MOTHERBO ARD  

INSTALLATION AND OPERATING INSTRUCTIONS 

I. 

General 

The HM1 Motherboard is available in various AC and DC  input voltages and can be 
configured with Solid-State or Relay Outputs. 

The model designation indicates the input voltage and output configuration as follows. 

Model HM1-XX-X

 

R

 = Relay Outputs, 

Blank

 = Solid-State Outputs 

3

 = 120 VAC, 

7

 = 24 VAC, 

23

 = 12 VDC, 

24

 = 24 VDC 

NOTE:  Solid-State outputs are available only on the Model HM1-23. 

II.  Installation Instructions 

1.

 

Using four #8 screws, fasten the Model HM1 Motherboard to a solid surface. 

2.

 

Make the appropriate connections to the 

PWR+

PWR-

, and 

EARTH

  terminals on 

terminal strip 1 (

TS1

) as shown in the table below. 

Power Input - Terminal Strip 1 (TS1) 

Voltage 

PWR+ 

PWR- 

EARTH 

AC 

AC Line 

AC Neutral 

Ground 

DC 

DC+ 

DC- 

Ground 

Make certain to provide adequate circuit protection by including an in-line fuse in the 
line or DC+ lead.  Suggested fuse ratings are shown in the table below. 

Power Input - Fuse Ratings 

Model 

HM1-3 

HM1-7 

HM1-23 

HM1-24 

Fuse 

0.062 A 

0.75 A 

0.25 A 

0.25 A 

3.

 

Connect the loop leads from Loop 1  (Detector 1),  Loop 2  (Detector 2), and Loop 3 
(Detector 3) to the terminals on terminal strip 1 (

TS1

) labeled 

LOOP 1

LOOP 2

, and 

LOOP 3

4.

 

The outputs of  Detectors 1, 2, and 3 terminate  on  terminal strip 2 (

TS2

).    These 

motherboard outputs connect to the inputs of the control equipment. 

Connection Configuration - Terminal Strip 2 (TS2) 

Output Type 

Output Mode 

Normally Open 

Normally Closed 

Common 

Solid-State 

Fail-Safe 

Terminal A 

— 

Terminal C 

Fail-Secure 

Terminal A 

— 

Terminal C 

Relay 

Fail-Safe 

Terminal B 

Terminal A 

Terminal C 

Fail-Secure 

Terminal A 

Terminal B 

Terminal C 

NOTE:  The Solid-State output is an Open Drain FET output with DC Common tied to Terminal C. 

MODEL HM1 SERIES 

 

3510 E. Atlanta Ave. 

Phoenix, AZ 85040 USA 

Telephone: (480) 968-6407 

Fax: (602) 437-1996 

Website: www.editraffic.com 

E-mail: [email protected] 

 

 

 

Summary of Contents for HM1 Series

Page 1: ...cluding an in line fuse in the line or DC lead Suggested fuse ratings are shown in the table below Power Input Fuse Ratings Model HM1 3 HM1 7 HM1 23 HM1 24 Fuse 0 062 A 0 75 A 0 25 A 0 25 A 3 Connect the loop leads from Loop 1 Detector 1 Loop 2 Detector 2 and Loop 3 Detector 3 to the terminals on terminal strip 1 TS1 labeled LOOP 1 LOOP 2 and LOOP 3 4 The outputs of Detectors 1 2 and 3 terminate o...

Page 2: ... table below when connected as indicated Output Type Fail SafeMode Fail SecureMode Call No Call Power Failure Loop Failure Call No Call Power Failure Loop Failure Solid State A C Open Open A C A C Open Open Open Relay B C A C B C B C A C B C B C B C A C Terminal A connected to Terminal C and no connection to Terminal B B C Terminal B connected to Terminal C and no connection to Terminal A Open no ...

Page 3: ...cluding an in line fuse in the line or DC lead Suggested fuse ratings are shown in the table below Power Input Fuse Ratings Model HM1 3 HM1 7 HM1 23 HM1 24 Fuse 0 062 A 0 75 A 0 25 A 0 25 A 11 Connect the loop leads from Loop 1 Detector 1 Loop 2 Detector 2 and Loop 3 Detector 3 to the terminals on terminal strip 1 TS1 labeled LOOP 1 LOOP 2 and LOOP 3 12 The outputs of Detectors 1 2 and 3 terminate...

Page 4: ...he table below when connected as indicated Output Type Fail SafeMode Fail SecureMode Call No Call Power Failure Loop Failure Call No Call Power Failure Loop Failure Solid State A C Open Open A C A C Open Open Open Relay B C A C B C B C A C B C B C B C A C Terminal A connected to Terminal C and no connection to Terminal B B C Terminal B connected to Terminal C and no connection to Terminal A Open n...

Reviews: