EN1R

9099 2004R8

NE 

 

 

 

 

V4600/V8600E,T 

COMPACT GAS CONTROL WITH THROTTLE VALVE 

 

  

INSTRUCTION SHEET 

Dimensions 

See fig. 1. 

Ambient temperature 

0 ... 70 °C 

Pipe connection 

Pipe connections are designed to meet the bending stress of 

group 2 according to EN 161. 

Standard: 

Inlet: 

1

/

2

” ISO 7

1 internal parallel pipe thread. 

Outlet:  

1

/

2

” ISO 7

1 internal parallel pipe thread or 

Ø18.6 mm without thread. 

Inlet and outlet can also be made with straight or elbow 

flanges. 

Special connection: Side outlet Ø14 mm

 

 
APPLICATION 

V4600/V8600E,T gas controls, together with Resideo pilot 

burner/thermocouple and room/boiler thermostats, provide all 

the functions necessary to safely regulate gas flow pilot 

burner and main burner manifold of domestic heating boilers 

(free standing and wall mounted), warm air furnaces and back 

boilers. 
V4600/V8600E,T gas controls are intended to be used for 
manufactured, natural and LP gases (1

st

, 2

nd

, 3

rd 

family gas). 

V4600/V8600E,T gas controls are approved in accordance 

with existing european standards. 

DESCRIPTION 

V4600/V8600E,T gas controls comprise a pilotstat 

mechanism, throttle valve and an electric operated on/off 

valve. 
The pilotstat is a thermoelectric safety device according to 

european standards EN 125 and EN 126 and closes off the 

gas supply to both main burner and pilot burner. 
The electric on/off servo operator is an automatic shut

off 

valve of class J according to EN 161 and closes off the gas 

supply to the main burner. 

SPECIFICATIONS 

Models 

V4600 serie: 220/240 V, 50 Hz. 

V8600 serie: 24 V, 50 Hz. 

Suffix E: fast opening and throttle valve 

Suffix T: slow opening and throttle valve 

Pilot gas connection

 

Standard at end outlet: 

1

/

4

”, 4 mm or 6 mm outer diameter 

tubing. 

Special connection: Included in the side outlet. 

Capacity* 

In m

3

/

air at 

P of 2.5 mbar. 

Pipe connection 

Capacity 

1

/

2

” x 

1

/

2

” 

3.15 

1

/

2

” x Ø18.6 mm 

3.15 

1

/

2

” x Ø14 mm side outlet 

2.2 

Capacity curves are available on request. 

Minimum differential pressure 

Between inlet and outlet: 2.5 mbar 

Minimum adjustable capacity 

1.5 m

3

/

air at 

P of 20 mbar 

Maximum operating pressure 

The P

max 

indication on the housing of the gas control is the 

maximum inlet pressure at which the gas control functions 

safely. 

Mounting holes 

Two M5 mounting holes are located on the bottom of the gas 

control. 
The four holes at inlet and outlet for mounting the flange on 

the gas control are provided with M5 thread with minimum 

6.5 mm full thread. 

The four holes for mounting the flange to the side outlet are 

provided with M4 thread with min 6 mm full thread. 

 

Summary of Contents for V4600

Page 1: ...electric safety device according to european standards EN 125 and EN 126 and closes off the gas supply to both main burner and pilot burner The electric on off servo operator is an automatic shut off valve of class J according to EN 161 and closes off the gas supply to the main burner SPECIFICATIONS Models V4600 serie 220 240 V 50 Hz V8600 serie 24 V 50 Hz Suffix E fast opening and throttle valve ...

Page 2: ...uding cover IP 40 with cover or plug IP 44 with plug according to DIN 43650 INSTALLATION IMPORTANT Take care that installer is a trained experienced service person Turn off gas supply before starting installation Disconnect power supply to prevent electrical shock and or equipment damage Do not remove seals over gas control inlet and outlet until the device is ready to be installed Working voltage...

Page 3: ...With the main burner in operation paint all pipe joints including adapters and gas control inlet and outlet with with a rich soap and water solutionan approved leak detection fluid If another gas leak is detected tighten adapter screws joints and pipe connections Replace the part if gas leak can not be stopped CAUTION Keep soap and water solution away from electrical connections Electrical connect...

Page 4: ...0 Volt Pressure tap The gas control is provided with a pressure tap of 9 mm outer diameter at inlet and outlet side When checking the pressure undo the screw a half turn and slip tube over nipple Ensure that screw is retightened after making test Pilot flame adjustment see fig 1 The gas control is packed for shipment with pilot flow at maximum Refer to the pilot burner manufacturer s instructions ...

Reviews: