4 Operation / Normal use
4 - 10
4.6 Starting normal operation (continuation)
Step
Operation
Figure / Expl.
2b
Oil temperature and
operating temperature
The oil temperature and
operating temperature
must not exceed 110°C.
If 110°C is exceeded the
compressor will cut out
automatically.
Important!
Should the compressor
fail to cut out automati-
cally it must be switched
off immediately by hand!
2c
Operating hour meter
Various maintenance
work must be carried out
after a specified number
of operating hours.
The exact maintenance
intervals and relevant
servicing work are listed
in the maintenance
schedule.
Caution!
Observe the minimum oil and operating temperatures!
Should the operating temperature be below the dew point,
then condensation can form and become mixed with the oil.
The oil's lubricating properties are then degraded.
The consequences can be damage to the compressor through
to seizure of moving parts.
The operating temperature must be below the dew point!
Monitor normal