Setting Up Your ResMed Connectivity Module (RCM)™ 

with the Stellar150™ 

 

Important Points: 

 

 

The RCM™ can only be connected to one device at a time. It is best used with your 

main device that you use most often if you have more than one device. 

 

The RCM™ is ideally placed 12” away from your Stellar150™ or other electrical 

equipment and 1m (3’3”) away from mobile communication devices such as a cell 

phone. 

 

Make sure the RCM™ is placed more than 2cm (0.8”) away from your body during 

operation. 

 

 

 

 

 

 

 

Operating State 

Power - Green:  ON:  power is connected and on 
                          OFF: power is off 

Vent. Input - Blue:  ON:  connected to the Stellar150™ 

                                   OFF: disconnected 

                                  BLINKING: connecting to Stellar150™  

 

Note:  The Blue Vent. Input led will be OFF when the 

Stellar150™ device is off but will come back on when the 

Stellar150™ unit is turned back on to start therapy 

                     
Signal – Blue: ON:  indicates connectivity to the cellular 

                                 network and signal strength 

                         OFF: no cellular network detected 

 

Note:  The RCM™ needs to detect a cellular network in 

order to transmit daily data.  Contact the VEP if your 

device is not detecting a network in your area. 

 
 
 
                                 
 
 
 
    

Error Indicator:  If ON, unplug and plug the RCM™ back in.  

If this does not remove the error call the VEP for 

assistance in troubleshooting or replacement if needed 

Summary of Contents for RCM

Page 1: ...e a day from home wirelessly and automatically to assist in the remote display of data from your Stellar150 The RCM is intended to be used in the home environment for the collection and transmission of respiratory and device data to AirView The RCM will not control your Stellar150 device but will help your clinical team guide your care by downloading important therapy and device data to AirView A ...

Page 2: ...d 2 ResMed Connectivity Module RCM Quick Set up Guide To begin the installation of the RCM unpack the parts needed for the set up as shown Have your Stellar150 device plugged in and powered ON The ResMed Connectivity Module RCM USB cable Power Supply Unit PSU ...

Page 3: ...wer cord extends downward Locate the power inlet port on the back of the RCM Plug other end of the power cord into the RCM to power it on Connect the gray end of the USB cable to the USB port located on the back of the RCM Insert the USB connection on the other end of the USB cable to the back of your Stellar 150 device The port can be found on the back of your device next to the power cable and i...

Page 4: ... State Power Green ON power is connected and on OFF power is off Vent Input Blue ON connected to the Stellar150 OFF disconnected BLINKING connecting to Stellar150 Note The Blue Vent Input led will be OFF when the Stellar150 device is off but will come back on when the Stellar150 unit is turned back on to start therapy Signal Blue ON indicates connectivity to the cellular network and signal strengt...

Page 5: ...n find the Device Number on this page In this case the device number for this Stellar150 is 110 To exit from this screen and return to therapy push the Monitor button Each Stellar150 will have its own unique Device Number Your device will have a different number This number will allow us to identify your equipment to allow us to connect your device to the ResMed AirView program Where multiple Stel...

Reviews: