32
DIP-switch “T3” alarm output (alarm duration):
Time can be set between 5 seconds and 15 minutes (only
alarm zones Z1 and Z7)
Jumper position
Time
OFF
OFF
OFF
5 seconds
OFF
OFF
ON
30 seconds
OFF
ON
OFF
2 minutes
OFF
ON
ON
3 minutes
ON
OFF
OFF
5 minutes
ON
OFF
ON
8 minutes
ON
ON
OFF
12 minutes
ON
ON
ON
15 minutes
Observe the applicable statutory and community provisions! In Germany, an alarm must not exceed
3 minutes (= 180 seconds). However, this time may differ in certain communities and locations
(e.g. in spa towns).
b) Password Settings
The element “SW1” on the PCB is prepared in the factory to set an individual password for operation of
the alarm system. First set the DUP switches to “SW1” as shown in programming step <1> and change the
password in step <2> via the keypad. Then put all jumpers on “SW1” in the position OFF.
Programming Step Jumper position
<1>
ON
OFF
OFF
OFF
<2>
Press * 51234 0 UUUU #
<3>
OFF
OFF
OFF
OFF
UUUU in the table means the new password.