TROUBLE SHOOTING
8
CONDITION
PROBABLE CAUSE
CORRECTIVE ACTIONS
Pump Fails to Start or
Operate
Loose Connection
Ensure that pump is correctly plugged into
the outlet.
Incorrect Voltage / Amps
Check power and correct connection.
Check to see if breaker has tripped.
Reset breaker or replace with correct
beaker size under local electrical code.
Tripped Motor Protector
Check if pump is completely submerged.
Ensure the liquid temperature being
pumped is below 50°C
Burned out Motor
Consider to Replace Pump
Fails to Deliver Full
Output / Restricted
Flow
Restricted Flow
Check discharge hose / pipe for any
obstruction. Clear out the obstruction.
Worn Out or Damaged
Impeller
Change the Impeller
Strainer is clogged
Remove debris
Airlock
Disconnect the hose and run the pump to
ensure it is filled with water.
Tilt the pump slightly and run the pump.
You may see a bubble blow. Straighten
the pump and continue running it for few
minutes.
Reconnect the hose and continue to run it
for another 10 minutes. The pump should
be ready for use.
PRODUCT DISPOSAL
9
Properly dispose the product in accordance with your local waste disposal program.
Please record the following information for future reference:
Model Number:
Serial Number:
Purchase Date: