Due to continuing product development, specifications are subject to change without notice

 

EV130_200_300Man_Mar13.docx  

134777_012 

 

Revised 03/2013 

 

 2013 RenewAire LLC  

Page 

4510 Helgesen Drive, Madison, WI, 53718 

608.221.4499, 800.627.4499, Fax: 608.221.2824 

[email protected]   www.renewaire.com 

 

I

NSTALLATION AND 

O

PERATION 

M

ANUAL

 

M

ODEL 

EV130\EV200\EV300 

E

NERGY 

R

ECOVERY 

V

ENTILATOR 

(ERV) 

 

 

WARNING

 

R

ISK OF 

F

IRE

,

 

E

LECTRIC 

S

HOCK

,

 OR 

I

NJURY

OBSERVE ALL CODES AND THE FOLLOWING

1.

 

Before servicing or cleaning the unit, unplug the unit line 
cord.  Make sure unit is not running before opening its 
door. 

2.

 

This installation manual shows the suggested installation 
method.  Additional measures may be required by local 
codes and standards. 

3.

 

Installation work and electrical wiring must be done by 
qualified professional(s) in accordance with all applicable 
codes, standards and licensing requirements. 

4.

 

Any structural alterations necessary for installation must 
comply with all applicable building, health, and safety 
code requirements.   

5.

 

Connect this unit only to a 120VAC grounded receptacle 
protected by a 15 or 20 amp circuit breaker.  Do not 
remove the unit’s line cord. 

6.

 

Do not install unit or controls where they can be reached 
from a tub or shower. 

7.

 

This unit must be properly ducted to the outdoors. 

8.

 

Outside air inlet for this unit must be located away from 
sources of hazardous air such as auto exhausts. 

9.

 

Sufficient air is needed for proper combustion and 
exhausting of gases through the flue (chimney) of fuel 
burning equipment that might be installed in the area 
affected by this equipment.  If this unit is exhausting air 

from a space in which chimney-vented fuel burning 
equipment is located, take steps to assure that combustion 
air supply is not affected.  Follow the heating equipment 
manufacturer’s requirements and the combustion air 
supply requirements of applicable codes and standards. 

10.

 

This unit is intended for general ventilating only.  Do not 
use to exhaust hazardous or explosive materials and 
vapors.  Do not connect this unit to range hoods, fume 
hoods or collection systems for toxics. 

11.

 

When cutting or drilling into wall or ceiling, do not 
damage electrical wiring and other hidden utilities. 

12.

 

Use the unit only in the manner intended by the 
manufacturer.  If you have questions, contact the 
manufacturer. 

 
 

CAUTION

 

1.

 

To avoid motor bearing damage and noisy and/or 
unbalanced impellers, keep drywall spray, construction 
dust, etc., out of the unit. 

2.

 

Do not connect power to the units external control 
terminals: this will damage the unit.  The external 
terminals are for use only with un-powered controls 
designed for low-voltage operation. 

 

              

 

 

EV130 (door closed) 

EV130 (door open) 

Summary of Contents for EV130 SERIES

Page 1: ...This unit must be properly ducted to the outdoors 8 Outside air inlet for this unit must be located away from sources of hazardous air such as auto exhausts 9 Sufficient air is needed for proper comb...

Page 2: ...e preferred mounting location for the unit is on a concrete foundation wall because the foundation wall will isolate any blower vibration If a basement area is not available or practical use other mec...

Page 3: ...8 round on EV300 Bathroom 4 X 10 or 6 X 10 40 to 60 sq in Kitchen 6 X 10 or 60 sq in CAUTION DO NOT PLACE ANY STALE AIR RETURNS IN GARAGES Can an ERV be used to ventilate bathrooms A RenewAire ERV can...

Page 4: ...layout on the hanging bracket is spaced for 16 19 2 and 24 on center layouts CAUTION RISK OF INJURY WHEN LIFTING UNIT AND INSTALLING IT OVERHEAD GET A HELPER AND WEAR EYE PROTECTION Installing Outsid...

Page 5: ...er to maintain good airflow Installing Controls WARNING DANGER OF ELECTRICAL SHOCK WHEN SERVICING AN INSTALLED UNIT ALWAYS UNPLUG UNIT BEFORE CONNECTING OR SERVICING CONTROLS Optional controls RenewAi...

Page 6: ...nergy exchange core two year limited warranty against defects in material and workmanship on all other components EV130 EV200 EV300 A i rf lo w R a ng e 50 140 CFM for each air stream 100 200 CFM each...

Page 7: ...ent specifications are subject to change without notice EV130_200_300Man_Mar13 docx 134777_012 Revised 03 2013 2013 RenewAire LLC Page 7 EV130 Front View Top View Right View EV200 Front View Top View...

Page 8: ...CERTIFIED RATINGS Due to continuing product development specifications are subject to change without notice EV130_200_300Man_Mar13 docx 134777_012 Revised 03 2013 2013 RenewAire LLC Page 8...

Page 9: ...n most homes for most people At this rate you will be changing the air in your home over eight times per day Most ERV systems are generally designed to provide at least this ventilation rate Be sure t...

Page 10: ...tor I Blower wheel divider side J Door assembly K Hinge set both parts L Terminal strip M Line cord with bushing N Filter set of two P Core cross bar Q Core gasket kit not shown R Hanging bracket kit...

Page 11: ...Control board with standoffs G Blower assembly complete H Motor I Blower wheel divider side J Door assembly K Hinge set both parts L Terminal strip M Line cord with bushing N Filter set of two P Core...

Page 12: ...exchange core with a soft brush attachment 3 After servicing the filters re install them see above 4 Vacuum out dust from the rest of the unit case Dust collects only on the entering faces of the ener...