• Carefully remove the connection box from the tube.
• Open the connection box by removing the four screws.
• Loosen the strain relief by removing its screws.
• Pierce the rubber cable hole in the connection box with a
round, pointed object.
• Guide the mains cable through the hole.
10 mm
6 mm
• Remove the outer insulation on the mains cable to a maximum
length of about 16 mm. Strip the insulation on each of the three
wires on the mains cable to a length of about 6 mm. The earth
cable (yellow-green cable) should be at least 6 mm longer so
that it remains the last cable in the screw terminal in the event
of a fault.
• The neutral wire should be connected to "N", the live wire
(phase) to "L" and the protective earth to the clamping point
with the " " symbol.
• Secure the cable to the strain relief by tightening the screws.
• Close the connection box using the four screws. Ensure that
the flexible seal seals the connection box to the cover.
• Carefully slide the connection box into the tube. Ensure
that the plastic support plate keeps the connection box at a
minimum distance of 100 mm from the mounting surface.
• Secure the light to the base using the side screws.
• Unscrew the two side screws on the top using the Allen key
provided and then remove the light cover from the tube by
pulling upwards.
• Insert the light bulb (not included) into the holder (turn the light
bulb in a clockwise direction).
• Place the light cover back onto the tube. The cover can be
inserted in two different positions at 180° to each other. The
screws must fit into the grooves on the cover.
• Fix the light cover to the tube by screwing the side screws that
you previously removed into the grooves on the cover. You can
adjust the radial position of the cover slightly before securing
it by turning it when the screws are still loose.
• Turn on the power supply to the light. The light is now ready
to use.
Operation
To turn on the light, turn on the power supply corresponding to your setup method, e.g. turn on the
switch/dimmer, insert the mains plug or activate the connected switching device (infra-red sensor
switch). (These components are not included with the product.)
Replacing the light bulb
WARNING! Light bulbs get very hot when turned on and constitute a fire hazard!
Turn the light off and let the light bulb cool down for at least 10 minutes before you
replace it. Do not touch the light bulb with bare hands. Contaminants on the skin's
natural layer of fat can reduce the lifespan of the light bulb. Use a clean towel or
gloves.
• Turn off the power supply to the light.
• Remove the light cover from the tube by removing the two side screws with the Allen key
provided.
• Remove the used/defective light bulb from the light bulb socket by turning it in an anticlockwise
direction. You do not need to remove the light bulb when using the product for the first time.
• Only replace the old light bulb with a model that conforms to the specifications in the "Technical
data" section.
• Insert the new light bulb into the light bulb socket.
• Fix the light cover onto the tube using the screws that you previously removed.
• Turn on the power supply to the light.
L = brown or black
N = blue
= green / yellow
Maintenance and cleaning
Never use aggressive and abrasive detergents, rubbing alcohol or other chemical
solutions, as these could damage the casing or even impair the functioning of the
product.
• The product does not require any maintenance apart from occasionally changing the light bulb.
Leave all other maintenance or repair work to an expert. Repairs must only be carried out using
original replacement parts!
• When carrying out any work on the product (including cleaning), you must not wear metallic or
conductive jewellery such as necklaces, bracelets and rings.
• Never point a garden hose or a pressure washer etc. at the product (e.g. for cleaning)!
• Before cleaning the product, turn off the mains voltage or disconnect it from the mains; let the
lamp cool down sufficiently.
• You can use a clean, soft and dry cloth to clean the light. Dust can be easily removed using a
clean, soft paintbrush and a vacuum cleaner.
Make sure that water is always able to drain from the bottom of the tube so that
water cannot accumulate in the tube and so that the light is well-ventilated to ensure
condensation can dry.
Disposal
Electronic devices are recyclable waste and must not be disposed of in the household
waste.
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
Technical data
a) Item no. 1283501
Operating voltage.........................................220 - 240 V/AC, 50 Hz
Protection type .............................................IP44
Protection class ...........................................I
Power consumption.....................................max. 46 W
Base material................................................Die-cast aluminium
Bulb ............................................................... E27, standard bulb (max. 46 W),
LED/energy-saving bulb (max. 11 W)
Operating conditions ...................................-20 to +40 °C, 5 – 85 % RH
Storage conditions.......................................-20 to +50 °C, 5 – 85 % RH
Dimensions (W x H x D)...............................167 x 760 x 177 mm
Weight ............................................................approx. 1621 g
b) Item no. 1283502
Operating voltage.........................................220 - 240 V/AC, 50 Hz
Protection type .............................................IP44
Protection class ...........................................I
Power consumption.....................................max. 46 W
Base material................................................Die-cast aluminium
Bulb ............................................................... E27, standard bulb (max. 46 W),
LED/energy-saving bulb (max. 11 W)
Operating conditions ...................................-20 to +40 °C, 5 – 85 % RH
Storage conditions.......................................-20 to +50 °C, 5 – 85 % RH
Dimensions (W x H x D)...............................167 x 440 x 177 mm
Weight ............................................................approx. 1094 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2016 by Conrad Electronic SE.
V2_0216_02-HK