LOCATION GUIDELINES
The FG-1625R/RT detects framed glass broken by an impact sufficient to make a hole.
Refer to the following guidelines when selecting a mounting location:
•
The FG-1625R/RT can be mounted in corners, on walls, and on ceilings.
•
Mount within 25’ (7.6 m) of the glass.
•
There is no minimum range, but the detector must have a clear line-of-sight and a
clear view of the glass.
•
The ideal location is on the wall or ceiling directly opposite the glass. The least
desirable location is on the same wall as the glass.
•
When wall mounting, mount the detector a minimum of 6’ (1.8 m) high.
•
Curtains, blinds and other window coverings absorb energy from breaking glass.
Heavy curtains, for example, effectively block the sound signal. In these cases,
mount the detector on the window frame behind the window covering or above the
window.
•
Do not mount within 3’ (0.9 m) of forced air ducts, sirens, or bells measuring 2” (5
cm) or more in diameter.
•
Minimize range to the glass. Do not install beyond the maximum specified range
even if testing indicates greater range.
•
Adjust sensitivity for desired range; verify by testing with the FG-701.
•
Mounting on freestanding posts and pillars is not recommended.
•
Verify all installations back to the panel to be sure the protection loop is intact.
•
Do not use outside.
•
Avoid installing in rooms with high-level noise sources, such as air compressors,
bells, and power tools if those sources can be active when the detector can
signal an alarm.
•
Test false alarm immunity by activating any noise sources in the room.
Note:
The FG-1625R/RT detects shattering of framed glass by a direct impact. It may
not consistently detect breakage by blows that only crack the glass, by high velocity
projectiles (such as bullets) or if the glass is broken without an impact.
USING THE CEILING/WALL TAMPER SWITCH (FG-1625RT ONLY)
The FG-1625RT has a combination normally-closed (NC) cover and wall tamper.
Each detector is shipped with the cover tamper operational and the ceiling/wall
tamper disabled.
•
Use needle-nose pliers to break out the plastic tab on the back of the detector. The
tamper arm then extends through the hole.
•
The tamper screw (not provided) should be a flat-head #8 (4.2 mm) or Tamper
#10 (4.8 mm) screw.
•
Install the tamper screw so it will just make
contact with the bottom of the mounted
detector’s tamper cavity.
•
After installing the tamper screw, position the
detector over it and mark
the locations for the mounting screws.
LED INDICATORS
The two LEDs on the front cover indicate the detector's operational status. The
following table summarizes the LED operation when the LEDs are enabled.
Protected glass:
Minimum size for all types is 11 inches (28 cm) square. Glass must be framed in the wall of the
room or mounted in a barrier of 36 inches (0.9 m) minimum width.
1
Protected only if both glass plates are broken.
2
Coated glass with security films up to 0.35mm (14 mils) thick (including films for solar
protection) may be used. Evaluated with these products: 3M
®
SCOTCHSHIELD
®
SH14CLARL – 0.35mm
(14 mils), 4 ply film; Film Technologies International, Inc.’s GLASS-GARD
®
GGLL 1200 –
0.3mm
(12 mils), 3 ply film by Underwriters Laboratories, Inc., at Resideo’s request.
3
In compliance with Underwriters Laboratories of Canada’s Standard for Intrusion
Detection Units (CAN/ULC-S306-M89)
a
ULC recognizes a maximum range of 6m (20 ft.) for protecting 2mm (3/32”) plate and and
3mm (1/8”) laminated.
b
ULC recognizes a maximum range for protecting 3mm (1/8”) sealed insulating glass and
all coated glass of 4m (12.5 ft.).
4
UL recognizes a maximum range for protecting 3mm (1/8”) sealed insulating glass of 6m (20
ft.) with sensitivity set at maximum.
IMPORTANT:
The FG-1625R/RT must be connected to a UL listed power
supply or UL listed control unit capable of providing
a minimum of four hours
of standby power.
