Setting
The time, date and alarm function can be set.
In setting mode, if you do not press a button for 8 seconds during a setting,
you will exit setting mode and the currently displayed value is saved.
a) Time setting
1. Keep the
MODE/SET
button (12) pressed until the hour digits flash.
2. Press the
UP
button (13) or
DOWN
button (14) to change the hour setting.
3. Press the
MODE/SET
button to confirm the setting. The minute digits flash.
4. Press the
UP
button or
DOWN
button to change the minute setting.
5. Press the
MODE/SET
button to confirm the setting.
It is not necessary to set the seconds; they are automatically reset to 00
(zero) each time the hours and minutes are set.
b) Date setting
1. Briefly press the
MODE/SET
button (12) once to change to date mode. The currently
displayed date is displayed; the
M
and
D
symbols appear on the display.
2. Keep the
MODE/SET
button pressed until the year digits flash.
3. Press the
UP
button (13) or
DOWN
button (14) to change the year setting.
4. Press the
MODE/SET
button to confirm the setting. The month digits flash.
5. Press the
UP
button or
DOWN
button to change the month setting.
6. Press the
MODE/SET
button to confirm the setting. The number of the date of the
day flashes.
7. Press the
UP
button or
DOWN
button to change the day setting.
8. Press the
MODE/SET
button to confirm the setting.
c) Alarm setting
1. Briefly press the
MODE/SET
button (12) once to change to alarm mode. The
currently set alarm time is displayed; the wake-up alarm symbol appears.
2. Keep the
MODE/SET
button pressed until the hour digits of the alarm time flash.
3. Press the
UP
button (13) or
DOWN
button (14) to change the hour setting.
4. Press the
MODE/SET
button to confirm the setting. The minute digits flash.
5. Press the
UP
button or
DOWN
button to change the minute setting of the alarm
time.
6. Press the
MODE/SET
button to confirm the setting.
Operation
a) Back-lighting of the display
1. Press the
SNOOZE/LIGHT
button (11) to light up the LCD for 5 seconds.
b) Selecting the temperature unit
1. Press the
DOWN
button (14) to change the unit of measurement of the temperature
display. Celsius or Fahrenheit is possible (°C, °F).
c) Alarm signal, snooze mode
If the wake-up signal is triggered at the set time, the wake-up alarm symbol flashes
on the LCD. The wake-up signal sounds for 2 minutes. The acoustic wake-up signal
starts with slow tones that become faster - the crescendo alarm. The wake-up signal
can be interrupted at any time (snooze function).
1. Press the
UP
button (13) to activate the alarm with the set alarm time. The wake-up
alarm symbol is displayed on the LCD.
2. Press the
SNOOZE/LIGHT
button (11) or
SNOOZE
button (16) to interrupt the alarm
for 8 minutes (snooze function).
3. Press any other button to end the wake-up signal.
d) Maximum/minimum measured values
1. Press the
MAX/MIN
button (15) to display the saved maximum values of
temperature and humidity.
2. Press the
MAX/MIN
button twice to display the minimum values.
3. Press the
MAX/MIN
button three times to return to the normal display.
The saved maximum/minimum values of temperature and humidity are reset
to zero at 00:00 (midnight).
e) 12/24 hour display
The display of the time can be selected for the 12 hour format or the 24 hour format.
1. Keep the
UP
button (13) pressed for 2 seconds to change the display format of the
time. The 24 hour format is the default setting. The symbol appears in the second
cycle of the 12 hour format.
Maintenance and cleaning
• The product does not require maintenance except for occasional cleaning. For
cleaning, use a soft, anti-static and lint-free cloth.
• Do not use abrasive or chemical cleaning agents.
• Do not immerse the product in water.
Disposal
a) Product
Electronic devices are recyclable waste and must not be disposed of in the
household waste.
At the end of its service life, dispose of the product according to the
relevant statutory regulations.
Remove any inserted (rechargeable) batteries and dispose of them
separately from the product.
b) (Rechargeable) batteries
You as the end user are required by law (Battery Ordinance) to return all used batteries/
rechargeable batteries. Disposing of them in the household waste is prohibited.
Contaminated (rechargeable) batteries are labelled with this symbol to
indicate that disposal in the domestic waste is forbidden. The designations
for the heavy metals involved are: Cd = Cadmium, Hg = Mercury, Pb = Lead
(name on (rechargeable) batteries, e.g. below the trash icon on the left).
Used (rechargeable) batteries can be returned to collection points in your
municipality, our stores or wherever (rechargeable) batteries are sold.
You thus fulfil your statutory obligations and contribute to the protection of
the environment.
Technical data
Supply voltage .....................................2 x 1.5 V/DC batteries, type AAA
Battery service life..............................approx. 6 months
Temperature display range ...............-10 to +60 °C
Humidity display range.......................20 - 90% RH
Operating conditions ..........................0 to +50 °C, 20 - 90 % RH
Storage conditions..............................0 to +50 °C, 20 - 90 % RH
Dimension (L x W x H) ........................83 x 31 x 96 mm
Weight ..................................................118 g (without batteries)
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method, e.g. photocopy, microfilming, or the capture in electronic data
processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. This publication represent the
technical status at the time of printing.
© Copyright 2014 by Conrad Electronic SE.
V2_1114_02-HK