Renova USX500-01 Assembly Manual And Operating Instructions Download Page 5

 

15 

Model with IO-Link 

 

-

 

SSC1 / 2/4: switching of signal channels  

-

 

MDC: distance value or counter switch (selectable)  

-

 

Quality: the quality bit signals a weak echo signal  

-

 

Alarm: the alarm bit signals a problem with sensor configuration or functionality   

-

 

Scale: power factor of ten, applicable to the Measurement Data Channel (MDC) value 

Available commands: learning commands, activation / deactivation of the sensor element, Find 
Me (Sensor location) and more. 

Available parameters: switching point, switching hysteresis, output function, time filters, beam 
formation, measured value filter, analog output characteristic, pin 5 function, LED status indicators 
and more.  

Additional data available: Counter, start cycles, operating hours, device temperature, operating 
voltage, histograms.  

 

allignement aid 

 

The retroreflective and barrier version is equipped with an indication of 
correct alignment integrated in the Teach-In at level 1. This function 
indicates the intensity of the signal received. 

Sensor alignment: the faster the flashing, the stronger the signal 

 

 

 

 

Summary of Contents for USX500-01

Page 1: ...Sensore di diametro ad ultrasuoni Ultrasonic diameter sensor Manuale di montaggio e istruzioni d uso Assembly manual and operating instructions ITA ENG...

Page 2: ...e 13 warnings page 13 assistance page 13 description page 14 model with IO Link page 15 alignment aid page 15 assembly procedures page 16 wiring diagram page 17 Teach In instruction for use page 18 in...

Page 3: ...arning READ THE INSTRUCTIONS AND WARNINGS PRESENT IN THIS MANUAL CAREFULLY AND KEEP THEM FOR FURTHER REFERENCES FOR THE DURATION OF THE PRODUCT IN THIS MANUAL THERE ARE IMPORTANT INSTRUCTIONS CONCERNI...

Page 4: ...the sensor surface extremely short blind field of 20 mm with a radius of up to 1000 mm Consistent operation thanks to resistance to interference detection of transparent shiny and multicolored objects...

Page 5: ...e Sensor location and more Available parameters switching point switching hysteresis output function time filters beam formation measured value filter analog output characteristic pin 5 function LED s...

Page 6: ...ator is free to mount the sensor wherever he wants to have a reading ATTENTION In order to avoid staggered readings of the diameter we do not recommend installing it vertically near the exit area of t...

Page 7: ...ATTENTION Disconnect the power supply before mounting the sensor Voltage supply according to UL 1310 Class 2 oR the device must be protected by an external R C or by a listed fuse max nominal value 3...

Page 8: ...Remote Teach In is always possible does not deactivate after 5 min If the metal tool remains for more than 12 seconds Teach in does not suffer variations How to perform the calibration Place a metal...

Page 9: ...19...

Page 10: ...20 Index of manual revision note Rev n Rev Date Description of the changes made...

Page 11: ...21...

Page 12: ...Renova srl viale Rimembranze 93 20099 Sesto San Giovanni MI Italy tel 39 02 2700 7394 fax 39 02 2570 8635 www renova srl com email support renova srl it...

Reviews: