17
Timer 1
LED Digital No.
Disable
n
Dusk-to-Dawn, Load will be on all night
0
Load will be on for 1 hour after a ten minute delay since sunset
1
Load will be on for 2 hours after a ten minute delay since sunset
2
Load will be on for 3 hours after a ten minute delay since sunset
3
Load will be on for 4 hours after a ten minute delay since sunset
4
Load will be on for 5 hours after a ten minute delay since sunset
5
Load will be on for 6 hours after a ten minute delay since sunset
6
Load will be on for 7 hours after a ten minute delay since sunset
7
Load will be on for 8 hours after a ten minute delay since sunset
8
Load will be on for 9 hours after a ten minute delay since sunset
9
Load will be on for 10 hours after a ten minute delay since sunset
10
Load will be on for 11 hours after a ten minute delay since sunset
11
Load will be on for 12 hours after a ten minute delay since sunset
12
Load will be on for 13 hours after a ten minute delay since sunset
13
Load will be on for 14 hours after a ten minute delay since sunset
14
Load will be on for 15 hours after a ten minute delay since sunset
15
Test mode
16
ON/OFF mode
17
Table 4-6
Load work mode
Timer 2
LED Digital No.
Disable
n
Load will be on for 1 hour before sunrise
1
Load will be on for 2 hours before sunrise
2
Load will be on for 3 hours before sunrise
3
Load will be on for 4 hours before sunrise
4
Load will be on for 5 hours before sunrise
5
Load will be on for 6 hours before sunrise
6
Load will be on for 7 hours before sunrise
7
Load will be on for 8 hours before sunrise
8
Load will be on for 9 hours before sunrise
9
Load will be on for 10 hours before sunrise
10
Load will be on for 11 hours before sunrise
11
Load will be on for 12 hours before sunrise
12
Load will be on for 13 hours before sunrise
13
Load will be on for 14 hours before sunrise
14
Load will be on for 15 hours before sunrise
15
Table 4-7
Load work mode
Notes: If Timer 1 is Dusk-to-Dawn (0), Test mode (16) or ON/OFF
mode (17), Timer 2 will be disabled (n).