- 18 -
EN
6.2 Condensation
1. Inspect the water separator.
2. Drain any water off through the valve
(Fig. 21).
6.3 Blasting Nozzle
Replacement
1. Refer to insert no. 21-9162 for
installation.
2. Inspect for abrasive residue.
3. Inspect the seal ring position.
6.4 View Port Replacement
Please refer to the installation instructions
provided with the new pane
(insert no. 21-9811).
6.5 Sandblasting Hose
Replacement
1. Disconnect the sandblasting unit from
the compressed air supply (Fig. 5,4,3).
2. Refer to insert no. 21-9162 for the
installation instructions.
6.6 Replacing the Fluorescent
Lamp
Danger of breakage!
Do not press on the fluorescent
lamp or try to bend it when re-
placing it. We recommend using
gloves or a cloth to protect your
hands in case of breakage.
• Switch off the unit.
• Pull plug out.
• Lightly press light cover on the right side
and remove it (Fig. 8).
• Pull fluorescent lamp horizontally out of
the socket and remove it.
• Vacuum socket as thoroughly as
possible.
• Insert new fluorescent lamp in the
retainer and slide it horizontally into the
socket (Fig. 9).
• Install lamp cover in the housing on the
left side, then press it to the right until it
clicks into position (Fig. 10).
Use only original Renfert re-
placement fluorescent lamps
(see spare parts list).
6.7 Replacing the lamp cover
• Switch off the unit.
• Pull plug out.
• Lightly press lamp cover on the right
side and remove it (Fig. 8).
• Install lamp cover in the housing on the
left side, then press it to the right until it
clicks into position (Fig. 10)
7. Spare
Parts
For the order numbers of consumables
and spare parts please refer to the spare
parts list at the end of this manual.
8. Warranty
Provided the unit is properly used, Renfert
warrants all parts of the
Basic quattro
for
a
period of 3 years
. In case of any claims
for warranty original dealers‘ invoice is
required. Components subject to natu-
ral wear (e.g., blasting nozzles, hoses,
fluorescent tubes, hose connections, view
panes, filter materials, etc.) are excluded
from this warranty. The warranty is voided
in case of improper use; failure to observe
the operating, cleaning, maintenance, and
connection instructions; in case of inde-
pendent repairs or repairs by unauthor-
ized personnel; if spare parts from other
manufacturers are employed, or; in case
of unusual influences or influences not in
compliance with the utilization instructions.
Warranty service shall not extend the
original warranty.
9. Technical
Specifications
Working pressure: 1 - 6 bar [14,5 - 87 psi]
Connecting pressure, external:
6 - 8 bar [87 - 116 psi]
Air consumption:
120 l/min. at 6 bar
[87
psi]
Voltage:
230 V, 50/60 Hz
100-120 V, 50/60 Hz
Lamp power consumption:
16 W
Cable length: