Repotec RP-170508K User Manual Download Page 2

 

Chapter 4: 

Hardware Troubleshooting 

This chapter contains information to help you solve problems.    If the 
Switch is not functioning properly, make sure the Switch was set up 
according to instructions in this manual. 

 

1. 

The Power LED is not lit 

Solution: 
a. 

Check if the DC power adapter is well connected. 
Try to unplug and plug back the power adapter to 
the LAN Switch or try another power adapter. 

b. 

Check if the DC power source is in good condition. 

2. 

The Link LED is not lit 

Solution: 
a. 

Make sure the Switch configuration is consistent 
with the connecting device 

b. 

Check the cable connections. 

c. 

Make sure the cable distance between the Switch 
and other IEEE802.3 compatible network device 
should not exceed 100 meter. 

3. 

Performance is bad 

Solution: 

a.  Check the full duplex status of the Ethernet 

Switching.    If the Ethernet Switching is set to full 
duplex and the partner is set to half duplex, then 
the performance will be poor. 

b. 

Make sure the cable between the switch and other 
IEEE802.3 compatible network device is Category 
5 UTP at 100Mbps operation. 

4. 

Some stations can not talk to other stations located on the other 

port  

Solution: 

a. Check status of the Link LED to make sure the link is 

correct. 

b.  Make sure that the workstation’s network 

configuration is correct, modify the network 
configuration of workstation if need. 

c. Please reset the switch if need. 

 

 

Chapter 5: 

Specifications 

z

 

Standard:  

IEEE802.3 10Base-T Ethernet 

IEEE802.3u 100Base-TX Fast Ethernet 

z

 

Network Media:   

100Base-TX – UTP/STP category 5 cable 

10Base-T – UTP/STP category 3 or 5 cable 

z

 

Connector: 

STP RJ-45 port for 10/100Mbps TX 

z

 

LED indicators:   

System  –  Power LED.  

Individual port – link/activity LEDs 

z

 

Dimension:

 160mm(L) x 83mm(W) x 26mm(H) 

z

 

Temperature: 

 

Operating –  0

 to 45

 

     

Storage –    -20

 to 70

 

z

 

Humidity:  

Operating –    10% to 90% RH     

Storage –    5% to 90% RH 

z

 

Input Power Requirement:

 100 - 240VAC, 50 – 60Hz 

z

 

Certification:

 FCC Part 15 Class A, CE 

 

 

(P/N:

 

41NE-170508KB-A04) 

 
 
 
 
 

5/8-port 10/100Mbps   

Nway Fast Ethernet Switch

 

 

 
 
 

User Manual 

 
 

4

5