Renkforce 1538778 Replacement Instructions Manual Download Page 19

19

1

2

15

16

•  Carefully slide the nozzle throat into the extruder as 

far as it will go (

1

).

Make sure the side of the thermistor‘s protruding cable 

s are facing to the front.

•  Fasten the nozzle throat with the grub screw and 

tighten it (

2

).

•  Reconnect the plug. 

The connector can only be connected in one direction.

17

18

•  Secure the cables of the fan and the thermistor with 

the cable tie (included in the delivery content).

•  Use the side cutter to cut the cable binding end.

•  Attach the bracket to the heatsink using the screw. 

Tighten the screw.

Summary of Contents for 1538778

Page 1: ...Serviceanleitung Thermistor mit Heizperle f r RF100 Best Nr 1538778 Seite 2 11 Replacement instructions Thermistor with heater for RF100 Item No 1538778 Page 12 21...

Page 2: ...1 Einf hrung 3 2 Symbol Erkl rung 3 3 Bestimmungsgem e Verwendung 4 4 Lieferumfang 4 5 Sicherheitshinweise 4 6 Einzelteile 6 7 Thermistor mit Heizperle wechseln 6 8 Pflege und Reinigung 11 9 Entsorgun...

Page 3: ...itergeben Heben Sie deshalb diese Serviceanleitung zum Nachlesen auf Bei technischen Fragen wenden Sie sich bitte an Deutschland www conrad de kontakt sterreich www conrad at www business conrad at Sc...

Page 4: ...rheitshinweise Aktuelle Serviceanleitungen Laden Sie aktuelle Serviceanleitungen ber den Link www conrad com downloads herunter oder scannen Sie den abgebildeten QR Code Befolgen Sie die Anweisungen a...

Page 5: ...den 3D Drucker aus und trennen Sie ihn von der Steckdose Lassen Sie den 3D Drucker und die D se auf Raumtemperatur abk hlen bevor Sie den Thermistor auswechseln Nehmen Sie sich f r den Thermistorwechs...

Page 6: ...eratur abk hlen bevor Sie den Thermistor auswechseln Ben tigtes Werkzeug 1 5 mm Innensechskantschl ssel im Lieferumfang enthalten 2 2 5 mm Innensechskantschl ssel im Lieferumfang der Best Nr 1507428 e...

Page 7: ...ckung 5 6 Nehmen Sie die Schutzabdeckung vorsichtig ab L sen Sie die Schraube an der Seite des Heizk rpers Nehmen Sie die Schraube und die Halterung ab 7 8 Schneiden Sie den Kabelbinder vorsichtig mit...

Page 8: ...s F hrungsrohr mit der D senaufnahme vorsichtig aus dem Extruder in Pfeilrichtung 11 12 L sen und entfernen Sie die beiden Madenschrauben an der D senaufnahme Ziehen Sie den Thermistor und die Heizper...

Page 9: ...2 in die kleine fffnung der D senaufnahme 1 SetzenSiedieMadenschraubeindieGewindebohrung und ziehen Sie sie fest 2 1 2 15 16 Schieben Sie das F hrungsrohr vorsichtig bis zum Anschlag in den Extruder 1...

Page 10: ...tigen Sie die Halterung mit der Schraube an dem Heizk rper Ziehen Sie die Schraube fest 19 20 Setzen Sie die Schutzabdeckung auf den Extruder Befestigen Sie die Schutzabdeckung mit der Schraube Ziehen...

Page 11: ...n Sie ein trockenes Tuch zur Reinigung des Produkts 9 Entsorgung Elektronische Ger te sind Wertstoffe und geh ren nicht in den Hausm ll Entsorgen Sie das Produkt am Ende seiner Lebensdauer gem den gel...

Page 12: ...ntroduction 13 2 Explanation of symbols 13 3 Intended use 14 4 Delivery content 14 5 Safety instructions 14 6 Component parts 15 7 Replace thermistor with heater 16 8 Cleaning and maintenance 21 9 Dis...

Page 13: ...s hints booklet for reference If there are any technical questions please contact International www conrad com contact United Kingdom www conrad electronic co uk contact 2 Explanation of symbols The l...

Page 14: ...ery content Thermistor with heater 1 5 mm hex key Cable tie Saftey instructions Up to date replacement instructions Download the latest replacement instructions at www conrad com downloads or scan the...

Page 15: ...ch off the 3D printer and disconnect it from the power supply Let the 3D printer cool down to room temperature before you start with the replacement Allocate sufficient time for the replacement proced...

Page 16: ...t Required tools 1 5 mm hex key included in delivery content 2 2 5 mm hex key supplied with item no 1507428 side cutter Use a suitable hex key to remove or tighten the screws 1 2 Switch the 3D printer...

Page 17: ...with the bracket 7 8 Cut the cable tie carefully with the side cutter Make sure that cables will not be damaged during cutting Carefully remove the plug 4 9 10 Remove the grub screw at the side of th...

Page 18: ...the heater 1 2 13 1 2 14 Insert the new thermistor 1 into the large opening of the nozzle holder 1 Make sure that the end of the thermistor is aligned with the nozzle holder Insert the grub screw into...

Page 19: ...front Fasten the nozzle throat with the grub screw and tighten it 2 Reconnect the plug The connector can only be connected in one direction 17 18 Secure the cables of the fan and the thermistor with t...

Page 20: ...otective case with the screw Tighten the screw 21 22 Insert and tighten the screw to fasten the protective cover Reconnect the power cable Switch the 3D printer on 23 Place the build bed Calibrate bui...

Page 21: ...ices are recyclable waste and must not be disposed of in the household waste At the end of its service life dispose of the product according to the relevant statutory regulations You thus fulfil your...

Page 22: ...blikation entspricht dem technischen Stand bei Drucklegung Copyright 2017 by Conrad Electronic SE This is a publication by Conrad Electronic SE Klaus Conrad Str 1 D 92240 Hirschau www conrad com All r...

Reviews: