RePower NIUESS User Manual Download Page 1

深圳市瑞能时代科技有限公司

RePower Technology Co., Ltd

Energy Storage System

User manual

Summary of Contents for NIUESS

Page 1: ...RePower Technology Co Ltd Energy Storage System User manual...

Page 2: ...tallation operation and maintenance to ensure correct use and high performance of operation on the machine The use of the energy storage system must comply with local laws and regulations on grid tied...

Page 3: ...egrated machine 11 4 Installation 12 4 1 Unpacking confirmation 12 4 2 Preparation before installation 14 4 2 1 Installation tools 14 4 3 Electrical connection 16 4 3 1 Battery connection 17 4 3 2 PV...

Page 4: ...Energy storage integrated machine Content 5 3 2 Instruction for setup parameter 27 5 3 3 Inverter data display 29 6 Fault code 30...

Page 5: ...Statement Our company shall not be liable for any consequence caused by any of the following events Damage caused by transportation The storage conditions do not meet the requirements specified in th...

Page 6: ...is manual Sign Name Description Abbreviation Danger Danger Serious physical injury or even death may occur if related requirements are not followed Warning Warning Physical injury or damage to the dev...

Page 7: ...lectrical standards Do not touch the housing of the machine or the radiator to avoid scald as they may become hot during operation Ground with proper technical before operation Do not open the surface...

Page 8: ...rgy storage integrated machine Safety precautions 5 Single PV string cannot connect to muti inverters One battery bank cannot be connected to muti inverters Inverters do not support three phase operat...

Page 9: ...Energy storage integrated machine Safety precautions 6 Back up cannot connect in parallel On grid or back up side cannot connect any ac generator...

Page 10: ...se to flammable or explosive materials Do not install the machine in a place where children and ottier people can easily touch it lb avoid a risk of electric shock please remove rings bracelets and ot...

Page 11: ...rn non professionals to enter or use fence for isolation Before carrying out any maintenance operations all input power to the machine must be disconnected first and wait for at least 5 minutes until...

Page 12: ...hapter mainly describes the appearance packaging accessories and other information of energy storage integrated machines 2 1 Energy storage system Figure 2 1 Energy storage system Symbol Description A...

Page 13: ...egrated machine Product overview 7 2 2 Product appearance Figure 2 2 Appearance of RESS 5000 A of the all in one energy storage machine Figure 2 3 Appearance of inverter module of the all in one energ...

Page 14: ...COMM DRM COMM DRM communication port 3 Fan Cooling fan 4 PV connection terminal block PV DC input terminal of the inverter 5 RS485 3 RS485 3 communication port 6 RS485 1 2 RS485 1 2 communication port...

Page 15: ...e phase energy storage integrated machine 3kW 3000 Note Technical parameters of the energy storage integrated machine refers to appendix 2 4 Dimensions and weight Figure 2 4 Dimensions of the energy s...

Page 16: ...n and dry place and prevent the erosion of dust and water vapor The storage temperature should be kept at 20 C 60 C and the relative humidity should be kept at 4 RH 100 RH Keep away from chemically co...

Page 17: ...he idled machine in its original package and take anti moisture and anti dust measures After taking the machine out of the box check the following items Confirm the main body of the machine is intact...

Page 18: ...tity remarks A 3 kW 5 kW energy storage integrated machine cabinet 1 B communication connector 2 C RS485 communication connector 1 D DRMO communication connector 1 E RS485 Communication link 1 F RJ45...

Page 19: ...Energy storage integrated machine Installation 13 4 2 Preparation before installation 4 2 1 Installation tools...

Page 20: ...d machine Installation 14 Figure 4 2 Installation spacing unit IN In order to ensure good ventilation of the energy storage integrated machine please reserve enough installation spacing around the mac...

Page 21: ...ote Should not be installed in direct sunlight rain snow cover and other places 4 3 Electrical connection This section introduces the detailed contents and safety precautions related to electrical con...

Page 22: ...arried out by professional technicians as wrong operation may cause damage to the device physical injuries or even death during system operation All the electrical installation must conform to the nat...

Page 23: ...rgy storage integrated machine do not use other connection devices without authorization from our company otherwise damage to the device unstable operation or fire may occur and our company will not u...

Page 24: ...ation resistance of the PV panel to the ground should be greater than the safety regulation otherwise there will be electrical hazards Figure 4 4 PV wire stripping length and crimping PV and PV termin...

Page 25: ...must be taken in accordance with the local electrical safety regulations The PE cable grounding cable of the machine must be reliably grounded Connect the three wires L N and PE of the single phase pu...

Page 26: ...4 4 3 Definition of CAN interface pin in the battery Figure 4 7 CAN communication 1 2 3 4 5 6 7 8 GND CANH CANL 4 4 4 Definition of CAN2 interface pm in the energy storage inverter Figure 4 8 CAN2 co...

Page 27: ...our company s WIFI and GPRS communication It can realize local monitoring remote monitoring as well as mobile APP monitoring The RS 485 communication interface of our energy storage integrated machin...

Page 28: ...munication Pin definition 1 5VDC 2 A RS3485 3 B RS3485 4 GND Users can select RS 485 1 2 3 to communicate during RS 485 communication If selecting our company s WIFI and GPRS for monitoring users only...

Page 29: ...nergy storage integrated machine Pin definition 1 DRM1 5 2 DRM2 6 3 DRM3 7 4 CT 5 CT 6 BAT_NTC1 7 BAT_NTC2 8 DRM4 8 9 REF 10 NC 11 NC 12 COM Detail instructions 1 Pin1 Pin2 Pin3 Pin8 Pin9 Pin12 are us...

Page 30: ...Icon instruction Icon Instruction PV information displaying parameters related to PV panel such as PV voltage current power etc Inverter data display and parameter setting Grid information displaying...

Page 31: ...Energy storage integrated machine LCD operation instructions 24...

Page 32: ...on 8 Monthly generation 9 Annual generation 10 Total generation Energy storage integrated machine information 1 operation 2 Alarm 3 Power curve 4 Configuration Grid information 1 Grid voltage 2 Grid c...

Page 33: ...rent power 5 Daily consumption 6 Monthly consumption 7 Annual consumption 8 Total consumption 5 3 Parameter setup of the energy storage integrated machine 5 3 1 Parameter classification page The param...

Page 34: ...ry protocol 1 Pylon 2 Sunwoda 3 Yinlong 4 Xstellar 5 FES 6 Olipower 7 GCL 8 DLG 9 Penghui 10 Yiwei 3 Charge voltage Charge voltage Charge voltage range 0 60 V 4 Charge current Charge current Charge vo...

Page 35: ...ge time period 3 range 0 23 59 Charge time period 3 ends End time of charge time period 3 range 0 23 59 12 Discharge time period 3 setup Discharge time period 3 starts Start time of charge time period...

Page 36: ...ing mode Working mode of the inverter 2 Temperature Temperature in the inverter 3 Device type 4 Production data 5 Auxiliary DSP software version no 6 Product SN 7 Grid tied standard 8 Hardware version...

Page 37: ...ncy is higher than protection point 2 07 Ac freq Iow1 Grid frequency is lower than protection point 1 08 Ac freq Iow2 Grid frequency is lower than protection point 2 09 Ac over currhw Output hardware...

Page 38: ...volt high Battery overvoltage 40 Battery open Battery shut down 41 Quik stop E stop 42 Pv1 over current hw PV1 hardware overcurrent 43 Pv2 over current hw PV2 hardware overcurrent 44 Bat over current...