background image

14

Communication Diagram

RV-C Communication

1.   For REGO devices connected with RV-C daisy chain topology:

RV-C Daisy Chain Topology

Renogy ONE

Device 2

Device 1

Device N

RV-C

Communication

Cable

RV-C

Communication

Cable

RV-C

Communication

Cable

2.   For REGO devices connected with RV-C backbone topology:
For backbone topology, please contact our customer service through 

renogy.com/contact-us/

.

RV-C Backbone Topology

Renogy ONE

RV-C

Communication

Cable

RV-C

Communication

Cable

RV-C

Communication

Cable

RV-C

Communication

Cable

Device 2

Device 1

Device N

...

Drop Tap

Renogy ONE Communication Architecture

Energy Device Communication Connections

Summary of Contents for ONE M1

Page 1: ...VERSION A0 Renogy ONE M1 User Manual...

Page 2: ...region z Renogy reserves the right to change the information in the user manual without notice z Renogy ONE collects and uses your data in accordance with the Privacy Policy Copyright Renogy ONE M1 Us...

Page 3: ...roduct Overview 09 Wiring Diagram 11 Communication Diagram 12 Renogy ONE Communication Architecture 12 Energy Device Communication Connections 13 Preparation 15 Required Tools 15 Inspection 15 Mountin...

Page 4: ...ories 34 Power On O 36 Control External Loads 37 Troubleshooting 38 Frequently Asked Questions 39 Maintenance 41 Inspection 41 Cleaning 41 Storage 41 Emergency Responses 42 Fire 42 Flooding 42 Smell 4...

Page 5: ...mage including cracks dents deformation and other visible abnormalities before installation z Do not puncture drop crush penetrate shake strike or step on Renogy ONE z Do not open dismantle repair tam...

Page 6: ...ship it may cause damage to the ship s corrosive agents Please have Renogy ONE installed by a quali ed ship electrician CAUTION z Do not expose Renogy ONE to ammable or harsh chemicals or vapors z Ens...

Page 7: ...phone Key Features z All in one Smart Panel By connecting to a wide range of energy devices and smart home accessories via Bluetooth or Zigbee Renogy ONE allows you to track energy data and manage yo...

Page 8: ...08 Package Contents Package Contents Renogy ONE M1 1 Quick Guide 1 12V Power Cable 5m 1 M2 Screws 4 ST2 x 1 2 x 6 5 mm M4 Mounting Screws 4 ST4 x 2 x 13 mm...

Page 9: ...09 Product Overview Product Overview 2 1 3 4 5 No Part No Part 1 Power Button 4 Panel Switch 2 2 Touch Screen 5 Panel Switch 3 3 Panel Switch 1...

Page 10: ...rt 1 Mounting Holes 6 IN 3 External Load Input Terminal 2 IN 1 External Load Input Terminal 7 OUT 3 External Load Output Terminal 3 OUT 1 External Load Output Terminal 8 Power Port 4 IN 2 External Loa...

Page 11: ...1 Wiring Diagram IN1 IN2 CAN RS485 TYPE C OUT1 OUT2 IN3 OUT3 Negative Positive DC Load 30V DC 5A Communication 12V Power Supply 30V Power Supply Devices with RV C or RS485 communication Wiring Diagram...

Page 12: ...Energy Devices Motion Sensor Smart Plug Smart Relay Window Door Sensor Other Smart Accessories Zigbee Wi Fi Renogy ONE Wi Fi Cellular Network Bluetooth RS485 RV C To ensure good compatibility it is r...

Page 13: ...th BT 1 s Communication Cable BT 2 s Communication Cable Bluetooth BT 1 BT 2 Device 1 with Bluetooth Device 2 Device 3 Renogy ONE BT 2 s Communication Cable Bluetooth BT 2 Device 2 Device 1 Device N C...

Page 14: ...RV C Communication Cable 2 For REGO devices connected with RV C backbone topology For backbone topology please contact our customer service through renogy com contact us RV C Backbone Topology Renogy...

Page 15: ...crewdriver 2 Insulation Tape Skill Saw Inspection Please inspect Renogy ONE for any visible damage including cracks dents deformation and other visible abnormalities before installation All connector...

Page 16: ...tion or use an extension cable 22 AWG If you do not need to extend the 12V power cable please go to step 5 NOTE z Install Renogy ONE on a vertical surface z Mounting Renogy ONE requires installation h...

Page 17: ...iary one A reverse polarity contact will result in abnormal operations The length of the extension cable should not exceed 10 meters 32 8 feet 4 Strip part of the insulation o the extension cable and...

Page 18: ...n in Figure 1 1 7 and use a Phillips screwdriver to fasten the base cover with four M4 mounting screws through the mounting hole NOTE z That screws are driven in straight into the mounting holes to en...

Page 19: ...DC power supply of up to 16V otherwise Renogy ONE may be damaged z Please confirm the polarity of the DC power supply device before connection A reverse polarity contact will result in abnormal opera...

Page 20: ...ication cable should be less than 30 meters 98 4 feet INFO z Please read the user manual carefully before using Renogy Communication Hub z When Renogy BT 2 Bluetooth Module is connected to the main co...

Page 21: ...enogy Communication Hub NOTE z Ensure that Renogy Communication Hub is connected to the power supply z The length of the communication cable connecting the device to Renogy Communication Hub should be...

Page 22: ...for communication with the Backbone topology If you need to use the backbone topology for communication connections please contact us through renogy com contact us INFO z If a RV C bus is pre install...

Page 23: ...g selection please check with the RV manufacturer This user manual takes the Mini Clamp II plug 4 pin as an example z Different Drop Plugs follow different pinouts Please crimp the Drop Plugs on the D...

Page 24: ...liers 5 Locate the drop tap not included on the RV C bus that is the closest to the Renogy ONE installation location The drop taps are usually located above the entry door in the bathroom or under the...

Page 25: ...e installed in the RV please follow the steps below Recommended Accessories Communication Cable LP16 Plug 7 Pin to RJ45 Communication Adapter Cable NOTE z Please select the appropriate communication c...

Page 26: ...tallation hole 3 Unplug the LP16 Terminator Plug 7 Pin on the rst or last REGO device in the communication network 4 Insert the LP16 Plug 7 Pin to RJ45 Communication Adapter Cables into the communicat...

Page 27: ...20ft 3 6m 6AWG 21 30ft 9 6m 6AWG WARNING z For your safety please select cables that meet the specifications according to the actual use Battery Combiner Box Battery Combiner Box DC load 30V DC 5A 1...

Page 28: ...power supply device before connection A reverse polarity contact will result in abnormal operations z Please confirm the polarity of the load before connection A reverse polarity contact may cause ab...

Page 29: ...z After correct power cable connection and normal power on of the DC power supply Renogy ONE is automatically powered on Failed automatic power on indicates a fault on Renogy ONE For troubleshooting r...

Page 30: ...that the DC power supply cable and the cable that is connected to the positive pole of the load are connected to the same group of terminals For example IN 1 and OUT 1 are in a group WARNING z Make s...

Page 31: ...en the screws to avoid damage to the hatch IN 1 IN 2 CA N RS 48 5 TY PE C O UT 1 O UT 2 IN 3 O UT 3 IN 4 Insert the adapter cable connecting to the positive end of the DC power supply into the Renogy...

Page 32: ...en the 4 M2 screws through the mounting holes so that the Renogy ONE is xed on the base NOTE z Make sure that Renogy ONE is installed securely to prevent it from falling o 3 Align the snap on the back...

Page 33: ...ding via the activation wizard CAUTION z You can tap Skip in the upper right corner of the main interface on Renogy ONE to skip some of the wizard steps You can re complete the activation operations t...

Page 34: ...and set smart scenarios through the DC Home app CAUTION z Ensure both Renogy ONE and your phone where the DC Home app runs are connected to the Internet Add Devices Smart Accesories How to add devices...

Page 35: ...e good compatibility it is recommended to use Renogy energy devices and smart accessories INFO z For adding smart accessories to Renogy ONE via Zigbee resetting accessories is required For details ref...

Page 36: ...36 Power On O Power On O 3s Press and hold the Power Button on Renogy ONE for 3 seconds to power on o Renogy ONE...

Page 37: ...f Renogy ONE correspond to 3 panel relays respectively OFF ON 2 Press the panel switches to power on o external loads You can modify the above default settings or set more functions for the panel swit...

Page 38: ...near Renogy ONE Bluetooth within 10 meters in an open environment Zigbee within 50 meters in an open environment 2 The smart accessories have been connected to other devices Please initialize the smar...

Page 39: ...ation has been written into Renogy ONE system In the case of disconnection offline Renogy ONE can still receive information from the smart accessories and send instructions to the smart accessories 5...

Page 40: ...No 10 Does Renogy ONE support 5G Hz Wi Fi network No 11 Why does Renogy ONE need regular system updates Renogy has always been committed to providing customers with the best user experience And contin...

Page 41: ...y Dielectric grease repels moisture and protects the connector contacts from corrosion WARNING z Risk of electric shock Make sure that all power is turned o before touching the terminals on the Renogy...

Page 42: ...safe to do so Fire 1 Disconnect all cables connected to the Renogy ONE 2 Put out the re with a re extinguisher Acceptable re extinguishers include water CO2 and ABC WARNING z Do not use type D ammable...

Page 43: ...Owner name z Contact information z Order number z Purchase channel z Serial number z Brief description of the issue Visit renogy com to nd relevant documentation or get more support via Contact Us US...

Page 44: ...lock 12V DC Wireless Communication Wi Fi IEEE 802 11b g n 2 4GHz Bluetooth 2 1 4 2 and Bluetooth LE Zigbee IEEE 802 15 4 Protocols RV C Modbus Zigbee 3 0 Touch Screen 4 inches 480 x 480p White backlig...

Page 45: ...sions CAN RS485 TYPE C IN1 IN2 OUT1 OUT2 IN3 OUT3 181 8mm 7 16in 86 8mm 3 42in 107mm 4 21in 42 2mm 1 66in 28mm 1 1in 32mm 1 26in 17mm 0 67in 68mm 2 68in 77mm 3 03in 140mm 5 51in CAUTION z Dimensional...

Page 46: ...erference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television r...

Page 47: ...individual who can be identi ed from those data or from those and other information either in our possession or likely to come into our possession z Usage Data Usage Data is data collected automatical...

Page 48: ...your location if you give us permission to do so Location Data We use this data to provide features of our Service to improve and customise our Service You can enable or disable location services whe...

Page 49: ...our state province country or other governmental jurisdiction where the data protection laws may di er from those of your jurisdiction If you are located outside the United States and choose to provid...

Page 50: ...quest that we restrict the processing of your personal information z The right to data portability You have the right to be provided with a copy of the information we have on you in a structured machi...

Page 51: ...a liates services providers and third parties For more details on third parties we share data with please see the Service Providers section below Please contact us at support renogy com if you have an...

Page 52: ...e contents of this manual without notice Visit renogy com to find relevant documentation or get more support via Contact Us Join the Renogy Power Plus Community by downloading the DC Home App Find you...