background image

Switch 1 : On  -> Forced Mode

                 Off -> Auto Negotiation mode
Switch 2 : On  -> LLR enable
                 Off -> LLR disable

1 2

o n

12

on

 

Switch 

There is a two pin DIP switch on the module which 

define as switch 1 and switch 2: 
Switch 1: Fiber mode switch 
  When the switch was turned to “On”, it means that 

the fiber was turned to forced mode, and “Off” for 

auto-negotiation mode. 

Note: 

Be sure the opposite end is using the same setting (forced or Auto-negotiation). And 

when using two converters at the same time, the two converters MUST set to forced 

mode.

 

Switch 2: LLR 
  When the switch was turned to “On”, it means that 

the LLR was enabled and “Off” for disabled. 

Note: 

When using two converters, don’t enable the both device’s LLR function at the 

same time.

 

10 

Summary of Contents for RP-1000C1

Page 1: ...1000Base T to 1000Base SX LX Gigabit Ethernet Media Converter Quick Installation Guide ...

Page 2: ...requency energy and if not installed and used in accordance with this user s guide may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may ...

Page 3: ...E 802 3ab and IEEE 802 3z 1000BASE TX and 1000BASE SX LX standards Product Features One channel media conversion between 1000BASE TX and 1000BASE SX LX Fiber media allows multi mode fiber and single mode fiber using SC connector Link Pass Through function Auto negotiation of duplex mode on TX port Auto MDI MDI X for TX port Full wire speed forwarding rate Front panel status LEDs Used as a stand al...

Page 4: ...ts 1 The ambient temperature should be between 32 and 104 degrees Fahrenheit 0 to 40 degrees Celsius 2 The relative humidity should be less than 90 percent non condensing 3 Surrounding electrical devices should not exceed the electromagnetic field RFC standards for IEC 801 3 Level 2 3V M field strength 4 Make sure that the equipment receives adequate ventilation Do not block the ventilation holes ...

Page 5: ... plug into a standard AC outlet Installing in a Chassis The Converter can be fit into any of the expansion slots on a special designed chassis First install the converter onto a carrier supplied with the chassis Step 1 Unscrew and pull out the media converter board Step 2 Plug in the media board to any of the vacant slot Step 3 Fit the converter onto the carrier and use the screw to secure it 5 ...

Page 6: ...controlled through Web Browser SNMP and terminal emulation program The management module will detect the default reset on the DIP switches and display out the status also the management module can control the function through the chassis system NOTE To control the function in a working station need to collocate together with optional Chassis System and Management Module 6 ...

Page 7: ... you instant feedback on status of the converter LEDs State Indication Power PWR Lights on Power on Lights off Power off Link and Activity LINK ACT Lights on Linking Lights Blinking Data transmitting and receiving Lights off Not Linking 7 ...

Page 8: ...her end will know that there is linkage problem exist There is a default LLCF setting on this converter The table below shows how LLCF function is working Fib e r Co p p e r T X RX Fib e r Co p p e r T X RX RXT X RX T X Gig a b it S witc h Gig a b it S witc h LINK 1 LINK 2 LINK 3 LINK 4 Ca b le 1 Ca b le 2 Ca b le 3 Ca b le 4 Ca b le 5 Me d ia Co nverte r A Me d ia Co nverte r B Link Status Discon...

Page 9: ... Fiber Copper T X RX Gigabit Switc h LINK 4 LINK 1 Cab le 1 Cab le 2 Media Converter B Fiber Copper T X RX Gigabit Switc h LINK 2 LINK 3 Cab le 3 Cab le 4 Media Converter A Copper Copper Link Status Disconnect Link 1 Link 2 Link 3 Link 4 Cable 1 Off Off Off Off Cable 2 Off On On Off Cable 3 Off Off Off Off Cable 4 Off Off Off Off NOTE If connecting two converters with LLR function in both end it i...

Page 10: ... it means that the fiber was turned to forced mode and Off for auto negotiation mode Note Be sure the opposite end is using the same setting forced or Auto negotiation And when using two converters at the same time the two converters MUST set to forced mode Switch 2 LLR When the switch was turned to On it means that the LLR was enabled and Off for disabled Note When using two converters don t enab...

Page 11: ...pair STP up to 100m 1000BASE SX 50 125μm multi mode fiber optic cable up to 550m 1000BASE LX 9 125μm or 10 125μm single mode fiber optic cable up to 70km Dimensions L120 W88 H25 mm Weight 300 g Power External power adaptor 9Vdc 0 7Amp Media Interface RJ 45 SC EMI Compatiblity FCC Class A CE Certification Class A VCCI Class A Temperture Storage 10 C 70 C Operating 0 C 40 C Humidity 10 90 non conden...

Page 12: ...ent distance range for the fiber port TX port Connector Type Cabling Segment Distance RJ 45 Copper Wire Max 100 m FX port Connector Type Cabling Segment Distance SC Multi Mode Fiber Max 550 m SC Single Mode Fiber Max 10 km SC Single Mode Fiber Max 20 km SC Single Mode Fiber Max 50 km SC Single Mode Fiber Max 70 km P N 29071500MC10010 Rev C1 01 12 ...

Reviews: