9.0 Adjustment Components
LED Indicator Functions
ERROR
System fault
TEMP
Over
temperature
SYNC
Mains synchronisation fault
I-Max
Current limit reached ie current regulator active
LOAD
Impedance fault / peak current reached
MAX
Max. adjustment limit reached
INIT
Initialisation
phase
READY
Ready to operate
ENABLE Enable
IN1
External Input 1 (Reserved)
IN2
External Input 2 (Reserved)
S2
S2 = 1
S2 = 2
S2=3
P1 =Umin/coarse
P2 = Umin/fine
Imin/coarse
Imin/fine
Ramp up
Ramp down
times
P3 = P-Characteristic voltage regulator
P4 = P-Characteristic current regualtor
Selector Switch S1
S1/1 - OFF = Phase angle control ON = Full wave control
S1/2 -
S1/3 -
Reserved for curent controller
S1/4 -
S1/5 – OFF = 0...20 mA
ON = 4...20 mA (Setpoint)
S1/6 - OFF = I/U-Regulation
ON = Power regulation
S1/7 - OFF = without data interface
ON = with data interface
S1/8 - OFF = Reserved
Selector Switch S2
0 = Normal operation (Regulator)
1 = Adjustment Umin
2 = Adjustment Imin
3 = Adjustment ramp up/down times
4 = Reserved
5 = Uncontrolled operation (no regulation / no current limiting)
6-E = Reserved
F = Reinstate factory settings
RESET = System reset-Button
SETUP = Enter new parameters
ON
OFF
1
2
3
4
5
6
7
8
ERROR
ENABLE
TEMP
SYNC
I-max
LOAD
MAX
INIT
READY
IN1
IN2
P1
P2
P3
P4
S1
U-max
I-max
S2
RESET
SETUP
0
1
2
3 4 5 6 7
8
9 A
B C
D
E
F