Terminology

 

Link Aggregation:  

It is a method to have multiple physical links with the same media and speed 

bundled to be a logical link forming a Link Aggregation Group with a group ID. With 
the viewpoint of MAC client, each Link Aggregation Group is an independent link.  

There are three cases of link used in the network, which are switch to switch, 

switch to station and station to station. Here station may be a host or a router. 

Link Aggregation, called port trunking sometimes, has two types of link 

configuration, including static port trunk and dynamic port trunk.  

 Static Port Trunk:  

When physical links are changed, administrator needs to manually 
configure the switches one by one. 

 Dynamic Port Trunk:  

When physical links are changed, LACP takes over and automatically 
reconfigure. Administrator does not have to do anything and may see the 
trap message of LACP changed in NMS.   

 
 

 

 
 

Fig. 3-10 Example of Link Aggregation Application 

 

Publication date:Nov., 2012 

 Revision A1

 

43

Summary of Contents for RP-PG081W

Page 1: ...User Manual Release 0 93 2012 Manufacture Corporation All rights reserved All brand and product names are trademarks or registered trademarks of their respective companies Publication date Nov 2012 R...

Page 2: ...bled software or firmware each of which is referred to as Software in this Agreement BY COPYING OR USING THE SOFTWARE YOU ACCEPT ALL OF THE PROVISIONS AND CONDITIONS OF THIS AGREEMENT THE PROVISIONS E...

Page 3: ...d to Manufacture s copyright in the Software and related documentation will cease being effective at the date of expiration Notwithstanding the termination or expiration of the term of this agreement...

Page 4: ...ATIONS 19 3 21 BASIC CONCEPT AND MANAGEMENT 3 1 WHAT S THE ETHERNET 21 3 2 LOGICAL LINK CONTROL LLC 22 3 3 MEDIA ACCESS CONTROL MAC 24 3 4 FLOW CONTROL 29 3 5 HOW DOES A SWITCH WORK 32 3 6 VIRTUAL LAN...

Page 5: ...ENANCE 87 4 4 1 Warm Restart 88 4 4 2 Factory Default 89 4 4 3 Software Upgrade 90 4 4 4 Configuration File Transfer 91 4 4 5 Logout 92 5 MAINTENANCE 93 5 1 RESOLVING NO LINK CONDITION 93 5 2 Q A 93 A...

Page 6: ...Publication date Nov 2012 Revision A1 vi Revision History Release Date Revision 0 90 Aug 07 2012 A1 0 93 Nov 19 2012 A2...

Page 7: ...e switch supports the SFP Vendor includes Manufacture Agilent Avago and Finisa Electronic Emission Notices Federal Communications Commission FCC Statement This equipment has been tested and found to c...

Page 8: ...ion on Product is strictly prohibited Damage caused by self demolition will be charged for repairing fees Do not place product at outdoor or sandstorm Before installation please make sure input power...

Page 9: ...ch This guide also covers management options and detailed explanation about hardware and software functions Overview of this user s manual Chapter 1 Introduction describes the features of 9 port Gigab...

Page 10: ...ll IEEE 802 3z and 1000Base SX LX standards 1000Mbps Single Fiber WDM BiDi transceiver is designed with an optic Wavelength Division Multiplexing WDM technology that transports bi directional full dup...

Page 11: ...rehensive features listed below for users to perform system network administration and efficiently and securely serve your network Hardware 8 10 100 1000Mbps Auto negotiation Gigabit Ethernet TP ports...

Page 12: ...9600 bytes for jumbo frame application Supports Broadcasting Suppression to avoid network suspended or crashed Supports to send the trap event while monitored events happened Supports default configur...

Page 13: ...e 8 TP Gigabit Ethernet PoE ports and 1 SFP fiber ports for optional removable modules on the front panel of the switch LED display area locating on the left side of the panel contains a Power LED whi...

Page 14: ...s speed Lit Yellow when TP link on 10 100Mbps speed Off when no link occur 1000SX LX Gigabit Fiber Port 9 LED LINK ACT Green Lit when SFP connection with remote device is good Blinks when any traffic...

Page 15: ...Fiber transceiver SFP LC S50 C SM 20km 1310nm SFP Fiber WDM transceiver SFP BS3 S20 C SM 20km 1550nm SFP Fiber WDM transceiver PS The other spec is available upon request iew of the Optional Modules I...

