INDOOR UNIT
EV
300
SPECIFICATIONS
Ventilation Type:
Static plate, heat and humidity transfer
Typical Airflow Range:
150-300 CFM
Standard Features:
Painted cabinet
Line-cord power supply
Low-voltage circuit for controls
Unit may be mounted in any orientation
Controls:
On board 24 VAC transformer/relay package
with switched dry contacts
Filters:
Total qty. 2, MERV 8, spun-polyester media:
10 1/2" x 21 3/4" x 1"
Unit Dimensions & Weight:
33 3/4" L x 24" W x 20" H
72 lbs.
Max. Shipping Dimensions & Weight (on pallet):
34" L x 44" W x 34" H
115 lbs.
Motor(s):
Qty. 1, Double-shaft standard motor
Accessories:
Backdraft damper 8"
Wall cap 8" - taupe plastic, galvanized,
paintable galvanneal
Louver with 8" round duct connection -
12" (W) x 8" (H)
Percentage timer control (PTL)
Push-button point-of-use controls (PBL), PTL req'd.
Percentage timer control with
furnace interlock (FM)
Electric duct heater - EK series (1–60 kW)
ELECTRICAL DATA
HP
Volts
HZ
Phase
Input Watts
FLA
0.2
120
60
Single
315 @ 297 CFM
3.3
UNIT PERFORMANCE
CORE PERFORMANCE
Airflow CFM
ESP in H
2
0
Temp EFF%
Total EFF%
Winter/Summer*
170
1.0
78
73/59
191
0.9
77
71/57
215
0.8
75
69/55
256
0.7
73
66/51
277
0.6
71
65/49
295
0.5
70
63/47
311
0.4
69
62/46
5 1/2"
9 1/8"
5 3/8"
9 1/4"
OA
EA
RA
FA
34" Line Cord
9 3/4" Typ.
28 3/4" Case
33 5/8" Overall
2 1/2" Typ.
24" Overall
(with Hanging
Bracket)
10" Typ.
18 5/8" Case
5/8" Typ.
2 3/8"
21 3/4" Overall (with Hanging Bracket)
To Fit
8" Duct
Typ.
20"
Overall
23 7/8" Case
22 1/4" Minimum
Service Area
(Door can be
Removed from
Hinges.)
18 1/2" Minimum
Service Area
Door
Swing
24V AC
Control
Terminal
LEFT VIEW
FRONT VIEW
RIGHT VIEW
TOP VIEW
Model: EV300
Drawing Type: Unit Dimension
Version: MAR16
ABBREVIATIONS
EA: Exhaust Air to outside
OA: Outside Air intake
RA: Room Air to be exhausted
FA: Fresh Air to inside
INSTALLATION ORIENTATION
Unit may be installed in any
orientation.
NOTE
1.UNLESS OTHERWISE SPECIFIED,
DIMENSIONS ARE ROUNDED TO THE
NEAREST EIGHTH OF AN INCH.
2.SPECIFICATIONS MAY BE SUBJECT
TO CHANGE WITHOUT NOTICE.
UNIT DIMENSIONS
EV
-SERIES & GR
AIRFLOW CONFIGURATION
Available as shown in dimension drawing.
UNIT MOUNTING & APPLICATION
Can be mounted in any orientation. RA/EA airstream
can be switched with OA/FA airstream.
STANDARD
* See HVI certification ratings on page 135 of RenewAire’s Full Line Volume XVI Catalog.