![Renogy PWM10CC Manual Download Page 3](http://html1.mh-extra.com/html/renogy/pwm10cc/pwm10cc_manual_1442944003.webp)
2
2. Load Control Options
Press and hold the SET button for about
5 seconds
until the display starts flashing. Press the
SET button once again to select the one of the desired control options shown in
Table 1
. When
done selecting the desired option, wait until the display stops flashing. The load LED will come
on, which will indicate that you have selected an option.
No. for 10A CC
No. for 30A CC
Description of Work Mode
16
6.
Manually turn on/off load output with the SET button
17
7.
Test mode/Dusk-to-Dawn light control:
(1) Light turns on after no sunlight detected
(2) Light turn off after sunlight detected
Table 1.
Load control options
3. LED Indicators
Icon
Description
Green ON: Solar power is charging the battery
Green BLIKING: The system is over voltage
Green ON: Battery level is in the right range
Green SLOWLY FLASHING: Battery level is full
Orange ON: Battery level is low
Red ON: Load cut-off
Orange ON: The load output is on
Red SLOWLY FLASHING: Overload*
Red BLINKING: Load is short-circuit*
Table 2.
LED indicators
*Note:
The load amps is 1.25 times of the rated current for 60 seconds or the load amps is 1.5
times the rated current for 5 seconds. The output will shut off once there is an overload or short
circuit. Disconnect all of the equipment and then wait a few seconds before reconnecting
everything. Press the SET button and the controller will resume working after approximately 10
seconds, or in some instances, it may take a few moments longer.