Page 16: ...ch is OFF before you insert the power cord to power source Installing Optional SFP Fiber Transceivers to the 9 Port GbE Web Smart Switch Note If you have no modules please skip this section Fig 2 1 In...

Page 17: ...a TP port of the switch and the other end is connected to a network aware device such as a workstation or a server Repeat the above steps as needed for each RJ 45 port to be connected to a Gigabit 10...

Page 18: ...The later is categorized into several classes by the distance it supports They are SX LX LHX XD and ZX From the viewpoint of connector type there mainly are LC and BIDI SC Gigabit Fiber with multi mod...

Page 19: ...1 0 m Fiber Cable 10 10 m TP to fiber Converter 56 Bit Time unit 1ns 1sec 1000 Mega bit Bit Time unit 0 01 s 1sec 100 Mega bit Table 2 2 Sum up all elements bit time delay and the overall bit time de...

Page 20: ...g The switch supports both port based VLAN and tag based VLAN They are different in practical deployment especially in physical location The following diagram shows how it works and what the differenc...

Page 21: ...not access VLAN1 and VLAN3 members but they could access VLAN4 members 3 VLAN3 members could not access VLAN1 VLAN2 and VLAN4 4 VLAN4 members could not access VLAN1 and VLAN3 members but they could ac...

Page 22: ...friendly way Publication date Nov 2012 Revision A1 14 9 PORT GBE WEB SMART PoE SWITCH Default IP Setting IP 192 168 1 1 Subnet Mask 255 255 255 0 Default Gateway 192 168 1 254 Ethernet LAN Fig 2 6 Ass...

Page 23: ...ter indicates the individual host in the network which the address of host refers to And the host identifier must be unique in the same LAN Here the term of IP address we used is version 4 known as IP...

Page 24: ...st below Class A 10 0 0 0 10 255 255 255 Class B 172 16 0 0 172 31 255 255 Class C 192 168 0 0 192 168 255 255 Please refer to RFC 1597 and RFC 1466 for more information Subnet mask It means the sub d...

Page 25: ...0000 1 1111111 All 0s 128 1 2 128 All 1s 128 1 2 255 Subnet Network Fig 2 8 In this diagram you can see the subnet mask with 25 bit long 255 255 255 128 contains 126 members in the sub netted network...

Page 26: ...k may look like 255 255 255 240 This means it is a small network accommodating a maximum of 15 nodes in the network Default gateway For the routed packet if the destination is not in the routing table...

Page 27: ...witch is suitable for the following applications The switch image is sample only Central Site Remote site application is used in carrier or ISP See Fig 2 10 Peer to peer application is used in two rem...

Page 28: ...Fig 2 11 Peer to peer Network Connection Fig 2 12 Office Network Connection Publication date Nov 2012 Revision A1 20...

Page 29: ...provided 1000Mbps Now 10G s Ethernet is under approving Although these Ethernet have different speed they still use the same basic functions So they are compatible in software and can connect each oth...

Page 30: ...ol or bridge relay entity Logical link control supports the interface between the Ethernet MAC and upper layers in the protocol stack usually Network layer which is nothing to do with the nature of th...

Page 31: ...SAP pair with some reserved values indicates some well known services listed in the table below 0xAAAA SNAP 0xE0E0 Novell IPX 0xF0F0 NetBios 0xFEFE IOS network layer PDU 0xFFFF Novell IPX 802 3 RAW pa...

Page 32: ...t MAC address The first bit of the first byte in the Destination address DA determines the address to be a Unicast 0 or Multicast frame 1 known as I G bit indicating individual 0 or group 1 So the 48...

Page 33: ...ividual address and the left most bit in the SA field is always 0 Length Type This field indicates either the number of the data bytes contained in the data field of the frame or the Ethernet type of...

Page 34: ...tart of frame Delimiter SFD DA SA and through the data field and FCS field in turn The followings summarize what a MAC does before transmitting a frame 1 MAC will assemble the frame First the preamble...

Page 35: ...This maximum time is traded off by the collision recovery time and the diameter of the LAN In the original 802 3 specification Ethernet operates in half duplex only Under this condition when in 10Mbp...

Page 36: ...eceiving frames are processed simultaneously This doubles the total bandwidth Full duplex is much easier than half duplex because it does not involve media contention collision retransmission schedule...

