![Renishaw NCi-6 Installation Manual Download Page 26](http://html1.mh-extra.com/html/renishaw/nci-6/nci-6_installation-manual_1441458026.webp)
3-8
NCi-6 non-contact tool setting interface: System installation
Sharing the skip with an auxiliary probe
CNC
machine
control
Machine
power
supply
Aux . probe
output
Select M-code *
Output (probe status)
Machine skip input
* High (11 Vdc to 30 Vdc) selects the AUX probe (and may also send the start code).
Low (0 Vdc) or floating selects the NC probe.
NCi-6 connector CN2
Skip supply voltage
1
2
3
Normally open
4
Common
5
Normally closed
6
Energise (11 Vdc to 30 Vdc)
7
SSR1 voltage-free
8
SSR1 voltage-free
9
10
11
12
13
Screen
14
0 Vdc supply
15
11 Vdc to 30 Vdc supply
Auxiliary
relay