Renishaw RGH24 Scale Manual Download Page 2

Renishaw plc

New Mills, Wotton-under-Edge, 
Gloucestershire GL12 8JR 
United Kingdom

T

  +44 (0)1453 524524

F

  +44 (0)1453 524901

E

  [email protected]

www.renishaw.com

©  1999-2004 Renishaw plc      Issued  0904      Renishaw reserves the right to change specifications without notice

For worldwide contact details, please visit our 

main website at www.renishaw.com/contact

*M-9541-0035-03*

Load the scale into the scale guide

 

 

Remove the splitter screw (see figure 1) from the scale guide body by turning until the flats on 
the screw are parallel to the slot.

 

 

Separate the backing paper from the first 40mm of scale and feed it into the scale guide  
as shown in Figure 2 and lock in place by turning through 90°.

 

 

Relocate the splitter screw behind the backing paper as shown in Figure 2.

 

 

Push the scale carefully through to the end of scale mark, ensuring that it does not stick to the  
mounting surface until it is in position. 

   

NOTE:

 To prevent the scale sticking to the mounting surface during this operation it may be   

necessary to re-apply approximately 20 mm of backing paper to the end of the scale before  
inserting through scale guide. This can then be removed before fitting end clamps.

 

 

Attach the end of the scale to the mounting surface with light finger pressure.

Apply the scale

 

 

Traverse the axis through its full travel at a slow, steady speed.

 

 

While moving the axis apply a light finger pressure to the scale behind the scale guide  
to attach it to the mounting surface.

 

 

Gently pull the backing paper away from in front of the scale guide as it is separated.

Remove the scale guide

 

 

When the axis has reached the limit of its travel, lock the axis in place and unbolt the  
scale guide from the readhead mounting bracket.

 

 

Withdraw the scale guide along the scale whilst applying the remaining scale using  
light finger pressure.

Ensure complete adhesion

 of the scale to the mounting surface by applying firm finger pressure 

along the full length of the scale from the centre outwards to each end.

Fit end clamps

 part number A-9523-4015 (refer to Scale installation guide M-9517-2855 for details).

Scale handling precautions

Reel for lengths 
 over 1 m

Keep coils tight 

during storage

Plastic extrusion for 

lengths under 1 m

Scale surface 

is immune to 

handling

No sharp objects

Do not twist

>100 mm

DO NOT

 remove the scale for refitting or use elsewhere once it has been applied to the mounting surface.

Avoid aggressive solvents 

refer to Scale installation guide 

M-9517-2855 for details