Page 37: ...that time the device will wait for a period of time known as an inter frame gap time to have the medium clear and stabilized as well as to have the jobs ready such as adjusting buffer counter updatin...

Page 38: ...not discards it and the MAC passes the frame to its client and goes back to the ready state 3 If the frame is too long If yes throws it away and reports frame Too Long 4 If the FCS of the received fra...

Page 39: ...rocess it in the same way as a basic normal frame For a VLAN enabled LAN all involved devices must be equipped with VLAN optional function At operating speeds above 100 Mbps the slotTime employed at s...

Page 40: ...same slot time the signals will collide referred to as collision The arbitrator will arbitrate who should gain the media The arbitrator is a distributed mechanism in which all stations contend to gain...

Page 41: ...perating in full duplex mode the distance can reach farther than half duplex because it is not limited by the maximum propagation delay time 512 bits time If fiber media is applied the distance can be...

Page 42: ...this time period is more than the aging time the entry will be marked invalid The vacancy is now available for other new MAC Both learning and forwarding are the most important functions in a switch B...

Page 43: ...t set another weight to the packet with a priority level say 2 4 and so on The WRR will transmit the packet with the weight So the packet of each priority level can be allocated a fixed bandwidth Band...

Page 44: ...always lies on the edge of the LAN For a layer 2 VLAN it assumes it is a logical subset of a physical LAN separated by specific rules such as tag port MAC address and so on In other words they can com...

Page 45: ...it is very hard to do Basically VLAN can afford offering at least 3 benefits move and change users reduce broadcast traffic and increase performance Security Besides VLAN can highly reduce the traffi...

Page 46: ...10 Tag Format VLAN Protocol ID 8100 is reserved for VLAN tagged frame User Priority 3 bits long User priority is defined to 7 0 0 is the lowest priority CFI Canonical Format Indicator 1 bit long It is...

Page 47: ...same VLAN with that PVID If the destination ports are members of the VLAN used by ingress port the packet will be forwarded Note VID can not be 0 or 4095 Ingress Rule Each packet received by a VLAN aw...

Page 48: ...d DA When a packet is received if it has a non zero VID then FID will offer the associated outgoing ports information to the packet In SVL VLANs use the same Filtering Database In IVL VLANs use differ...

Page 49: ...ch VLAN Usually we use 10 x x x as internal IP block Because there are total four VLANs in the network we must assign 4 IP blocks to each of them Name VID Network Address Marketing 2 10 1 2 0 24 Servi...

Page 50: ...nd your budget and the solution caused by the limitation of hardware performance may not be scalable If the item 2 is the case now you do not have to pay much more extra cost and can keep flexible acc...

Page 51: ...tation Here station may be a host or a router Link Aggregation called port trunking sometimes has two types of link configuration including static port trunk and dynamic port trunk Static Port Trunk W...

Page 52: ...fault Gateway 192 168 1 254 Password admin Table 4 1 When the configuration of your Web Smart Switch is finished you can browse it by the IP address you set up For instance type http 192 168 1 1 in th...

Page 53: ...displayed in green color and linked off ones will be in black For the optional modules the slots with no module will only show covered plates the other slots with installed modules would present modu...

Page 54: ...Configuration Monitoring Maintenance Root Publication date Nov 2012 Revision A1 46...

Page 55: ...ion RSTP IGMP Snooping Mirroring SNMP Loop detection Broadcast storm Protection POE QoS Filter Rate Limit Storm Control and QoS Broadcast Storm Protection PoE SNMP Loop Detection Mirroring IGMP Snoopi...

Page 56: ...em Configuration Function description Show system description firmware version hardware version MAC address serial number active IP address active subnet mask active gateway DHCP server and Lease time...

Page 57: ...this parameter Any alphanumeric character and null are acceptable Default Giga Switch DHCP Enabled Enable DHCP snooping Just tick the check box to enable it Default disable Fallback IP Address Users...

Page 58: ...that do not meet the routing rules predefined in the device If a packet does not meet the criteria for other pre defined path it must be forwarded to a default router on a default path This means any...

Page 59: ...and Flow Control Others you could set the power saving mode for switch power consumption Fig 4 4 Port Configuration Parameter description Enable Jumbo Frames This function support jumbo frames of up...

Page 60: ...llowing table summarized the function the media supports Media type NWay Speed Duplex 1000M TP ON OFF 10 100 1000M Full for all Half for 10 100 1000M Fiber ON OFF 100 1000M Full In Auto Speed mode no...

Page 61: ...e port of a port based VLAN will be accepted No filtering criterion applies in port based VLAN The only criterion is the physical port you connect to For example for a port based VLAN named PVLAN 1 co...

Page 62: ...escription The VLAN membership configuration for the selected switch can be monitored and modified here Up to 4096 VLANs are supported This page allows for adding and deleting VLANs as well as adding...

Page 63: ...e it Port Port number VLAN aware Enabled Discard other VLAN group packets only forward this port joined VLAN group packets Packet Type All Forward all tagged and untagged packets Tagged Only Forward t...

Page 64: ...the existed port based VLAN group If you are in tag based VLAN it will show the ID VID Member of the existed tag based VLAN group The switch can store the configuration of port based VLAN and tag bas...

Page 65: ...your VLAN mode selection Member In modify function this is used to enable or disable if a port is a member of the new added VLAN Enable means it is a member of the VLAN Just tick the check box beside...

Page 66: ...n protected port A destination address on an data packet is matched with a physical address on said layer 2 switch and a forwarding map is generated for the data packet based upon the destination addr...

Page 67: ...into a logical port then this logical port s bandwidth would be as three times high as a single Fast Ethernet port s Function name Aggregation Configuration Function description Display the current s...

Page 68: ...port The switch with the highest priority lowest numeric value becomes the STP root switch If all switches have the same priority the switch with the lowest MAC address will then become the root swit...

Page 69: ...box beside the port x to enable RSTP protocol then press the Apply button to apply Edge Just tick the check box beside the port x to enable edge function Path Cost Path cost is the cost of transmitti...

Page 70: ...Just tick the check box to enable this function Default disable Router Ports Just tick the check box beside the port x to enable router ports then press the Apply button to start up Default none Unreg...

Page 71: ...Publication date Nov 2012 Revision A1 63 After IGMP Enabled function start up then user can tick the check box to enable this function Default enable...

Page 72: ...and Port B are Source Ports and Port C is Mirror Port respectively thus the traffic passing through Port A and Port B will be copied to Port C for monitor purpose Parameter description Source Port Se...

Page 73: ...tion The switch supports a switch to turn on or off the SNMP agent If you set the field SNMP Enable SNMP agent will be started up If the field SNMP is set Disable SNMP agent will be de activated the r...

Page 74: ...is user definable with a maximum length of 15 characters and is case sensitive There is not allowed to put any blank in the community name string Any printable character is allowable The community na...

Page 75: ...es If you want to resume the locked port please find out the looping path and take off the looping path then select Unlock port and click on Apply to turn on the locked ports Fig 4 15 Loop Detection C...

Page 76: ...port When Port No is chosen and enable port s Loop detection the port can detect loop happens and port will be Locked If Loop did not happen port maintains Unlocked Unlock port When ticking the port...

Page 77: ...od of time which can be set After a configured time the switch will detect whether the broadcast packets received on the port still exceed the threshold If the broadcast traffic is still higher than t...

Page 78: ...red the Broadcast Strom Protection enable Unlock Time The period in seconds for which a port will be kept disabled in the event of a loop is detected and the port action is to shut down the port State...

Page 79: ...of the PD and it will stop supplying the power once the power required by the PD excesses the Class Short Circuit or over temperature occurs Fig 4 17 PoE Setting Parameter description PoE Enabled To e...

Page 80: ...l affect the priority of VLAN tag Based on priority of VLAN tag it can arrange 0 7 priorities priorities can map to 4 queues of the switch low normal medium high and possess different bandwidth distri...

Page 81: ...unused DSCP can form total 64 0 63 kinds of Traffic Class based on the arrangement of 6 bit field in DSCP of the IP packet In the switch user is allowed to set up these 64 kinds of Class that belong...

Page 82: ...s of priority traffic as mentioned above user can set up any of Queue low normal medium high In default Priority 0 63 are mapping to Queue high Fig 4 20 DSCP Setting Publication date Nov 2012 Revision...

