The battery status LEDs (see the picture at page 10):
GREEN LED
charged battery
YELLOW LED
50% battery charge (when active)
RED LED
discharged battery
ATTENTION!
Use the
moviroll
only when GREEN and YELLOW LEDs. Do not use the
moviroll
with RED battery status
LED to avoid any irreparably damage to the electronic unit and the battery. With RED LED recharging the
battery is mandatory before using the
moviroll
again.
BATTERY RECHARGE
▪
Push the switch into the OFF position
▪
Remove the battery from the chassis (as in the picture) and
place it in a suitable area before charging it
▪
Connect the battery to the battery charger through the connector
▪
Connect the battery charger to the mains supply.
▪
Two red LEDs on the battery charger now turn on; one LED
indicates that the battery charger is under tension, the other LED
indicates that the battery is charging.
▪
The estimated time of charging is about 4 hours (maximum time
needed for a full recharge of the battery). The battery is full
recharged when one of the two LEDS will turn green.
▪
Please leave the battery under charge for about 30 minutes to
stabilize the tension of the cells.
▪
After recharging the battery disconnect the battery from the
charger, then the charger from the mains supply. The red LED of
the charger will remain lit for a bit of time even if cable
unplugged.
PLEASE NOTE:
In the case of battery charger equipped with a single LED, this will be lit red and turn green at completed recharge.
ATTENTION!
For the full recharge of the battery, please use the battery charger supplied with the
moviroll
battery
roll pusher
.
To not damage the battery please do not use different battery chargers.
BATTERY HANDLING PRECAUTIONS
▪
Do not dissemble, crush or puncture a battery
▪
Do not dispose of a battery in fire
▪
Do not immerse the unit in any liquid
▪
Do not expose a battery to temperatures above 40°C (104°F) and below 5°C (41°F)
▪
Do not use a damaged battery
▪
Do not leave batteries unused for extended periods of time, either in the product or in storage
▪
BATTERY STORAGE AND DISPOSAL