Switching the air humidity control on or off

Briefly press the “ “ button to switch the humidity control on or off.

a)  Humidity controller is switched on            

The LED to the left of the display indicates whether the front 

socket, and thus the load, is switched on or off:
LED illuminates red:  

Off

LED illuminates green:   On
When the front socket/load is switched on, the symbol for the current operating mode is 

additionally shown between “RH” and “SET” (Air humidification  “ “ or air dehumidification “

“).

b) 

Humidity control is switched off   

    

The current air humidity is indicated at the display’s bottom left 

and the current operating mode (air humidification “

“ or air 

dehumidification “

“) is shown at the top. The LED to the left of 

the display does not light.

Functional Description

If the value falls below or exceeds the preset switching threshold, a switching 

procedure will only be performed if the measured air humidity remains above or below 

the threshold for a certain time.
This prevents the switching procedures from being performed too often if the room’s 

humidity changes rapidly.

a)  Operating mode 1 (“

“), Air humidification

This function can be used e.g. to operate an air humidifier (if the latter does not have its own 

humidity control).

Example:

•  The switching threshold is set to 60%; the air humidity drops to 50%.
• 

The air humdifier connected will be switched on until the air humidity is at or above 60% again.

• 

When the switching threshold is exceeded, the air humidifier will be switched off immediately.

•  If the air humidity drops below the switching threshold for a while (as described at the beginning, 

this prevents the peformance of many switching procedures), the air humidifier will be turned 

on again.

• 

The LED to the left of the display indicates whether the front socket, and thus the air humidifier, 

is switched on or off:

  LED illuminates red:  

Off

  LED illuminates green:  

On

b)  Operating mode 2 (“

“), Air dehumidification

This function can be used e.g. to operate an air dehumidifier (if the latter does not have its own 

humidity control) or a ventilation system.

Example:

•  The switching threshold is set to 60%; the air humidity rises to 80%.
• 

The  air  dehumidifier  connected  (or  a  ventilation  system)  will  be  switched  on  until  the  air 

humidity is below 60%.

• 

When the value falls below the switching threshold, the air dehumidifier (or a ventilation system) 

will be switched off immediately.

•  If the air humidity rises above the switching threshold for a while (as described at the beginning,  

this prevents the performance of too many switching procedures),  the air dehumidifier or the 

ventilation system will be turned on again.

•  The LED to the left of the display indicates whether the front socket, and thus the load, is 

switched on or off:

  LED illuminates red:  

Off

  LED illuminates green:   On

Maintenance and Cleaning

•  The humidity control does not require any maintenance and should never be disassembled for 

any reason. Maintenance or repairs may only be performed by qualified personnel.

•  Disconnect the humidity control from the mains socket, and disconnect the load from the 

humidity control prior to each cleaning.

•  Clean the product with a soft, clean and dry cloth. Do not press on the display too strongly, it 

could be damaged!

•  Dust can be very easily removed with a soft, clean brush and a vacuum cleaner.

Disposal

Electronic devices are recyclable waste and must not be disposed of in the household 

waste.
At the end of its service life, dispose of the product according to the relevant statutory 

regulations.

You thus fulfil your statutory obligations and contribute to the protection of the environment.

Technical data

Operating voltage.........................................230 V/AC, 50 Hz
Switching power* ........................................ 16 A, 3680 W (ohmic, resistive load) 

2 A, 460 W (inductive load)

Protection class ...........................................I
Humidity range .............................................20 – 90 % relative air humidity, not condensing
Accuracy .......................................................5 %
Inbuilt rechargeable battery ...................... 2.4 V NiMH 40 mAh accu 

(for data preservation of the preset switching threshold)

Operating temperature................................0 to +40 °C
Storage temperatur .....................................0 to +40 °C
Dimensions....................................................approx. 110 x 60 x 40 mm
Weight ............................................................approx. 137 g

* Consumers with mainly ohmic load are e.g. light bulbs, heaters etc. Consumers with inductive 

load are e.g. engines, control gears, conventional transformers, energy saving light sources etc.

These operating instructions are published by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com). 

All  rights  including  translation  reserved.  Reproduction  by  any  method,  e.g.  photocopy,  microfilming,  or  the  capture  in  electronic  data 

processing systems require the prior written approval by the editor. Reprinting, also in part, is prohibited. 
These operating instructions represent the technical status at the time of printing. Changes in technology and equipment reserved.
© Copyright 2015 by Conrad Electronic SE. 

V2_1015_02_JH

Summary of Contents for 1170728

Page 1: ...ehr möglich ist nehmen Sie das Produkt außer Betrieb und schützen Sie es vor unbeabsichtigter Verwendung Der sichere Betrieb ist nicht mehr gewährleistet wenn das Produkt sichtbare Schäden aufweist nicht mehr ordnungsgemäß funktioniert über einen längeren Zeitraum unter ungünstigen Umgebungsbedingungen gelagert wurde oder erheblichen Transportbelastungen ausgesetzt wurde Falls das Gehäuse des Prod...

Page 2: ...ber 60 liegt Bei Überschreiten der Schaltschwelle wird der Luftbefeuchter sofort ausgeschaltet Sinkt die Raumluftfeuchte für einige Zeit unter die Schaltschwelle wie zu Beginn beschrieben verhindert dies zu häufige Schaltvorgänge wird der Luftbefeuchter wieder eingeschaltet Die LED links neben dem Display zeigt Ihnen an ob die Frontsteckdose und damit der Luftbefeuchter ein oder ausgeschaltet ist ...

Page 3: ...the humidity controller or the connected device First switch off at the mains socket to which the humidity controller is connected switch off the circuit breaker Disconnect any device that is connected to the humidity control then unplug the humidity control from the mains socket Take the product to a specialist workshop or dispose of it in an environmentally friendly way In commercial institution...

Page 4: ...reshold the air dehumidifier or a ventilation system will be switched off immediately If the air humidity rises above the switching threshold for a while as described at the beginning this prevents the performance of too many switching procedures the air dehumidifier or the ventilation system will be turned on again The LED to the left of the display indicates whether the front socket and thus the...

Page 5: ...schadigd niet langer op juiste wijze werkt tijdens lange periode is opgeslagen onder slechte omstandigheden of onderhevig is geweest aan ernstige vervoergerelateerde druk Gebruik het product niet langer als de behuizing van het product beschadigd is Raak noch de luchtvochtigheidregelaar noch een daarop aangesloten apparaat aan wanneer dit nog op de netspanning is aangesloten Schakel eerst de conta...

Page 6: ...grens is op 60 ingesteld de luchtvochtigheid stijgt tot 80 De aangesloten luchtontvochtiger of een luchtverversingsinstallatie wordt zolang ingeschakeld tot de luchtvochtigheid onder 60 ligt Bij het onderschrijden van de schakelgrens wordt de luchtontvochtiger of een luchtverversingsinstallatie direct weer uitgeschakeld Stijgt de luchtvochtigheid van de omgeving enige tijd lang boven de schakelgre...

Reviews: