Equipotential bonding and Mounting

To avoid dangerous power surges (e.g. risk of fire and danger of life) the device must be earthed

• 

Use the equipotential bonding connection at the device 

(1)

.

• 

To connect the outer conductor of the coaxial cable to the equipotential bonding, use e.g. QEW earthing 

angles at the inputs and outputs of the device.

• 

Use the mounting screws included in the delivery and the mounting holes of the device 

(2)

.

  Item No. 2255279 (RF-STS-360) shown for reference only.

1

2

2

2

2

RF-Installation

• 

Connect the SAT inputs of the multiswitch to the LNBs of your SAT reception antenna. Connect the 

output signals of a CATV amplifier to the terrestrial input.

• 

Connect the subscriber ports of the multiswitch to the antenna sockets used. Use highly shielded coaxial 

cables with F connectors.

Care and cleaning

• 

Disconnect the product and allow to cool down before each cleaning.

• 

Do not use any aggressive cleaning agents, rubbing alcohol or other chemical solutions as they can 

cause damage to the housing and malfunctioning.

• 

Clean the product with a dry, fibre-free cloth.

Disposal

  Electronic devices are recyclable waste and must not be disposed of in the household waste. 

At the end of its service life, dispose of the product in accordance with applicable regulatory 

guidelines.

 

You thus fulfill your statutory obligations and contribute to the protection of the environment.

Technical data

Inputs

Number

 .................................................

5

Frequency range

 ..................................

 Return path 5 - 65 MHz

 

Terr.: 85 - 862 MHz

 

SAT.: 950 - 2200 MHz

Isolation V | H

 .......................................

25 dB

Isolation SAT inputs | SAT inputs

 ..........

30 dB

Isolation TERR | SAT

 ............................

50 dB

Subscriber ports

Number

 .................................................

 Item No. 2255278 (RF-STS-380): 8

 

Item No. 2255279 (RF-STS-360): 6

Tap loss TERR

 ......................................

20 dB

Tap loss SAT

 .........................................

 Item No. 2255278 (RF-STS-380): 9 - 3 dB

 

Item No. 2255279 (RF-STS-360): 8 - 2 dB

Isolation

 ................................................

35 dB

Max. output level SAT

 ...........................

 90 dBμV

 

(3rd order SAT EN 50083-3 35 dB KMA, 2 sender test method)

Connectors

Type

 ......................................................

F

General

Switching power supply

 ........................

90 - 250 V~ | 47 - 63 Hz | 18 V = 0.5 A

Power consumption

 ..............................

 Item No. 2255278 (RF-STS-380): 4.7 W

 

Item No. 2255279 (RF-STS-360): 4.4 W

Equipotential bonding connection

 .........

4 mm

2

Operating temperature range

 ...............

-20 to +50 °C (acc. to EN 60065)

Dimensions (W x H x D)

 .......................

approx. 275 x 125 x 50 mm

Protection class

 ....................................

IP20

Weight

 ..................................................

 Item No. 2255278 (

RF-STS-380

): 640 g

 

Item No. 2255279 (RF-STS-360): 638 g

  Visit  www.conrad.com  and  search  item  no.  for  information  about  any  optional  accessories, 

spares, or replacement parts.

Subscriber ports

Subscriber ports

TERR. input

SAT
inputs

 Operating Instructions

Multiswitch

Item No. 2255278 (RF-STS-380)
Item No. 2255279 (RF-STS-360)

Intended use

The product is suited only for distributing radio and 

television signals in the house. 
It  is  intended  for  indoor  use  only.  Contact  with 

moisture must be avoided under all circumstances.
For  safety  and  approval  purposes,  you  must  not 

rebuild  and/or  modify  this  product.  If  you  use  the 

product  for  purposes  other  than  those  described 

above,  the  product  may  be  damaged.  In  addition, 

improper use can result in short circuits, fires, electric 

shocks  or  other  hazards.  Read  the  instructions 

carefully and store them in a safe place. Make this 

product available to third parties only together with 

its operating instructions.
This product complies with the statutory national and 

European  requirements.  All  company  names  and 

product  names  are  trademarks  of  their  respective 

owners. All rights reserved.

Delivery content

• 

Multiswitch

• 

4x Mounting screws

• 

Operating instructions

Up-to-date operating instructions           

Download  the  latest  operating  instructions  at 

 

www.conrad.com/downloads  or  scan  the  QR  code 

shown. Follow the instructions on the website.

Explanation of symbols

The symbol with the lightning in the 

triangle is used if there is a risk to your 

health, e.g. due to an electric shock.
The symbol with the exclamation mark in 

the triangle is used to indicate important 

information in these operating instructions. 

Always read this information carefully.

For indoor use only.

Protection class II (double insulated).

Safety isolating transformer, short-circuit 

proof.

Safety instructions

Read the operating instructions 

carefully and especially observe 

the safety information. If you do not 

follow the safety instructions and 

information on proper handling in 

this manual, we assume no liability 

for any resulting personal injury or 

damage to property. Such cases will 

invalidate the warranty/guarantee.

a) General information

• 

The device is not a toy. Keep it out of the reach of 

children and pets.

• 

Do  not  leave  packaging  material  lying  around 

carelessly. This may become dangerous playing 

material for children.

• 

Protect the appliance from extreme temperatures, 

direct  sunlight,  strong  jolts,  high  humidity, 

moisture, flammable gases, steam and solvents.

• 

Do not place the product under any mechanical 

stress.

• 

If it is no longer possible to operate the product 

safely, take it out of operation and protect it from 

any accidental use. Safe operation can no longer 

be guaranteed if the product:

 

- is visibly damaged,

 

- is no longer working properly,

 

- has been stored for extended periods in poor 

ambient conditions or

 

- has  been  subjected  to  any  serious 

 

transport-related stresses.

• 

Please  handle  the  product  carefully.  Jolts, 

impacts  or  a  fall  even  from  a  low  height  can 

damage the product.

• 

If you have questions which remain unanswered 

by  these  operating  instructions,  contact  our 

technical  support  service  or  other  technical 

personnel.

b) Connected devices

• 

Also observe the safety and operating instructions 

of any other devices which are connected to the 

product.

c) Further safety

• 

Installation  and  repairs  to  the  equipment  may 

only  be  carried  out  by  technicians  observing 

the  current  VDE  guidelines.  No  liability  will  be 

assumed  in  the  case  of  faulty  installation  and 

commissioning.

• 

Before  handling  the  device,  pull  out  the  mains 

plug, otherwise there is danger to life. This also 

applies  if  you  clean  the  device  or  work  on  the 
connections.

• 

Only  use  the  mains  cable  connected  to  the 

device.  Never  replace  any  parts  or  make  any 

modifications  on  the  mains  cable.  Otherwise 

there is a risk of mortal injury for which we cannot 

be held liable.

• 

If a replaceable fuse is available, pull the mains 

plug before changing the fuse. Replace damaged 

fuses  only  with  standard  fuses  of  the  same 

nominal value.

• 

The  equipment  may  only  be  operated  in  dry 

rooms.  In  humid  rooms  or  outdoors  there  is 

danger  of  short-circuit  (caution:  risk  of  fire)  or 

electrocution.

• 

The mains plug is used as a disconnecting device 

from the mains voltage both during service and in 

case of danger and must therefore be reacha- ble 

and usable at all times. After connection to the 

mains, the device is in operation.

• 

To  prevent  damage  to  your  equipment  and  to 

avoid possible peripheral damages, the devices 

foreseen for wall mounting may only be installed 

on a flat surface.

• 

Choose  the  location  of  installation  or  mounting 

such  that  children  may  not  play  unsupervised 

near the equipment and its connections.

• 

The  location  of  installation  or  mounting  must 

allow a safe installation of all cables connected. 

The mains cable as well as feeder lines may not 

be damaged or clamped by objects of any kind.

• 

Absolutely  avoid  that  cables  come  near  any 

source  of  heat  (e.g.  radioators,  other  electrical 

devices, chimney, etc.).

• 

Choose the location of installation or mounting so 

that under no circumstances liquids or objects can 

get into the equipment (e.g. condensation, water 

coming from leaking roofs or flowing water, etc.).

• 

Avoid  exposure  of  the  equipment  to  direct 

sunlight and to other heat sources (e. g. radiators. 

other electrical devices, chimney, etc.).

• 

Devices  that  are  equipped  with  heat  sinks  or 

ventilation slots must under no circum-stances be 

covered or blocked. Also ensure for a generous 

air circulation around the equipment. In this way 

you avoid possible damage to the equipment as 

well as a risk of fire caused by overheating.

• 

In  case  of  damage,  interrupt  the  power  supply 

immediately.

• 

Do not try to repair the device. This device should 

only be serviced or repaired by qualified service 

personnel.  Contact  your  distributor  for  more 

information.

• 

Do not open the device.

• 

For disassembly always pull the mains plug first 

and disconnect the power supply cable from the 

connected device.

This  is  a  publication  by  Conrad  Electronic  SE,  Klaus-Conrad-Str.  1,  D-92240  Hirschau  (www.conrad.com). All  rights 

including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication 

represent the technical status at the time of printing.
Copyright 2020 by Conrad Electronic SE. 

*2255278_2255279_v1_0620_02_dh_m_en

Summary of Contents for RF-STS-380

Page 1: ...n immer aufmerksam Nur zur Verwendung in trockenen Innenbereichen Dies ist ein Gerät der Schutzklasse II Sicherheitstrenntrafo kurzschlussfest Sicherheitsanweisungen Lesen Sie die Bedienungsanleitung sorgfältig durch und achten Sie besonders auf die Sicherheitshinweise Sollten Sie die in dieser Bedienungsanleitung aufgeführten Sicherheitshinweise und Informationen für einen ordnungsgemäßen Gebrauc...

Page 2: ...iability for any resulting personal injury or damage to property Such cases will invalidate the warranty guarantee a General information The device is not a toy Keep it out of the reach of children and pets Do not leave packaging material lying around carelessly This may become dangerous playing material for children Protect the appliance from extreme temperatures direct sunlight strong jolts high...

Page 3: ... Veuillez lire ces informations attentivement À utiliser uniquement dans des locaux secs Il s agit d un dispositif de la classe de protection II Transformateur de séparation de sécurité résistant aux courts circuits Consignes de sécurité Lisez attentivement le mode d emploi et accordez une attention particulière aux consignes de sécurité Nous déclinons toute responsabilité en cas de dommages corpo...

Page 4: ... veiligheidsinstructies Als u de veiligheidsinstructies en informatie voor correct gebruik in deze handleiding niet in acht neemt dan aanvaarden wij geen aansprakelijkheid voor persoonlijk letsel of materiële schade Bovendien vervalt in dergelijke gevallen de aansprakelijkheid garantie a Algemene aanwijzingen Het product is geen speelgoed Houd het buiten bereik van kinderen en huisdieren Laat verp...

Reviews: