T6R-HW 

SMART THERMOSTAT 

T6R-HW-EN0H 8604 NL01 R1020 

 

 

INSTALLATION 

To ensure your safety, 

always make sure mains power is switched OFF 

before accessing wiring. 

Before 

removing 

the old thermostat 

take a picture of the old thermostat’s wiring as a reference then proceed to installation. 

 

The T6R thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2 - 1.5 

meters from the floor. 

Maximum cable length between Receiver box and thermostat: 

15m for 0.5mm² cable or 20m for 1.0mm² cable. 

 

 

Prepare 2-channel Receiver Box 

Needed during installation: 

 

Cable with 2 wires from the heating valve to Receiver Box. 

 

Cable with 2 wires from the hot water valve to Receiver box. 

 

The 2-channel Receiver Box requires 230V power 

Find a suitable location near the boiler. Leave at least 30cm distance from any 

metal objects including wall boxes and boiler housing. 
Loosen the front screw to remove cover or tighten it when the cover is back in 

position. 

 

Install 2-channel Receiver Box 

A.

 

Wall box or Rear wiring 

Hinge open the terminal block flap to access 

the cables and wall box screw holes. 

 

B.

 

Surface wiring 

Use the cable clamps to secure the 

surface wiring. 

 

Replace cover 

Locate the hinges at the top of the 

cover and wall plate, close the 

cover and secure with the screw. 

 

 

 

 

Note: See the wiring diagrams on page 9 for the correct wiring connections. 

Summary of Contents for Honeywell Home T6R-HW

Page 1: ...for Sundial S Y and W plan stored hot water systems on off Not with electric heating 240V The T6R HW is for table stand installations wireless and consist of a thermostat and a Receiver box The soluti...

Page 2: ...10 T6R HW EN0H 8604 NL01 R1020 T6R HW SMART THERMOSTAT Schedule period THERMOSTAT DISPLAY BUTTON LAYOUT Reference to the icons 2 CHANNEL RECEIVER BOX...

Page 3: ...60 Hz 0 5 A to 5 A resistive 0 5 A to 3 A inductive 0 6 pf Cycle rate Selectable by application see installer set up Wiring Terminal block capable of accepting wires up to 1 5 mm2 Wire access From bac...

Page 4: ...etting What do you need to change Cycle Hour Minimum ON time in minutes Note a To change Cycle Hour b To change Minimum ONTime Heating Gas Boilers 30KW 6 1 No action required Oil Boiler 3 4 1 Set Mini...

Page 5: ...aters and heat recovery units and room thermostats Via the OpenTherm protocol the Receiver box of the T6 T6R thermostat constantly communicates with the connected appliance Modulating The T6 T6R therm...

Page 6: ...ture Return Water Temperature Actual return water temperature Max Supply Water Temperature Hot water Temperature Actual hot watertemperature Hot Water Setpoint Actual Power Actual power of appliance W...

Page 7: ...tion Cable with 2 wires from the heating valve to Receiver Box Cable with 2 wires from the hot water valve to Receiver box The 2 channel Receiver Box requires 230V power Find a suitable location near...

Page 8: ...lation Turn ON mains power to the Heating Appliance and 2 channel Receiver Box Setup and configuration After power up SETUP is displayed on the thermostat s screen Touch to begin Select language Set c...

Page 9: ...a moment 3 Put the Receiver box into binding mode by pressing the Heat button for 3 sec The first LED will flash amber 4 Enable binding on thethermostat Enter the advanced menu by pressing the button...

Page 10: ...T6R HW SMART THERMOSTAT 10 T6R HW EN0H 8604 NL01 R1020 WIRING...

Page 11: ...RF SIGNAL OFRECEIVER BOX LOW There is a weak radio signal from the Receiver box Try to move thermostat or Receiver box closer or re locate NO RECEIVER BOX The thermostat is not bound with the Receiver...

Reviews: