Renogy PWM10CC Manual Download Page 3

2

 

 

2. Load Control Options

 

 

Press and hold the SET button for about 

5  seconds

 until the display starts flashing. Press the 

SET button once again to select the one of the desired control options shown in 

Table 1

. When 

done selecting the desired option, wait until the display stops flashing. The load LED will come 
on, which will indicate that you have selected an option.  
 

No. for 10A CC 

No. for 30A CC 

Description of Work Mode

 

 

16 

 

6. 

 
Manually turn on/off load output with the SET button 

17 

7. 

Test mode/Dusk-to-Dawn light control: 

(1) Light turns on after no sunlight detected 
(2) Light turn off after sunlight detected 
 

 

 

 

 

Table 1.

 Load control options 

 

 

3. LED Indicators

 

 

Icon 

Description 

 

 

 

Green ON: Solar power is charging the battery 
Green BLIKING: The system is over voltage

 

 
 

 

 
Green ON: Battery level is in the right range 
Green SLOWLY FLASHING: Battery level is full 
Orange ON: Battery level is low 
Red ON: Load cut-off 

 

 

 

 

Orange ON: The load output is on 
Red SLOWLY FLASHING: Overload* 
Red BLINKING: Load is short-circuit* 

 

Table 2.

 LED indicators

 

 
*Note:

 The load amps is 1.25 times of the rated current for 60 seconds or the load amps is 1.5 

times the rated current for 5 seconds. The output will shut off once there is an overload or short 
circuit.  Disconnect  all  of  the  equipment  and  then  wait  a  few  seconds  before  reconnecting 
everything. Press the SET button and the controller will resume working after approximately 10 
seconds, or in some instances, it may take a few moments longer. 
 

 
 
 
 
 