INSTALLATION
To ensure your safety,
always make sure mains power is switched OFF
before accessing wiring.
Before
removing
the old thermostat
take a picture of the old thermostat’s wiring as a reference then proceed to installation.
The T6R thermostat should not be placed near draughts, in direct sunlight or near heat sources. It should be at least 1.2 - 1.5
meters from the floor.
Maximum cable length between Receiver box and thermostat:
15m for 0.5mm² cable or 20m for 1.0mm² cable.
Prepare 2-channel Receiver Box
Needed during installation:
•
Cable with 2 wires from the heating valve to Receiver Box.
•
Cable with 2 wires from the hot water valve to Receiver box.
•
The 2-channel Receiver Box requires 230V power
Find a suitable location near the boiler. Leave at least 30cm distance from any
metal objects including wall boxes and boiler housing.
Loosen the front screw to remove cover or tighten it when the cover is back in
position.
Install 2-channel Receiver Box
A.
Wall box or Rear wiring
Hinge open the terminal block flap to access
the cables and wall box screw holes.
B.
Surface wiring
Use the cable clamps to secure the
surface wiring.
Replace cover
Locate the hinges at the top of the
cover and wall plate, close the
cover and secure with the screw.
Note: See the wiring diagrams on page 9 for the correct wiring connections.