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
2020 Resideo Technologies, Inc.
www.resideo.com
SPECIFICATIONS
Range:
Operating temperature:
25 feet (7.6 m) maximum
14° F to 131°F (-10° C to 55°C)
No minimum range
UL: 14° F to 122°F (-10° C to 50°C)
Alarm relay:
(Indoor use environment)
FG-1625R Form A
Storage: -4° F to 131° F (-20° C to 55° C)
FG-1625RT Form C
-4° F to 122° F (-20° C to 50° C)
100 mA maximum
ESD immunity:
25 VDC maximum
10 kV, Discharges of either polarity to exposed
ON/closed 22
ʌ
±6
ʌ
surfaces
OFF/open >1M
ʌ
Dimensions:
Alarm duration:
4.25” OD x 0.88” THK 5
seconds (unaffected by alarm LED
(108 mm x 22.4 mm)
latching)
Weight:
Tamper switch: (FG-1625RT only)
4.5 oz., (128 g)
Combination cover and wall tamper
Packaged product: 7.5 oz., (213 g) 25
mA maximum
Accessories:
24 VDC maximum
FG-701 Glassbreak Simulator
Power requirements:
FG-SP2 Spacer Plate
8 - 16 VDC; 12 mA typical at
Approvals/Listings:
12 VDC, 22 mA max.;
FCC and IC Verified
AC Ripple: 4 Volts peak-to-peak
UL Listed
at nominal 12 VDC
ULC Listed
RFI immunity:
CE
30 V/m, 10 MHz - 1000 MHz
FG-1625RT only:
ESD immunity:
EN 50131-1, Grade 2, Class II
10 kV, Discharges of either polarity to
Suitable for connection to an EN 60950 Class II
exposed surfaces
Limited Power Source
Responsible Party / Issuer of Supplier’s Declaration of Conformity: Ademco Inc., a subsidiary
of Resideo Technologies, Inc., 2 Corporate Center Drive., Melville, NY 11747, Ph: 516-577-
2000
For any additional information regarding the compliance of this product to any EU specific requirements,
please contact:
Sécurité Communication
1198, Avenue du Docteur Maurice Donat
BP 1219 - 06254 MOUGINS CEDEX, FRANCE
Tel.: +33 (0)4 92 94 29 50
fax: +33 (0)4 92 94 29 60.
NOTICES
FCC NOTICE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures: 1) Reorient or relocate the receiving
antenna, 2) Increase the separation between the equipment and receiver, 3) Connect the
equipment into an outlet on a circuit different from that to which the receiver is connected,
4) Consult the dealer or an experienced radio/television technician for help.
The user is cautioned that changes or modifications not expressly approved by Resideo
could void the user’s authority to operate this equipment.
IC Notice:
This Class B digital device apparatus complies with the Canadian standard
ICES-003. Cet appareil numérique de la Classe B est conforme à la norme NMB-003
du Canada.
Ê5-051-738-00F*Š
This product is manufactured by Resideo and its affiliates.
For the latest U.S. warranty information, please go to: www.resideo.com or Please contact your local
authorized Resideo representative for product warranty information.
5-051-738-0
0F 7/14 Rev. F
Condition
Green LED
Red LED
Normal
OFF
OFF
Normal, event detected
Flicker
OFF
Normal, break detected
OFF
ON 5 seconds
Normal, alarm latched
OFF
ON continuously
Power up
ON 1 second
ON 1 second
Low voltage
Flash ON/OFF
Flash ON/OFF
Test Mode
Flash once per second
OFF
Test Mode, event detected
Flicker
OFF
Test Mode, alarm
Flash once per second
ON 5 seconds
Type
Thickness
Minimum
Maximum
Plate
3a,4
3/32” (2 mm)
3/8” (10 mm)
Tempered
1/8” (3 mm)
3/8” (10 mm)
Laminated
1,3a
1/8” (3 mm)
9/16” (14 mm)
Wired
3a
1/4” (6 mm)
1/4” (6 mm)
Coated
2,3b
1/8” (3 mm)
1/4” (6 mm)
Sealed Insulating
1,3b,4
1/8” (3 mm)
1/4” (6 mm)
[1/2” (13 mm overall)]
[3/4” (19 mm overall)]