Page 83: ...Monitoring There are six functions contained in the monitoring function IGMP Status PoE Status Ping Detailed Statistics RSTP Status Monitoring Statistics Overview Publication date Nov 2012 Revision A1...

Page 84: ...traffic statistics for all switch ports Fig 4 3 1 Statistics Overview for all ports Parameter description Tx Rx Bytes The number of received and transmitted bytes per port Tx Rx Frames The number of r...

Page 85: ...Fig 4 3 2 Detailed Statistics for each port Parameter description Rx Packets The counting number of the packet received RX Octets Total received bytes Rx High Priority Packets Number of Rx packets cl...

Page 86: ...itted broadcast packet Tx Multicast Show the counting number of the transmitted multicast packet Tx Broad and Multicast Show the counting number of the transmitted broadcast with multicast packet Tx E...

Page 87: ...good and bad packets transmitted Rx CRC Alignment Number of Alignment errors and CRC error packets received Rx Undersize Number of short frames 64 Bytes with valid CRC Rx Oversize Number of long fram...

Page 88: ...tch Hello Time Show the current hello time of the root bridge Hello time is a time interval specified by root bridge used to request all other bridges periodically sending hello message every hello ti...

Page 89: ...queries received V1 Reports When a host receives a group membership query it identifies the groups associated with the query and determines to which groups it belongs The host then sets a timer with...

Page 90: ...t identifies the groups associated with the query and determines to which groups it belongs The host then sets a timer with a value less than the Max Response Time field in the query for each group to...

Page 91: ...PD Class Each PD is classified according to a class that defines the maximum power the PD will use The PD Class shows the PDs class Five Classes are defined Class 0 Max power 15 4 W Class 1 Max power...

Page 92: ...turned OFF Power budget exceeded The total requested or used power by the PDs exceeds the maximum power the Power Supply can deliver and port s with the lowest priority is are powered down No PD dete...

Page 93: ...et up a Target IP address to ping Count Use drop down menu to set number of echo requests to send Four type of number can choose there are 1 5 10 and 20 Default 1 Time Out in secs Use drop down menu t...

Page 94: ...s Show the active target IP address Status Show the result of the ping status Received replies Show the received replies number of times Request timeouts Show the timeout of request Average Response t...

Page 95: ...intenance There are five functions contained in the maintenance function Warm Restart Factory Default Maintenance Software Upgrade Configuration File Transfer Logout Publication date Nov 2012 Revision...

Page 96: ...software you have to reboot the device to have new configuration take effect The function being discussed here is software reset Function name Warm Restart Function description Reboot the switch Rebo...

Page 97: ...gs will be restored to the factory default values when Factory Default function is performed If you want to restore all configurations including the IP address setting to the factory default please pr...

Page 98: ...e Function name Software Upgrade Function description You can just click Browse button to retrieve the file you want in your system to upgrade your switch Fig 4 27 Software Upgrade Publication date No...

Page 99: ...You can backup your switch s configuration file into your computer folder in case accident happens In addition uploading backup configuration file into a new or a crashed switch can save much time an...

Page 100: ...rowser the switch will automatically have you logout Besides this manually logout and implicit logout you can set up the parameter of Auto Logout Timer in system configuration function to explicitly O...

Page 101: ...iguration on Computer C 2 The uplink connection function fails to work The connection ports on another must be connection ports Please check if connection ports are used on that 9 Port GbE Web Smart S...

Page 102: ...ts Any ports can be in disable mode force mode or auto polling mode Supports Head of Line HOL blocking prevention Supports broadcast storm filtering Web based management provides the ability to comple...

Page 103: ...on Mode 10 100Mbps support full or half duplex 1000Mbps support full duplex only Transmission Speed 10 100 1000Mbps for TP 100 1000Mbps for Fiber Full Forwarding Filtering Packet Rate PPS packets per...

Page 104: ...D mm Comply with FCC Part 15 Class A CE Mark Approval Management Software Specifications System Configuration Auto negotiation support on 10 100Base TX ports Web browser can set transmission speed 10...

Page 105: ...ENTIFIER switch 7 gesmsw24LProduces OBJECT IDENTIFIER gesmsw24LProductId 1 gesmsw24LIllegalLogin TRAP TYPE ENTERPRISE gesmsw24LProductId DESCRIPTION Send this trap when the illegal user try to login t...

Reviews: