8
BATTERY STORAGE AND DISPOSAL
▪
Store the batteries separately from the product
▪
Store the batteries at temperatures between 15°C and 20°C (59°F and 68°F)
▪
Always check and follow your applicable regulations before disposing of a battery
malfunctions diagnosis
In case of anomaly or not functioning of the
moviroll
system, error messages will be shown in red on the display:
POSSIBLE ERROR MESSAGES
SOLUTIONS/REMEDIES
E01
Motor already powered at start (forward gear)
Turn off/on with throttle in zero position
E02
Motor already powered at start (backward gear) Turn off/on with throttle in zero position
E03
Battery tension too low
Charge the battery
E04
Battery tension too high
Use another battery and contact Renova
E05
Accelerator handle not at position 0 at start
Turn off/on with throttle in zero position
E06
Broken accelerator handle
Replace the throttle
E07
Overheating
Cool the engine and the electronic board
E08
Programming error eprom
Turn off/on.
If the problem persists, contact Renova
E09
Error on con
trol’s power
Turn off/on.
If the problem persists, contact Renova
E10
Resolver not connected
Turn off/on.
If the problem persists, contact Renova
PLEASE NOTE:
Please see warranty conditions on the warranty sheet.
moviroll display