Load Mode Options
1
2
3
4
Programming Load Terminal
1. This screen is displaying the current Load Mode.
2. To enter screen 2 press and hold the Enter button. This screen will allow you to change
the load mode.
3. To change the load mode press the up or down button.
4. Once you have selected the desired load mode press the Enter button to save the setting.
5. To exit the programming setting press the left button.
Setting
Mode
Description
0
Automatic(On/Off)
Time control
15
Manual
16
Test
17
24Hr
The load will turn on at night when the solar
panel is no longer producing any power
after a short time delay. The load will turn
off when the panel starts producing power.
When the panel is no longer producing
power the load will be ON for 1-14 hours
or until the panel starts producing power.
Used to troubleshoot load terminal (No
Time Delay). When voltage is detected
load will be off and when no voltage is
detected load will be on.
In this mode, the user can turn the Load
On/Off by pressing the Enter button at any
time.
The load will be on for 24 hours a day.
1-14
21