background image

Version 1.0

FOR PGH INVERTER SERIES

MONITORING 

SCREEN

Summary of Contents for RMS-PGH

Page 1: ...Version 1 0 FOR PGH INVERTER SERIES MONITORING SCREEN ...

Page 2: ...peration and malfunction of a peripheral device Contamination with hazardous substances diseases vermin or radiation Alterations to the product without express written consent from the manufacturer Must be properly ventilated to ensure no build up of explosive gases prior to installation Force majeure including fire typhoon flood earthquake war and terrorism Important Safety Instructions Please sa...

Page 3: ...efore make sure there are not flammable materials or gases near installation The inverters are suitable for 12V Battery Banks ONLY ALWAYS make sure inverter is in OFF position and disconnect all AC and DC connections when working on any circuit associated with the inverter NEVER connect the AC output of the unit directly to an Electrical Breaker Panel Load Centre which is also fed from the utility...

Page 4: ...ition Only in the REM position will the RMS PGH be able to manually turn the inverter ON OFF in addition to monitoring the inverter Changing the frequency 50 60Hz or the power mode Normal Eco will need to be done physically on the inverter The inverter then needs to be rebooted for the changes to take effect on the monitoring screen In order to read the parameters of the inverter correctly 1 The s...

Page 5: ...mportant Safety Instructions General Information Product Overview Identification of Parts Dimensions Installation Operation LCD User Interface Overview Voltage V Current A Watts W Frequency Hz Error Code Normal ECO Mode LED Indicators Troubleshooting Technical Specifications ...

Page 6: ...es In addition use the power button to manually shut down the inverter at your convenience The RMS PGH is the perfect monitor companion to optimize any solar system Plug and Play Simply connect the monitoring screen to the PGH inverter using an RJ12 and RJ45 communication cable for real time monitoring Accurate Readings Obtains input and output readings directly from the communication port on the ...

Page 7: ...rview LCD Screen Input output Parameter Switch Key Main On Off power key LED Status Lights Front Cover Plate Mounting Holes RJ45 Communication Port RJ12 Communication Port Identification of Parts RMS PGH ON ELEC ERR ...

Page 8: ...07 Dimensions 110 0mm 4 3in 87 5mm 3 4in 1 3in 0 8in 2 8in 70 0mm 2 3in 58 5mm 31 8mm 19 5mm RMS PGH ON ELEC ERR ...

Page 9: ...toring screen to the COMM port for data transmission The RJ12 Communication Cable 5m 16 4ft is used to connect the monitoring screen to the REMOTE port for power supply RJ12 Communication Cable Self tapping Screws 4 The Self tapping Screws M2 9 13mm are used to fix the monitoring screen on the mounting surface 08 ...

Page 10: ...body of the meter CAUTION WARNING Please choose a clean dry protected and easily accessible indoor location to install the monitoring screen It is recommended to mount the monitoring screen at eye level for easy access to the battery information and operation buttons The RJ45 RJ12 Communication ports on the monitoring screen are accessible from the back of the unit Clearance of at least 2 inches 5...

Page 11: ...creen on the mounting surface with a jigsaw You may also use the cut out dimension specified after Step 2 3 Pre drill four screw holes on the mounting surface with a drill 4 Place the monitoring screen into the cut out area and align the mounting holes on the monitoring screen with the pre drilled screw holes 5 Affix the monitoring screen on the mounting surface with the included four self tapping...

Page 12: ...11 3 2 ...

Page 13: ...12 Cutout Dimensions L x H x W 86 7 x 58 02 x 19 8mm 4 5 ...

Page 14: ...13 6 7 ...

Page 15: ... Eco will need to be done physically on the inverter The inverter then needs to be rebooted for the changes to take effect on the monitoring screen In order to read the parameters of the inverter correctly 1 The switch must be in the ON or REM position and the COMM port correctly connected to the RJ45 cable 2 The REMOTE port is correctly connected to the RJ12 communication cable RJ45 Communication...

Page 16: ...cation cables need to be connected correctly in order to read the parameters of the inverter correctly Changing the frequency or the power mode Normal Eco mode will need to be done on the inverter and then the inverter rebooted for the changes to take effect on the monitoring screen The following key allows you to switch between input and output parameters INPUT NOR Hz W OUTPUT ECO ...

Page 17: ...ates the AC Load Voltage Volts will be AC Voltage V Input Output Current A The real time current flowing from the inverter to the AC appliances Current will be AC amps Input Output W Watts W The real time watts flowing from the inverter to AC Appliances Watts is calculated based on AC Values Input Output ...

Page 18: ...the output frequency the DIP switch needs to be physically selected on the unit BEFORE turning on the inverter Frequency Hz Displays the frequency of the inverter output to operate AC appliance Input Output W W NOTE The RMS PGH will not calculate the watts below 100 watts Instead the following code will display depending on the watts ...

Page 19: ...he working mode To operate in ECO or Normal working mode the DIP switch needs to be physically selected on the unit BEFORE turning on the inverter The normal NOR icon will be on the left and the Eco Mode ECO icon on the right NOTE Under ECO mode the inverter senses the output for a load greater than 50W Loads under 50W will not be powered and the inverter will stay idle Normal ECO Mode NOTE The er...

Page 20: ...low Flash Troubleshooting Input voltage below 11V Error Code 01 ERR LED Lit Error Code 02 ERR LED Lit Input voltage is above 15V Use a multimeter to check the voltage of the battery bank Disconnect any loads if any and make sure you re only using 12V battery bank systems Use a multimeter to check the voltage of the battery bank Disconnect any loads and charge the battery back up Indicator Troubles...

Page 21: ...le is connected to the REMOTE port and the RJ45 communication cable is connected to the COMM port Monitor Screen does not turn on Monitor screen shutdown Inverter is short circuited Use a multimeter to check the voltage of the battery bank to make sure you re above 11V Disconnect loads if any and make sure you re only using 12V battery bank systems Use a multimeter to check the voltage of the batt...

Page 22: ... Current Accuracy Communication Port Display RJ45 RJ12 Backlit LCD 5VDC 30mA 1W 4 113 20 45 0 1V 0 1A Dimension Weight User Interface 2 key input 1 main power switch Mounting System 2 8 4 3 1 3 inch 70 110 31 8 mm 0 14 lbs 62 g Mounting Screw Certification FCC Part 15 Class B CE RoHS 2 9 13mm RJ45 Wire Length 16 4 Ft 5m RJ12 Wire Length 16 4 Ft 5m Model RMS PGH Wall Mount ...

Page 23: ... radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourag...

Page 24: ...909 287 7111 www renogy com support renogy com https www renogy cn support renogy cn CN 400 6636 695 苏州高新区科技城培源路1号5号楼 4 CA https ca renogy com supportca renogy com https au renogy com supportau renogy com AU JP https www renogy jp supportjp renogy com https uk renogy com supportuk renogy com UK https de renogy com supportde renogy com DE ...