Operation

The Easy-in is always in standby mode. The operation of the motorised  
sliding door is currently in standby mode.

Operating the sliding door

Press the arrow keys (1 or 2) to move the sliding door in the direction  
of the arrows. You must keep the respective arrow key pressed here.  
The corresponding LED (3) lights up in green at the same time. 

If you let go of the arrow key, the sliding door movement is interrupted  

immediately. When closed, the sliding door initially moves in the opposite 

 

direction and is then brought to a halt. Both LEDs (3) then flash in green.  

If there is resistance when the sliding door is moved, the movement is  
stopped and the door moves a little in the opposite direction and the  
two LEDs light up in red. After the obstacle has been removed and an  
arrow key pressed repeatedly, the door can be operated again  
(as described above).

If there is resistance when the door is being closed (protection against  
getting stuck), the door moves in the opposite direction and is then brought  

to a halt. Both LEDs flash in green. Press one of the arrow keys once more 

 

to operate the door again.

Electricity failure

Should the power for the bathtub be cut at any time (e.g. due to electrical  
failure) and be re-commissioned (power supply functions again), one of  the 
two arrow keys („Open“ or „Close“) must be held pressed until the door is  
fully open (the door is referenced and the zero point set).

1

3

2

Safety information

Danger to life! Danger of electric shock!

When taking a bath or showering, no electrical devices may be 

 

operated in the bathtub or its proximity. Any contact between  

an electrical device which is plugged in and water can cause a fatal  
electric shock.

Children may not use the bathtub unsupervised.

If older or handicapped persons who have a limited scope of movement  
use the bathtub, they should exercise special care.

Normally, anybody whose cardiovascular system, metabolism and nervous 
system copes with normal everyday stress can bathe. If you have any  
doubts, consult a doctor.

Do not use the bath if you have a cold, an infection, ulcers, suppurating 

wounds or inflammations until they are fully healed. Likewise after alcohol 

consumption or directly after eating.

The specialist companies and the first owner of the bathtub provide the 

 

subsequent owners and users with the operating instructions.

Table of contents

Safety information 

2

Operation 

3

Keylock (child safety device) 

3

Overview of the operator panel alarm indications 

4

Care instructions for 

repa

BAD Easy-in 

7

Care instructions for 

repa

CLEAR coated glass partitions 

7

Warranty card 

8

Summary of Contents for Easy-in

Page 1: ...ting instructions carefully before using the Easy in Make sure that you observe the care instructions repaBAD cannot be held liable for damages caused by inappropriate use BEDEASYIN E 08 2009 repa BAD GmbH Operating instructions Easy in ...

Page 2: ...ailure Should the power for the bathtub be cut at any time e g due to electrical failure and be re commissioned power supply functions again one of the two arrow keys Open or Close must be held pressed until the door is fully open the door is referenced and the zero point set 1 3 2 Safety information Danger to life Danger of electric shock When taking a bath or showering no electrical devices may ...

Page 3: ...e bathtub the door is not fully closed Water supply interrupted the door can only be moved in the Closed direction Drain off water or close the door Zu Auf Constantly red when the key is pressed Bathtub filled Opening not possible Drain off water fully wait approx 1 minute Parallel orange flashing whilst the key is pressed Child safety device activated Deactivate child safety device Keylock child ...

Page 4: ...cial cleaner art no RR Repabad s acrylic material maintenance set art no PF is suitable for the elimination of minor scratches in the acrylics Treat the seal in accordance with the frequency of use with sealant cleaning agents Care instructions for repaCLEAR coated glass partitions Do not use concentrated cleaning agents containing vinegar or citrus stainless steel cleaners micro fibre cloths or s...

Page 5: ...arts for the repaBAD Easy in supplied by us provided the care instructions are observed and it is used correctly and carefully in accordance with our general terms and conditions of use The warranty period for the Easy in technology and electronics is 2 years This warranty begins on the day of delivery by repaBAD Any possib le claim must be notified to the specialist fitter from whom our product w...

Reviews: