you turn in your sleep 6 To stop treatment at any time remove your mask and or press Notes If your clinician has enabled SmartStart your device will start automatically when you breathe into the mask and stop automatically when you remove the mask If power is interrupted during treatment the device automatically restarts therapy when power i...

Page 9: ... 9 ClimateLine or ClimateLineMAX heated air tube 9 9 Climate Control Manual 9 9 Standard Auto 25 without optional accessories 9 9 Oximetry data via the oximeter adapter In VAuto mode the fixed lines on the pressure bar indicate the expiratory and inspiratory pressures In CPAP mode only a set pressure is shown While the treatment is ramping indicated by an orange ramp icon below the pressure bar th...

Page 10: ...rmation To view the Info menu push from your HOME screen 9 9 In the Sleep Quality screen you can always view your usage hours during the last session and if enabled by your clinician data on mask fit and AHI is displayed 9 9 In the Sleep Report only the period can be changed other values are for display only 9 9 In the Service information the device run hours includes warm up cool down times for t...

Page 11: ...llow to dry 4 Before next use reconnect the air tubing to the air outlet and mask Monthly 1 Wipe the exterior of the Auto 25 device with a damp cloth and mild detergent 2 Check the air filter for holes and blockage by dirt or dust Replace the air filter if necessary Replacing the air filter Replace the air filter every six months or more often if necessary 1 Remove the air filter cover from the ba...

Page 12: ...Removing the card 1 Push in the SD card to release it 2 Remove the card 3 Insert the card into the protective folder 4 Send the protective folder back to your clinician as instructed For more information on removing and inserting your card refer to the S9 SD Card Protective Folder provided with your device Please retain the S9 SD Card Protective Folder for future use Notes For Troubleshooting info...

Page 13: ......

Page 14: ...zabeth Macarthur Drive Bella Vista NSW 2153 Australia Distributed by ResMed Corp 9001 Spectrum Center Boulevard San Diego CA 92123 USA ResMed UK Ltd 96 Milton Park Abingdon Oxfordshire OX14 4RY UK See www resmed com for other ResMed locations worldwide For patent information see www resmed com ip S9 H5i ClimateLine SlimLine and SmartStart are trademarks of ResMed Ltd and S9 ClimateLine and SmartSt...

Reviews: