background image

•  To connect the external voltage/power supply, use either a power adapter with a round plug 

for the 

9-40V DC IN

 connection socket 

(2)

 or the supplied 

9-40V DC IN 

 terminal block 

(1)

 

with the screw terminals. The polarity (plus/+ and minus/-) does not need to be considered. 

The specification for the round plug can be found in the technical data.

  Only connect the power supply to one connection at a time.  Never use the terminal 

block and the connection socket with the power adapter at the same time. 

•  Switch on the external voltage/power supply. The LED operation lamp 

(3)

 lights up.

•  Connect the USB hub to the USB-B port 

(4)

 with the supplied USB cable and to a free USB 

3.0 port on your computer with the USB-A plug. The operating system recognises the new 

hardware and automatically installs the required drivers.

•  Connect your USB devices to the USB-A ports 

(5)

 of the USB hub. If a device is detected, the 

LED indicator light 

(6)

 next to the corresponding USB port lights up. 

•  There are screw threads next to the USB ports. Here you can screw on suitably equipped 

USB connectors.

Internal fuse

•  The product is protected against overcurrent with an internal fuse. The fuse is non-replaceable.
•  If the fuse trips, the product will automatically reset and will be ready for use after a few 

seconds. Make sure you find the cause of the error and fix it.

Care and cleaning

•  Disconnect the product from the power supply and connected devices before cleaning. 
•  Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these may 

damage the casing or cause the product to malfunction.

•  Do not immerse the product in water or other liquids.
•  Use a dry, lint-free cloth to clean the product.

Disposal

 Electronic devices are recyclable waste and must not be placed in household waste. 

At the end of its service life, dispose of the product according to the relevant 

statutory regulations.

 You thus fulfil your statutory obligations and contribute to environmental protection.

Technical data

a) Hub

Input voltage ............................9 – 40 V/DC
Power consumption .................max. 45 W
USB standard ..........................3.0 downward compatible
DIN attachment ........................supports rail
Max. transmission rate ............5 Gbps
USB ports ................................1x USB-B 3.0 input, 10x USB-A 3.0 output
USB output current ..................max. 900 mA per port (USB-A 3.0)
System requirements ...............Windows

®

 XP (Home, Pro, with SP1, SP2, SP3, 32-bit only),

 

Vista™ (32/64-bit), 7 (32/64-bit), 8 & 8.1 (32/64-bit), 

 

10 (32/64-bit), 10S, RT,

 

Mac OS 10.8.5 to 10.14, Linux 2.6.31.5 to 4.19

Operating conditions ................

0 to +60 °C, 10 – 90% RH

Storage conditions ...................

-20 to +85 °C, 10 – 90% RH

Dimensions (W x H x D) ..........201 x 32 x 80 mm
Weight .....................................approx. 426 g

b) Recommended power supply connector

Input voltage ............................100 – 240 V/AC
Output voltage .........................9 – 40 V/DC
Output power ...........................max. 45 W

Round plug

 ..............................external Ø 5.5 mm, internal Ø 2.1 mm L 9.5 mm

This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 

All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming or capturing in 

electronic  data  processing  systems)  requires  prior  written  approval  from  the  publisher.  Reprinting,  also  in  part,  is 

prohibited. This publication reflects the technical status at the time of printing.

Copyright 2019 by Conrad Electronic SE. 

*2161095_v1_1119_02_hk_m_en

Summary of Contents for 2161095

Page 1: ... Blockklemmen oder ein externes Netzteil im Lieferumfang nicht enthalten Das Produkt eignet sich für industrielle Anwendung und kann mit den mitgelieferten Halterungen an einer ebenen Oberfläche montiert werden Eine Verwendung ist nur in geschlossenen Räumen also nicht im Freien erlaubt Der Kontakt mit Feuchtigkeit z B im Badezimmer u ä ist unbedingt zu vermeiden Aus Sicherheits und Zulassungsgrün...

Page 2: ...stete USB Stecker festschrauben Interne Sicherung Das Produkt ist gegen Überstrom mit einer internen Sicherung geschützt Die Sicherung ist nicht austauschbar Falls die Sicherung auslöst setzt sich das Produkt automatisch zurück und ist nach einigen Sekunden wieder betriebsbereit Stellen Sie sicher dass Sie die Ursache für den Fehler finden und dieser beseitigt wird Pflege und Reinigung Trennen Sie...

Page 3: ...duct is intended for indoor use only Do not use it outdoors Contact with moisture e g in a bathroom must be avoided under all circumstances For safety and approval purposes do not rebuild and or modify this product Using the product for purposes other than those described above may damage the product In addition improper use can cause hazards such as a short circuit fire or electric shock Read the...

Page 4: ...l solutions as these may damage the casing or cause the product to malfunction Do not immerse the product in water or other liquids Use a dry lint free cloth to clean the product Disposal Electronic devices are recyclable waste and must not be placed in household waste At the end of its service life dispose of the product according to the relevant statutory regulations You thus fulfil your statuto...

Reviews: