Load the scale into the scale guide

Remove the splitter screw (see figure 1) from the scale guide body

Separate the backing paper from the first 40mm of scale and feed it into the scale
guide as shown in figure 2

Relocate the splitter screw behind the backing paper as shown in figure 2

Push the scale carefully through to the end of scale mark, ensuring that it does not
stick to the mounting surface until it is in position. 

NOTE

 to prevent the scale sticking

to the mounting surface during this operation it may be necessary to re-apply
approximately 20mm of backing paper to the end of the scale before inserting through
scale guide. This can then be removed before to fitting end clamps.

Attach the end of the scale to the mounting surface with light finger pressure

Apply the scale

Traverse the axis through its full travel at a slow, steady speed

While moving the axis

Apply a light finger pressure to the scale behind the scale guide to
attach it to the mounting surface

Gently pull the backing paper away from in front of the scale guide as it
is separated

Remove the scale guide

When the axis has reached the limit of its travel, lock the axis in place and unbolt the
scale guide from the readhead mounting bracket

Withdraw the scale guide along the scale whilst applying the remaining scale using
light finger pressure

Ensure complete adhesion

 of the scale to the mounting surface by applying firm finger

pressure along the full length of the scale from the centre outwards to each end

Fit RGC-F end clamps

 (refer to RGS-S scale installation guide for details)

DO NOT 

remove the scale for refitting or use elsewhere once it has been applied to the mounting surface.

The scale can be applied once only.

Plastic extrusion for
lengths under 6m

Scale

Keep coils tight
during storage

Straighten coils to
withdraw scale

Avoid alcohol and
solvents

Do not twist

No sharp objects

Reel for lengths
over 6m

Scale surface
is immune to
handling

>100mm

Scale handling precautions

a

b

c

dh

Renishaw reserves the right to change specifications without notice 

© 1999 Renishaw plc

Printed in England  499  Part No M-9531-1281-02 

Renishaw plc

Encoder Products Division
New Mills, Wotton-under-Edge
Gloucestershire GL12 8JR, UK
Tel:

+44 (0)1453 523 634
(07000 RENISHAW)

Fax:

+44 (0)1453 523 760

E mail

[email protected]

Internet

http://www.renishaw.com

USA

, Renishaw Inc

Tel

+1 847 843 3666

Fax

+1 847 843 1744

Japan

, Renishaw KK

Tel

+81 3 5350 2201

Fax

+81 3 5350 2207

Germany

, Renishaw GmbH

Tel

+49 712 797 960

Fax

+49 712 788 237

France

, Renishaw SA

Tel

+33 1 64 61 84 84

Fax

+33 1 64 61 65 26

Italy

, Renishaw SpA

Tel

+39 11 9 66 10 52

Fax

+39 11 9 66 40 83

Spain

, Renishaw Iberica SA

Tel

+55 11 7295 2866

Fax

+55 11 7295 1641

Switzerland

, Renishaw AG

Tel

+41 55 410 66 66

Fax

+41 55 410 66 69

Hong Kong

, Renishaw (Hong Kong) Ltd

Tel

+852 2753 0638

Fax

+852 2756 8786

Brazil

, Renishaw Latino America Ltda

Tel

+55 11 7295 2866

Fax

+55 11 7295 1641

Renishaw’s Representative Offices
People’s Republic of China, Beijing

Tel

+86 10 6461 2689

Fax

+86 10 6461 2687

Singapore

Tel

+65 438 2778

Fax

+65 438 4780

Indonesia, Jakarta

Tel/fax +62 21 424 3934

India, Bangalore

 (liaison office)

Tel/fax +91 80 224 3223

Reviews: