Renkforce 1361116 Operating Instructions Manual Download Page 3

 

*) Specialist knowledge required for the installation:

 

 For the installation, in particular, the following specialist knowledge is re-

quired:

 

•   the “5 safety rules” to be followed: Switch off power; secure against 

switching back on; determine voltage-free status; earthing and short-

circuiting; cover or fence off nearby live parts

 

•   selection of the suitable tool, the meter and if necessary the personal pro-

tective equipment

 

•  evaluation of the measurement results

 

•   selection of the electrical installation material to ensure the disconnect 

conditions

 

•  IP protection types

 

•  installation of the electrical installation material

 

•   type of mains supply network (TN system, IT system, TT system) and the 

connection conditions that follow from them (classical earthing, protec-

tive earthing, required additional measures, etc.)

 

 If you do not have the expertise required for the installation, do not connect 
and install it yourself but ask a qualified technician. 

 

a) General

 

•   The unauthorised conversion and/or modification of the product is not 

permitted for safety and approval reasons (CE). Do not open/disassemble! 

It does not contain any internal parts that need to be adjusted or main-

tained by you.

 

   Maintenance, adjustment or repair work may only be carried out by an ex-

pert/authorised service centre, which is familiar with the hazards involved 

and the relevant regulations. 

 

•   The LED outdoor floodlight is not a toy and should be kept out of the reach 

of children! There is danger of a life-threatening electric shock! Install the 

LED floodlight out of the reach of children.

 

•   Caution, LED light: Do not look directly into the LED light! Do not look into 

the beam directly or with optical instruments!

 

•  The LED outdoor floodlight must not be exposed to extreme temperatures, 

strong vibrations or heavy mechanical stress.

 

•   In commercial institutions, the accident prevention regulations of the Em-

ployer’s Liability Insurance Association for Electrical Systems and Operat-

ing Facilities are to be observed!

 

•   Do not carelessly leave the packaging material lying around, since this 

may become a dangerous plaything for children.

 

•   Handle the product with care; it can be damaged by impacts, blows, or 

accidental falls, even from a low height. 

 

•   If you have any questions that are not answered in these operating in-

structions, please contact our technical department or another specialist.

 

b) Mounting location

 

•   The LED floodlight may be installed and operated indoors and outdoors. 

However, never install it in water.

 

•  Never cover the LED floodlight. The surface becomes very hot. Not only 

is there a risk of fire, but the LED floodlight may overheat, which will 

destroy it.

 

•   Only use the LED floodlight when it is firmly mounted. However, never in-

stall the LED floodlight on or inside vehicles.

 

•   Do not mount or operate the LED floodlight in rooms, or under adverse 

environmental conditions, where combustible gases, vapours or dust are 

or may be present! There is a risk of explosion!

 

•   Do not install or attach objects (e.g., decorative material) to the LED flood-

light. 

 

c) Installation, connection

 

•   The product is designed according to protection class I. The protective 

earth wire must be connected! 

 

   If there is no mains supply line with protective earthing conductor availa-

ble at the installation site, the product may not be connected and installed. 

First, draw a new mains cable with protective earth.

 

   If no protective earth is connected, faults may give rise to a danger of a 

lethal electric shock!

 

•   The LED floodlight may only operate on the mains voltage (see section 

“Technical data”). Never try to operate the product at another voltage, as 

this will result in destruction of the product.

 

•   The LED floodlight must not be connected and operated via a dimmer.

 

•   During installation, all poles must be disconnected from the mains voltage, 

e.g., via RCD. Between the RCD and the product, there must be an appro-

priately dimensioned fuse or circuit breaker (max. 16 A).

 

•   Perform installation and connection only when all supply lines are discon-

nected from the mains voltage. Otherwise, there is a risk of a life-threat-

ening electric shock!

G

  Operating instructions

  LED outdoor floodlight

 

Item no. 1361116 (28 W, cool-white)

 

Item no. 1361117 (48 W, cool-white)

 

Item no. 1361118 (77 W, cool-white)

Intended use

The LED outdoor floodlight is designed for lighting in outdoor areas, e.g. in a parking 

lot. 
Always observe the safety instructions and all other information included in these 

operating instructions!
Any use other than that described above could lead to damage to this product and 

involves the risk of short circuits, fire, electric shock, etc. No part of the product may 

be modified or converted!
This product complies with the applicable national and European legal requirements. 

All names of companies and products are the trademarks of the respective owners. 

All rights reserved.

Package contents

•  LED outdoor floodlight
•  Operating instructions

Explanation of symbols, labels

   The lightning symbol inside a triangle is used when there is a potential risk 

of personal injury, such as electric shock.

   This symbol points to specific risks associated with handling, function or 

operation. 

  The “arrow” symbol points to special tips and operating information.

  The product is not dimmable.

  Observe the operating instructions!

Safety instructions

 

 Read the complete operating introductions before using the product; the 
manual contains important information on proper installation and opera-
tion.

 

 Damages caused by failure to follow these operating instructions will void 
the warranty/guarantee! We do not assume any liability for any resulting 
damage! 

 

 We do not assume any liability for material and personal damage caused 
by improper use or non-compliance with the safety instructions! In such 
cases, the warranty will be null and void!

 

Attention, important note!

 

 This device should be installed only by people with relevant electro-tech-
nical knowledge and experience! *)

 

If it is installed improperly, 

you 

risk:

 

•  Your own life,

 

•  the life of the user of the electrical system.

 

 If it is installed improperly, 

you 

risk severe damage to property, e.g., by fire.

  

You 

face the risk of personal liability for personal injury and material dam-

age. 

 

Contact an electrician!

Summary of Contents for 1361116

Page 1: ...ma nahmen etc Haben Sie keine Fachkenntnisse f r die Montage so nehmen Sie An schluss und Montage nicht selbst vor sondern beauftragen Sie einen Fach mann a Allgemein Aus Sicherheits und Zulassungsgr...

Page 2: ...r Montage Der LED Au enstrahler kann mittels einer oder mehrerer geeigneten Schrauben ber den Halteb gel fixiert werden Zum Verstellen der Neigung des LED Au enstrahlers sind die Innensechs kantschrau...

Page 3: ...material to the LED flood light c Installation connection The product is designed according to protection class I The protective earth wire must be connected If there is no mains supply line with pro...

Page 4: ...ening into place ensure that no existing electrical cable gas or water pipes are damaged For the LED outdoor floodlight connection to power supply a suitable terminal box or socket is required both no...

Page 5: ...nt tre pr sents Risque d explosion Sur le projecteur ext rieur LED tous les objets p ex mat riel d coratif peuvent tre mont s ou attach s c Montage raccordement L appareil est construit conform ment l...

Page 6: ...ro pri es sur le support de montage Pour r gler l inclinaison du projecteur ext rieur LED desserrer l g rement les boulons Allen gauche et droite du support Veillez ne pas endommager les c bles ou con...

Page 7: ...wezig zijn of aanwezig kunnen zijn Er bestaat explosiegevaar Aan de LED Buitenschijnwerper mogen geen voorwerpen bijv decoratie materiaal worden gemonteerd of bevestigd c Montage aansluiting Het produ...

Page 8: ...Voorbereidingen op het monteren De LED Buitenschijnwerper kan met een of meerdere geschikte schroeven met be hulp van de montagebeugel worden bevestigd De zeskantschroeven links en rechts op de monta...

Reviews: